Table

Single-stage lateral lumbar interbody fusion publications.

AuthorsNumber of PatientsDesign of StudySimultaneous Lateral and Posterior Instrumentation (Parallel) or Sequential (Series)Intraoperative Imaging for Pedicle Screw PlacementTotal Operative Time (Average Minutes)Pedicle Breach RateRate of Screw Misplacement Requiring RevisionReturn to OR for Screw Revision (n)
Drazin et al13 10 (SP), 10 (DP)RetrospectiveSeriesFluoroscopy131 (SP), 190 (DP)NRNR1(SP), 0 (DP)
Blizzard et al14 72 (SP), 0 (DP)RetrospectiveSeriesFluoroscopy87.95.1%2.8% 2
Ziino et al19 42 (SP), 24 (DP)RetrospectiveSeriesFluoroscopy149 (SP), 226 (DP)NRNR2 (SP), 0 (DP)
Sellin et al15 4 (SP), 0 (DP)RetrospectiveParallelCone beam iCT138 (SP)14%14%1 (SP)
Huntsman et al20 55 (SP), 0 (DP)RetrospectiveSeriesRobotic guidance: preop CT (14 pts), fan or cone beam iCT (41 pts)155 (SP)000
Hiyama et al16 19 (SP), 26 (DP)RetrospectiveSeriesFluoroscopy98 (SP), 130 (DP)NRNRNR
Ouchida et al17 51 (SP), 51 (DP)RetrospectiveParallelFan beam iCT93 (SP), 121 (DP)9.5% (SP), 12.5% (DP)00
Buckland et al18 237 (SP), 153 (DP)RetrospectiveSeriesFlouroscopy, iCT, iCT with robotic guidance103 (SP), 306 (DP)NR1.56% (SP), 2.34% (DP)NR
  • CT, computed tomography; DP, dual position; iCT, intraoperative computed tomography; NR, not reported; SP, single position.