A review of the biologic effects of spine implant debris: Fact from fiction
NJ Hallab - SAS journal, 2009 - Elsevier
BACKGROUND: Biologic-reactivity to implant-debris is the primary determinant of long-term
clinical performance. The following reviews: 1) the physical aspects of spinal-implant debris …
clinical performance. The following reviews: 1) the physical aspects of spinal-implant debris …
Orthopedic implant cobalt‐alloy particles produce greater toxicity and inflammatory cytokines than titanium alloy and zirconium alloy‐based particles in vitro, in …
A Dalal, V Pawar, K McAllister… - Journal of Biomedical …, 2012 - Wiley Online Library
The performance of total joint arthroplasty (TJA) depends on the size/shape, material, and
amounts of implant debris. Much remains unknown in terms of which types of debris are …
amounts of implant debris. Much remains unknown in terms of which types of debris are …
Macrophage reactivity to different polymers demonstrates particle size‐ and material‐specific reactivity: PEEK‐OPTIMA® particles versus UHMWPE particles in the …
NJ Hallab, K McAllister, M Brady… - Journal of Biomedical …, 2012 - Wiley Online Library
Biologic reactivity to orthopedic implant debris is generally the main determinant of long‐
term clinical performance where released polymeric particles of Ultra‐high molecular weight …
term clinical performance where released polymeric particles of Ultra‐high molecular weight …
Quantifying subtle but persistent peri-spine inflammation in vivo to submicron cobalt–chromium alloy particles
NJ Hallab, FW Chan, ML Harper - European Spine Journal, 2012 - Springer
Purpose We evaluated the consequences of cobalt–chromium alloy (CoCr) wear debris
challenge in the peri-spine region to determine the inflammation and toxicity associated with …
challenge in the peri-spine region to determine the inflammation and toxicity associated with …
Characterizing fretting damage in different test media for cardiovascular device durability testing
In vitro durability tests of cardiovascular devices are often used to evaluate the potential for
fretting damage during clinical use. Evaluation of fretting damage is important because …
fretting damage during clinical use. Evaluation of fretting damage is important because …
Metal Ion Sensitivity
WM Mihalko, CR Olinger - Handbook of Spine Technology, 2021 - Springer
Metal hypersensitivity to biomaterial alloys have been reported since the 1970s. While most
reports have been in the total joint literature, in the last 10 years isolated spinal implant …
reports have been in the total joint literature, in the last 10 years isolated spinal implant …
[CITATION][C] Zkoušení a hodnocení korozní odolnost vybraných kovových biomateriálů
J Hlinka - 2013 - dspace.vsb.cz
Tato diplomová práce si klade za cíl představit základní skupiny biomateriálů, jejich primární
použití a poukázat jak na jejich výhody, tak jejich nevýhody. Jsou zde také diskutovány …
použití a poukázat jak na jejich výhody, tak jejich nevýhody. Jsou zde také diskutovány …