[Percutaneous osteosynthesis of lumbar and thoracolumbar spine fractures without neurological deficit: surgical technique and preliminary results]

Rev Chir Orthop Reparatrice Appar Mot. 2008 Sep;94(5):456-63. doi: 10.1016/j.rco.2008.03.035. Epub 2008 Jun 3.
[Article in French]

Abstract

Purpose of the study: The aim of this work was to study the technique of percutaneous osteosynthesis of lumbar and thoracolumbar spine fractures without neurological deficit and to report preliminary results.

Material and methods: This retrospective study included 15 patients with lumbar or thoracolumbar spine fractures who were treated between January 2004 and January 2006 by percutaneous osteosynthesis. There were seven men and eight women, mean age 36 years (range 16-58 years). The Magerl classification (AO) was A1 (n=4), A2 (n=1), A3 (n=9), B2 (n=1). Levels were T12 (n=1), L1 (n=10), L2 (n=2), L3 (n=1), L4 (n=1). A specific instrument set was used to insert a short fixation using two pedicular screws on either side of the fractured vertebra and two prebent 5.5mm rods introduced with an aiming device. The operation was performed under fluoroscopy. Ten patients wore a removable corset. The upright position was allowed if there were no other injuries. Computed-tomography scans were obtained preoperatively, postoperatively and at two years follow-up. Function was assessed with the Oswestry score.

Results: Mean operative time was 108 minutes (range 40-180 minutes). None of the patients with an isolated spinal injury required blood transfusion. Mean hospital stay was 12 days (range 4-28). Results were expressed for 13 patients whose operations were exclusively percutaneous. Mean follow-up was 17 months (range 6-30). The visual analog scale (VAS) was 1.6/10. The mean Oswestry score was 16. Three quarters of the patients resumed their occupational activities. None of the patients was dissatisfied. Mean vertebral kyphosis (VK) improved from 16 to 8.1 degrees , corrected regional angle (CRA) from 12 to 2.5 degrees at last follow-up. Loss of correction at last follow-up was 1.1 degrees for VK and 2.5 degrees for CRA. The rate of pedicle screw malposition was 3.8%. There were no cases of disassembly nor material failure. There were no infections. None of the implants had to be removed.

Discussion: Percutaneous osteosynthesis of the spine is technically feasible, but requires considerable experience. Functional and subjective results have been good. The loss of correction at last follow-up has been comparable to that observed with conventional open surgery. This technique is an intermediary method between orthopaedic treatment and conventional surgery. Exact indications must be established.

Conclusion: Percutaneous osteosynthesis of lumbar and thoracolumbar spine fractures is an attractive therapeutic option. Our results are encouraging. Indications and limitations of this technique must be carefully identified.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Adolescent
  • Adult
  • Bone Screws
  • Female
  • Fluoroscopy
  • Follow-Up Studies
  • Fracture Fixation, Internal / instrumentation
  • Fracture Fixation, Internal / methods*
  • Humans
  • Length of Stay
  • Lumbar Vertebrae / injuries*
  • Male
  • Middle Aged
  • Posture
  • Retrospective Studies
  • Spinal Fractures / classification
  • Spinal Fractures / diagnostic imaging
  • Spinal Fractures / surgery*
  • Thoracic Vertebrae / injuries*
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Outcome