Test protocols for evaluation of spinal implants

…, MM Panjabi, AG Patwardhan, AP Dooris, H Serhan - JBJS, 2006 - journals.lww.com
Prior to implantation, medical devices are subjected to rigorous testing to ensure safety and
efficacy. A full battery of testing protocols for implantable spinal devices may include many …

Effects of charite artificial disc on the implanted and adjacent spinal segments mechanics using a hybrid testing protocol

…, M Shaw, R Long, D Dick, MM Panjabi, H Serhan - Spine, 2005 - journals.lww.com
Study Design. Finite element model of L3–S1 segment and confirmatory cadaveric testing
were used to investigate the biomechanical effects of a mobile core type artificial disc (Charité …

Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation

RK Ponnappan, H Serhan, B Zarda, R Patel, T Albert… - The Spine Journal, 2009 - Elsevier
BACKGROUND CONTEXT: Polyetheretherketone (PEEK) has been increasingly used as a
biomaterial for spinal implants. PEEK lumbar fusion rods have recently become available for …

Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?

H Serhan, M Slivka, T Albert, SD Kwak - The Spine Journal, 2004 - Elsevier
BACKGROUND CONTEXT: Surgeons are hesitant to mix components made of differing metal
classes for fear of galvanic corrosion complications. However, in vitro studies have failed …

Hybrid testing of lumbar CHARITE discs versus fusions

…, E Teng, Y Tominaga, G Henderson, H Serhan - Spine, 2007 - journals.lww.com
Study Design. An in vitro human cadaveric biomechanical study. Objectives. To quantify
effects on operated and other levels, including adjacent levels, due to CHARITÉ disc …

Direct Lateral Approach to Lumbar Fusion Is a Biomechanically Equivalent Alternative to the Anterior Approach: An: In Vitro: Study

CJ Laws, DG Coughlin, JC Lotz, HA Serhan, SS Hu - Spine, 2012 - journals.lww.com
Study Design. A human cadaveric biomechanical study of lumbar mobility before and after
fusion and with or without supplemental instrumentation for 5 instrumentation configurations. …

[HTML][HTML] Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation

…, VK Goel, SR Garfin, CM Bono, H Serhan… - European Spine …, 2012 - Springer
Various ball and socket-type designs of cervical artificial discs are in use or under investigation.
Many artificial disc designs claim to restore the normal kinematics of the cervical spine. …

Would CoCr rods provide better correctional forces than stainless steel or titanium for rigid scoliosis curves?

H Serhan, D Mhatre, P Newton, P Giorgio… - Clinical Spine …, 2013 - journals.lww.com
Hassan Serhan is an employee of DePuy Synthes and a stock Holder of Johnson & Johnson.
The remaining authors declare no … Other articles in this journal by Hassan Serhan, PhD …

[HTML][HTML] Biomechanics of the posterior lumbar articulating elements

HA Serhan, G Varnavas, AP Dooris, A Patwardhan… - Neurosurgical …, 2007 - thejns.org
✓The clinical success of lumbar spinal fusion varies considerably, depending on techniques
and indications. Although spinal fusion generally helps to eliminate certain types of pain, it …

Motion-preserving technologies for degenerative lumbar spine: The past, present, and future horizons

H Serhan, D Mhatre, H Defossez, CM Bono - SAS journal, 2011 - Elsevier
Over the past few decades, remarkable advancements in the understanding of the origin of