Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine

Eur Spine J. 2008 Nov;17(11):1476-80. doi: 10.1007/s00586-008-0776-9. Epub 2008 Sep 16.

Abstract

Segmental pedicle screw fixation is rapidly becoming a popular method of spinal instrumentation. Few studies have investigated the rates of adjacent superior segment facet joint violation. The purpose of our study were to investigate the incidence of superior segment facet joint violation after pedicle screw instrumentation in the lumbar spine and to evaluate technical factors related to the incidence. A prospective study including 96 patients who underwent lumbar and lumbosacral fusion was conducted between March 2006 and December 2007. All patients had bilateral or unilateral posterior pedicle screw-rod instrumentation with either CD-Horizon (top-loading screw) or TSRH (side-connecting screw) implants. Pedicle screws were instrumented according to the methods advocated by Roy-Camille (Group 1, 20 cases) or Weinstein (Group 2, 76 cases). All patients had computed tomography scan at 1 week post operation. CT scans were reviewed blind by an experienced spine research fellow and a consultant radiologist to determine violation of the adjacent superior segment facet joint. Superior segment facet joint violation occurred in all of the 20 patients (100%) and all of the top-level screws (100%) in Group 1. The spinal research fellow noted the incidence of facet joint violation to be present in 23.8% of the screws and 32.9% of the patients in Group 2, whereas the consultant radiologist noted this to be the case in 25.2 and 35.5%, respectively. The incidence of facet joint violation in patients with CD-Horizon screws was far lower than patients with TSRH screws (P < 0.001). In conclusion, it seems that meticulous surgical dissection without injuring the top-level facet joints, proper instrumentation of pedicle screws with the appropriate entry site (Weinstein's method), trajectory, and use of top-loading screw heads are some ways that surgeons could minimize the risk of top-level facet joint violation.

MeSH terms

  • Adult
  • Aged
  • Bone Screws / adverse effects*
  • Bone Screws / standards
  • Female
  • Humans
  • Incidence
  • Intraoperative Complications / epidemiology
  • Intraoperative Complications / physiopathology
  • Intraoperative Complications / prevention & control
  • Lumbar Vertebrae / diagnostic imaging
  • Lumbar Vertebrae / injuries*
  • Lumbar Vertebrae / surgery*
  • Male
  • Middle Aged
  • Postoperative Complications / epidemiology
  • Postoperative Complications / physiopathology
  • Postoperative Complications / prevention & control
  • Preoperative Care
  • Prospective Studies
  • Spinal Fusion / adverse effects*
  • Spinal Fusion / instrumentation
  • Tomography, X-Ray Computed
  • Young Adult
  • Zygapophyseal Joint / anatomy & histology
  • Zygapophyseal Joint / injuries*
  • Zygapophyseal Joint / surgery*