Trabecular bone microdamage and microstructural stresses under uniaxial compression
S Nagaraja, TL Couse, RE Guldberg - Journal of biomechanics, 2005 - Elsevier
The balance between local remodeling and accumulation of trabecular bone microdamage
is believed to play an important role in the maintenance of skeletal integrity. However, the …
is believed to play an important role in the maintenance of skeletal integrity. However, the …
Quantitative microcomputed tomography analysis of mineralization within three‐dimensional scaffolds in vitro
Synthetic and naturally derived scaffold biomaterials in combination with osteogenic cells or
bioactive factors have the potential to serve as bone graft substitutes. Porous poly(l‐lactide‐…
bioactive factors have the potential to serve as bone graft substitutes. Porous poly(l‐lactide‐…
Age-related changes in trabecular bone microdamage initiation
With age, alterations occurring in bone quality, quantity, and microarchitecture affect the
resistance of trabecular bone to local failure. The clinical implications of these changes are …
resistance of trabecular bone to local failure. The clinical implications of these changes are …
The role of computational modeling and simulation in the total product life cycle of peripheral vascular devices
…, ML Dreher, S Nagaraja… - Journal of …, 2017 - asmedigitalcollection.asme.org
The total product life cycle (TPLC) of medical devices has been defined by four stages:
discovery and ideation, regulatory decision, product launch, and postmarket monitoring. …
discovery and ideation, regulatory decision, product launch, and postmarket monitoring. …
The effects of bone microstructure on subsidence risk for ALIF, LLIF, PLIF, and TLIF spine cages
…, S Nagaraja - Journal of …, 2019 - asmedigitalcollection.asme.org
Several approaches (anterior, posterior, lateral, and transforaminal) are used in lumbar
fusion surgery. However, it is unclear whether one of these approaches has the greatest …
fusion surgery. However, it is unclear whether one of these approaches has the greatest …
Relationships of quantitative ultrasound parameters with cancellous bone microstructure in human calcaneus in vitro
KA Wear, S Nagaraja, ML Dreher… - The Journal of the …, 2012 - pubs.aip.org
Ultrasound parameters (attenuation, phase velocity, and backscatter), bone mineral density (BMD),
and microarchitectural features were measured on 29 human cancellous calcaneus …
and microarchitectural features were measured on 29 human cancellous calcaneus …
[HTML][HTML] Effects of oxide layer composition and radial compression on nickel release in nitinol stents
…, K Miyashiro, C Trépanier, S Nagaraja - Shape Memory and …, 2015 - Springer
There is a public health need to understand the effects of surface layer thickness and
composition on corrosion in nickel-containing medical devices. To address this knowledge gap, …
composition on corrosion in nickel-containing medical devices. To address this knowledge gap, …
High compressive pre-strains reduce the bending fatigue life of nitinol wire
Prior to implantation, Nitinol-based transcatheter endovascular devices are subject to a complex
thermo-mechanical pre-strain associated with constraint onto a delivery catheter, device …
thermo-mechanical pre-strain associated with constraint onto a delivery catheter, device …
Impact of nitinol stent surface processing on in-vivo nickel release and biological response
S Nagaraja, SJL Sullivan, PR Stafford, AD Lucas… - Acta biomaterialia, 2018 - Elsevier
Although nitinol is widely used in percutaneous cardiovascular interventions, a causal
relationship between nickel released from implanted cardiovascular devices and adverse …
relationship between nickel released from implanted cardiovascular devices and adverse …
The effects of surface processing on in-vivo corrosion of Nitinol stents in a porcine model
…, K Miyashiro, ML Dreher, C Trépanier, S Nagaraja - Acta Biomaterialia, 2017 - Elsevier
A major limitation with current assessments of corrosion in metallic medical devices is the lack
of correlation between in-vitro and in-vivo corrosion performance. Therefore, the objective …
of correlation between in-vitro and in-vivo corrosion performance. Therefore, the objective …