Does annealing improve the interlayer adhesion and structural integrity of FFF 3D printed PEEK lumbar spinal cages?
C Basgul, T Yu, DW MacDonald, R Siskey… - Journal of the …, 2020 - Elsevier
Polyaryletheretherketone (PEEK) has been commonly used for interbody fusion devices
because of its biocompatibility, radiolucency, durability, and strength. Although the technology …
because of its biocompatibility, radiolucency, durability, and strength. Although the technology …
Structure–property relationships for 3D-printed PEEK intervertebral lumbar cages produced using fused filament fabrication
C Basgul, T Yu, DW MacDonald, R Siskey… - Journal of materials …, 2018 - cambridge.org
Recent advances in the additive manufacturing technology now enable fused filament
fabrication of polyetheretherketone (PEEK). A standardized lumbar fusion cage design was 3D …
fabrication of polyetheretherketone (PEEK). A standardized lumbar fusion cage design was 3D …
The latest lessons learned from retrieval analyses of ultra-high molecular weight polyethylene, metal-on-metal, and alternative bearing total disc replacements
Knowledge regarding the in vivo performance and periprosthetic tissue response of cervical
and lumbar total disc replacements (TDRs) continues to expand. This review addresses the …
and lumbar total disc replacements (TDRs) continues to expand. This review addresses the …
Analysis of a retrieved polyethylene total disc replacement component
SM Kurtz, J Peloza, R Siskey, ML Villarraga - The spine journal, 2005 - Elsevier
BACKGROUND CONTEXT: Although total disc replacements have been performed in
Europe since the 1980s, this type of surgery is still new in the United States. The clinical …
Europe since the 1980s, this type of surgery is still new in the United States. The clinical …
Thermal localization improves the interlayer adhesion and structural integrity of 3D printed PEEK lumbar spinal cages
C Basgul, DW MacDonald, R Siskey, SM Kurtz - Materialia, 2020 - Elsevier
Additive manufacturing (AM) is a potential application for polyetheretherketone (PEEK) spinal
interbody fusion cages, which were introduced as an alternative to titanium cages because …
interbody fusion cages, which were introduced as an alternative to titanium cages because …
The biotribology of PEEK-on-HXLPE bearings is comparable to traditional bearings on a multidirectional pin-on-disk tester
D Baykal, RS Siskey, RJ Underwood… - Clinical Orthopaedics …, 2016 - journals.lww.com
Background All-polymer bearings involving polyetheretherketone (PEEK) have been proposed
for orthopaedic applications because they may reduce stress shielding, reduce weight of …
for orthopaedic applications because they may reduce stress shielding, reduce weight of …
In vivo deformation, surface damage, and biostability of retrieved Dynesys systems
A Ianuzzi, SM Kurtz, W Kane, P Shah, R Siskey… - Spine, 2010 - journals.lww.com
Study Design. Retrospective retrieval analysis. Objective. To evaluate wear, deformation
and biodegradation within retrieved polycarbonate urethane (PCU) components of Dynesys …
and biodegradation within retrieved polycarbonate urethane (PCU) components of Dynesys …
Morphology and crystalline architecture of polyaryletherketones
M Reitman, DJ Jaekel, R Siskey, SM Kurtz - PEEK biomaterials handbook, 2019 - Elsevier
The properties of polyetheretherketone (PEEK) are the direct result of the chemistry and
architecture of the polymer backbone, the manner and extent to which the molecules organize …
architecture of the polymer backbone, the manner and extent to which the molecules organize …
Deformation of metal-backed acetabular components and the impact of liner thickness in a cadaveric model
Shell deformation of resurfacing and all-metal modular cups following press-fit implantation
has been reported, but not for conventional metal-backed cups with polyethylene liners. The …
has been reported, but not for conventional metal-backed cups with polyethylene liners. The …
Retrieval analysis of a ProDisc-L total disc replacement
TJ Choma, J Miranda, R Siskey, R Baxter… - Clinical Spine …, 2009 - journals.lww.com
Study Design We retrieved a functioning ProDisc-L total disc replacement and associated
tissues at 16 months of service life. Objective To analyze a previously unreported mode of …
tissues at 16 months of service life. Objective To analyze a previously unreported mode of …