A combined finite element and optimization investigation of lumbar spine mechanics with and without muscles
VK Goel, W Kong, JS Han, JN Weinstein, LG Gilbertson - Spine, 1993 - journals.lww.com
: A combined finite element and optimization approach to study the effects of muscles on the
biomechanics of the lumbar spine was initiated. Briefly, a three-dimensional, nonlinear, …
biomechanics of the lumbar spine was initiated. Briefly, a three-dimensional, nonlinear, …
Thoracolumbar burst fractures: the clinical efficacy and outcome of nonoperative management
J Mumford, JN Weinstein, KF Spratt, VK Goel - Spine, 1993 - journals.lww.com
There continues to be considerable controversy regarding the management of thoracolumbar
burst fractures. Most feel that failure of the middle osteoligamentous complex, particularly …
burst fractures. Most feel that failure of the middle osteoligamentous complex, particularly …
Prediction of load sharing among spinal components of a C5-C6 motion segment using the finite element approach
VK Goel, JD Clausen - Spine, 1998 - journals.lww.com
Study Design. A finite element model of the ligamentous cervical spinal segment was used
to compute loads in various structures in response to clinically relevant loading modes. …
to compute loads in various structures in response to clinically relevant loading modes. …
Test protocols for evaluation of spinal implants
VK Goel, MM Panjabi, AG Patwardhan, AP Dooris… - JBJS, 2006 - journals.lww.com
Prior to implantation, medical devices are subjected to rigorous testing to ensure safety and
efficacy. A full battery of testing protocols for implantable spinal devices may include many …
efficacy. A full battery of testing protocols for implantable spinal devices may include many …
Effects of charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol
VK Goel, JN Grauer, TC Patel, A Biyani, K Sairyo… - Spine, 2005 - journals.lww.com
Study Design. Finite element model of L3–S1 segment and confirmatory cadaveric testing
were used to investigate the biomechanical effects of a mobile core type artificial disc (Charité …
were used to investigate the biomechanical effects of a mobile core type artificial disc (Charité …
Effects of rigidity of an internal fixation device a comprehensive biomechanical investigation
VK Goel, TH Lim, J Gwon, JENYUH CHEN… - Spine, 1991 - journals.lww.com
Internal fixation with instrumentation often accompanies surgical fusion to augment spinal
stability, provide temporary fixation while the surgical fusion mass unites, and enhance …
stability, provide temporary fixation while the surgical fusion mass unites, and enhance …
Human lumbar vertebrae: quantitative three-dimensional anatomy
MM Panjabi, V GOEL, T OXLAND, K TAKATA… - Spine, 1992 - journals.lww.com
This study details the quantitative three-dimensional surface anatomy of human lumbar
vertebrae based on a study of 60 vertebrae. The two lower vertebrae (L4 and L5) appeared to be …
vertebrae based on a study of 60 vertebrae. The two lower vertebrae (L4 and L5) appeared to be …
Cervical human vertebrae quantitative three-dimensional anatomy of the middle and lower regions
MM Panjabi, J Duranceau, V Goel, T Oxland, K Takata - Spine, 1991 - journals.lww.com
In this study, the three-dimensional quantitative anatomy of middle and lower cervical
vertebrae was determined. The three-dimensional coordinates of various marked points on the …
vertebrae was determined. The three-dimensional coordinates of various marked points on the …
Articular facets of the human spine quantitative three-dimensional anatomy
MM Panjabi, T Oxland, K Takata, V Goel, J Duranceau… - Spine, 1993 - journals.lww.com
This study provides the quantitative three dimensional surface anatomy of the articular
facets for the entire human vertebral column based on a study of 276 vertebrae. Means and …
facets for the entire human vertebral column based on a study of 276 vertebrae. Means and …
Load-sharing between anterior and posterior elements in a lumbar motion segment implanted with an artificial disc
AP Dooris, VK Goel, NM Grosland, LG Gilbertson… - Spine, 2001 - journals.lww.com
Study Design. A nonlinear three-dimensional finite element model of the osteoligamentous
L3–L4 motion segment was used to predict changes in posterior element loads as a function …
L3–L4 motion segment was used to predict changes in posterior element loads as a function …