The effects of hook pattern and kyphotic angulation on mechanical strength and apical rod strain in a long-segment posterior construct using a synthetic model

Spine (Phila Pa 1976). 2001 Mar 15;26(6):627-35. doi: 10.1097/00007632-200103150-00013.

Abstract

Study design: Synthetic spine models were used to compare the effects of hook pattern and kyphotic angulation on stiffness and rod strain in long-segment posterior spinal constructs.

Objectives: To examine the biomechanical effects of hook patterns and kyphotic angulation on long-segment posterior spinal constructs.

Summary of background data: Kyphotic deformities managed by increasing rod diameter and hence construct stiffness have shown decreased postoperative loss of correction and hardware complications. The biomechanical effects of hook pattern and kyphosis are unknown.

Methods: Spine models of 0 degrees, 27 degrees 54 degrees sagittal contour, composed of polypropylene vertebral blocks and isoprene elastomer intervertebral spacers, representing T3-T12, were used for biomechanical testing of long-segment posterior spinal constructs. Models were instrumented with 6.35-mm titanium rods and one of the following hook configurations: 20-hook compression, 16-hook compression, 16-hook claw apex-empty,16-hook claw apex-full, or 8-hook claw. Construct stiffness and rod strain during axial compression were determined.

Results: The compression-hook patterns provided at least a 45% increase in construct stiffness (P = 0.013)and a 22% decrease in rod strain (P < 0.0001) compared with those obtained with the claw-hook pattern with the best biomechanical performance. When analyzing all five hook patterns, there was a 19% decrease in construct stiffness and 27% increase in rod strain when progressing from straight alignment to 27 degrees of sagittal contour (P < 0.0001). Progressing from straight alignment to 54 degrees decreased construct stiffness by 48% and increased rod strain by 55% (P < 0.0001). Construct stiffness was inversely correlated to rod strain in all five hook patterns (R2 = 0.82-0.98, P < 0.001).

Conclusions: Using compressive-hook patterns and decreasing the kyphotic deformity significantly increases construct stiffness and decreases rod strain.

MeSH terms

  • Bone Nails / standards*
  • Humans
  • Kyphosis / pathology
  • Kyphosis / physiopathology
  • Kyphosis / surgery*
  • Models, Anatomic*
  • Spinal Fusion / instrumentation*
  • Spinal Fusion / methods
  • Statistics as Topic
  • Stress, Mechanical
  • Thoracic Vertebrae / pathology
  • Thoracic Vertebrae / physiopathology
  • Thoracic Vertebrae / surgery*
  • Weight-Bearing / physiology