Early results using the Atlantis anterior cervical plate system

Neurosurg Focus. 2002 Jan 15;12(1):E13. doi: 10.3171/foc.2002.12.1.14.

Abstract

Object: The authors present a retrospective review of 77 patients in whom they performed anterior cervical discectomy and fusion (ACDF) in the treatment of radiculopathy and/or myelopathy. In all cases anterior interbody fusion was performed using the Atlantis locking plate system to treat the degenerative disease.

Methods: There were 41 men and 36 women (mean age 53.8 years), and 24 active cigarette smokers (31%) in the group. All patients presented with signs and symptoms of cervical radiculopathy and/or myelopathy, and magnetic resonance imaging or computerized tomography myelography demonstrated evidence of radicular and/or spinal cord compression at one or more cervical levels. Thirty-one patients underwent single-level ACDF, 20 patients underwent multilevel ACDF without posterior instrumentation, in eight patients one- to four-level corpectomies were supplemented with posterior fixation, 12 patients underwent single-level corpectomy, and six patients underwent multilevel corpectomy with no posterior instrumentation. The mean follow-up period was 15.33 months; overall good-to-excellent outcome was seen in 75% of patients; osseous fusion was demonstrated in 93.5%. In all patients except three, fibular allograft was used as graft material. The degree of overall cervical lordosis was measured at the last follow up and was compared with normal values obtained in age-matched individuals. In addition, the degree of cervical lordosis at fusion levels was compared with overall cervical lordosis. In patients in all five of the aforementioned categories significantly less lordosis was demonstrated than in age-matched controls. In patients who underwent single-level ACDF, single-level corpectomy, and multilevel ACDF significantly less lordosis was observed at the fusion segment than that in the overall cervical spine. Complications included one episode of chronic anterior wound drainage treated with intravenous antibiotic medication and one postoperative posterior wound infection, which required reoperation and intravenous antibiotic medication. Two cases (2.6%) of anterior screw backout and/or breakage were identified. One patient died of unrelated causes within 3 months of operation.

Conclusions: These initial results indicate that use of the Atlantis plate system for anterior cervical arthrodesis produces fusion rates and clinical outcomes that are comparable with those obtained using other locking plating systems. It has the unique advantage, however, of providing the surgeon with the choice of fixed, variable, or hybrid screw constructs as a way of tailoring screw angles to individual anatomical/biomechanical needs.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Analysis of Variance
  • Bone Plates*
  • Cervical Vertebrae / diagnostic imaging
  • Cervical Vertebrae / surgery*
  • Diskectomy / instrumentation
  • Diskectomy / methods*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Radiography
  • Retrospective Studies
  • Spinal Fusion / instrumentation
  • Spinal Fusion / methods*