Mechanism and clinical significance of wear debris-induced osteolysis

HC Amstutz, P Campbell, N Kossovsky… - … and Related Research …, 1992 - journals.lww.com
Loosening of joint replacement components is often multifactorial. The quality of initial fixation
is very important to the outcome of the arthroplasty and is often a factor in short-term and …

Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study

…, PE Beaulé, FJ Dorey, MJ Le Duff, PA Campbell… - JBJS, 2004 - journals.lww.com
Background: Following the reintroduction of metal-on-metal articulating surfaces for total hip
arthroplasty in Europe in 1988, we developed a surface arthroplasty prosthetic system using …

[HTML][HTML] Histological features of pseudotumor-like tissues from metal-on-metal hips

P Campbell, E Ebramzadeh, S Nelson… - … and Related Research®, 2010 - Springer
Background Pseudotumor-like periprosthetic tissue reactions around metal-on-metal (MM)
hip replacements can cause pain and lead to revision surgery. The cause of these reactions …

Cobalt and chromium concentrations in patients with metal on metal total hip replacements

…, AK Skipor, PF Doorn, P Campbell… - Clinical Orthopaedics …, 1996 - journals.lww.com
There has been a resurgence of interest in the use of metal on metal bearings in total hip
arthroplasty. Although the use of metal on metal bearing couples would eliminate or …

Fracture of the neck of the femur after surface arthroplasty of the hip

HC Amstutz, PA Campbell, MJ Le Duff - JBJS, 2004 - journals.lww.com
Background: There are two main modes of failure of the femur following surface arthroplasty
of the hip: femoral neck fracture and aseptic loosening. The purpose of the present study …

Metal-on-metal hip resurfacing arthroplasty

A Shimmin, PE Beaulé, P Campbell - JBJS, 2008 - journals.lww.com
… MD, FRCSC 2 ; Campbell, Pat PhD 3 … (Reprinted, with permission, from: Campbell P,
Beaulé P, Ebramzadeh E, Le Duff M, De Smet K, Lu Z, Amstutz HC. A study of implant …

The John Charnley Award: a study of implant failure in metal-on-metal surface arthroplasties.

P Campbell, PE Beaulé, E Ebramzadeh… - … Research (1976-2007 …, 2006 - journals.lww.com
MATERIALS AND METHODS One hundred forty specimens from four metal-on-metal surface
arthroplasty designs were submitted to our implant retrieval laboratory from 1997 to 2005. …

A comparison of commercially available demineralized bone matrix for spinal fusion

…, A Alanay, D Mark, LEA Kanim, PA Campbell… - European Spine …, 2007 - Springer
In an effort to augment the available grafting material as well as to increase spinal fusion rates,
the utilization of a demineralized bone matrix (DBM) as a graft extender or replacement is …

Metal sensitivity as a cause of groin pain in metal-on-metal hip resurfacing

P Campbell, A Shimmin, L Walter, M Solomon - The Journal of arthroplasty, 2008 - Elsevier
We describe 4 patients pooled from our patient populations who presented with groin pain
at different periods postoperatively after implantation of a metal-on-metal hip resurfacing. …

Biologic and tribologic considerations of alternative bearing surfaces.

P Campbell, FW Shen, H McKellop - Clinical Orthopaedics and …, 2004 - journals.lww.com
Patients who are young or active or both who require total joint replacement pose a unique
challenge; their high activity demands wear-resistant bearings that will perform for decades, …