Journal of Korean Neurosurgical Society 2010;47(6): 446-453.
doi: https://doi.org/10.3340/jkns.2010.47.6.446
Biomechanical Changes of the Lumbar Segment after Total Disc Replacement : Charite(R), Prodisc(R) and Maverick(R) Using Finite Element Model Study.
Ki Tack Kim, Sang Hun Lee, Kyung Soo Suk, Jung Hee Lee, Bi O Jeong
Department of Orthopedic Surgery, School of Medicine, Kyung Hee University, Seoul, Korea. biojeong@khmc.or.kr
ABSTRACT
OBJECTIVE
The purpose of this study was to analyze the biomechanical effects of three different constrained types of an artificial disc on the implanted and adjacent segments in the lumbar spine using a finite element model (FEM).
METHODS
The created intact model was validated by comparing the flexion-extension response without pre-load with the corresponding results obtained from the published experimental studies. The validated intact lumbar model was tested after implantation of three artificial discs at L4-5. Each implanted model was subjected to a combination of 400 N follower load and 5 Nm of flexion/extension moments. ABAQUStrade mark version 6.5 (ABAQUS Inc., Providence, RI, USA) and FEMAP version 8.20 (Electronic Data Systems Corp., Plano, TX, USA) were used for meshing and analysis of geometry of the intact and implanted models.
RESULTS
Under the flexion load, the intersegmental rotation angles of all the implanted models were similar to that of the intact model, but under the extension load, the values were greater than that of the intact model. The facet contact loads of three implanted models were greater than the loads observed with the intact model.
CONCLUSION
Under the flexion load, three types of the implanted model at the L4-5 level showed the intersegmental rotation angle similar to the one measured with the intact model. Under the extension load, all of the artificial disc implanted models demonstrated an increased extension rotational angle at the operated level (L4-5), resulting in an increase under the facet contact load when compared with the adjacent segments. The increased facet load may lead to facet degeneration.
Key Words: Artificial disc; Lumbar spine; Finite element model; Rotation angle; Facet contact load; von-Mises stress
TOOLS
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
27
Crossref
37
Scopus
3,544
View
33
Download
Related article
Editorial Office
1F, 18, Heolleung-ro 569-gil, Gangnam-gu, Seoul, Republic of Korea
TEL: +82-2-525-7552   FAX: +82-2-525-7554   E-mail: office@jkns.or.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © Korean Neurosurgical Society.                 Developed in M2PI
Close layer