High-grade spondylolisthesis treated using a modified Bohlman technique: results among multiple surgeons

J Neurosurg Spine. 2014 May;20(5):523-30. doi: 10.3171/2014.1.SPINE12904. Epub 2014 Feb 21.

Abstract

Object: The ideal surgical management of high-grade spondylolisthesis remains unclear. Concerns regarding the original Bohlman transsacral interbody fusion technique with stand-alone autologous fibular strut include late graft fracture and incomplete reduction of lumbosacral kyphosis. The authors' goal was to evaluate the radiographic and surgical outcomes of patients treated for high-grade spondylolisthesis with either transsacral S-1 screws or standard pedicle screw fixation augmenting the Bohlman posterior transsacral interbody fusion technique.

Methods: A retrospective review of patients who underwent fusion for high-grade spondylolisthesis in which a Bohlman oblique posterior interbody fusion augmented with either transsacral or standard pedicle screw fixation was performed by 4 spine surgeons was completed. Estimated blood loss, operating time, perioperative complications, and need for revision surgery were evaluated. Upright pre- and postsurgical lumbar spine radiographs were compared for slip percent and slip angle.

Results: Sixteen patients (12 female and 4 male) with an average age of 29 years (range 9-66 years) were evaluated. The average clinical follow-up was 78 months (range 5-137 months) and the average radiographic follow-up was 48 months (range 5-108 months). Ten L4-S1 and 6 L5-S1 fusions were performed. Five fibular struts and 11 titanium mesh cages were used for interbody fusion. Six patients had isolated transsacral screws placed, with 2 (33%) of the 6 requiring revision surgery for nonunion. No nonunions were observed in patients undergoing spanning pedicle screw fixation augmenting the interbody graft. Six patients experienced perioperative complications including 3 iliac crest site infections, 1 L-5 radiculopathy without motor involvement, 1 deep vein thrombosis, and 1 epidural hematoma requiring irrigation and debridement. The average estimated blood loss and operating times were 763 ml and 360 minutes, respectively. Slip percent improved from an average of 62% to 37% (n = 16; p < 0.01) and slip angle improved from an average of 18° to 8° (n = 16; p < 0.01). No patient experienced L-5 or other motor deficit postoperatively.

Conclusions: The modified Bohlman technique for treatment of high-grade spondylolisthesis has reproducible outcomes among multiple surgeons and results in significant improvements in slip percent and slip angle. Fusion rates were high (14 of 16; 88%), especially with spanning instrumentation augmenting the oblique interbody fusion. Rates of L-5 motor deficit were low in comparison with techniques involving reduction of the anterolisthesis.

Publication types

  • Multicenter Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Blood Loss, Surgical / statistics & numerical data
  • Child
  • Female
  • Humans
  • Internal Fixators*
  • Lumbar Vertebrae / diagnostic imaging
  • Lumbar Vertebrae / surgery*
  • Male
  • Middle Aged
  • Operative Time
  • Postoperative Complications / epidemiology
  • Practice Patterns, Physicians' / statistics & numerical data
  • Radiography
  • Reoperation
  • Retrospective Studies
  • Spinal Fusion / instrumentation
  • Spinal Fusion / methods*
  • Spondylolisthesis / diagnostic imaging
  • Spondylolisthesis / surgery*
  • Treatment Outcome