Learns more about the ioverame dials branch treatments

Effect of Modified Assisted Reduction and Internal Fixation System on Chronic Pain and Long-term Prognosis After Isthmic Spondylolisthesis Surgery: A Randomized Controlled Study

  • International Journal of Spine Surgery
  • June 2026,
  • 20
  • (3)
  • 339-348;
  • DOI: https://doi.org/10.14444/8872

Abstract

Background This study prospectively investigated the clinical significance of the modified assisted reduction and internal fixation system in relieving chronic pain following isthmic spondylolisthesis surgery.

Methods In total, 58 patients with isthmic spondylolisthesis were randomly divided into the observation group and control group. Twenty-eight patients belonged to the observation group (application of modified assisted reduction and internal fixation system) and 30 patients belonged to the control group (application of traditional posterior reduction and internal fixation system). All patients received regular postoperative rehabilitation treatment. The pre- and postoperative degree of spondylolisthesis and intervertebral height were compared between the 2 groups. Visual analog scale and Oswestry Disability Index scores for each patient were collected. The rates of fusion and implant-related complications were also assessed.

Results Baseline characteristics and operation conditions of the 2 groups were similar. There was no significant difference between the 2 groups in the mean visual analog scale scores for low back pain (2.1 vs 2.8, P > 0.05, |d| = 0.38) and radicular symptoms (1.7 vs 2.0, P > 0.05, |d| = 0.38) or Oswestry Disability Index scores (18.6% vs 22.5%, P > 0.05, |d| = 0.38) at 12 months, Cohen’s d effect size analysis indicated small effects for all. Among various radiological measurement indicators, the observation group performed better than the control group, with statistically significant differences in the mean height of intervertebral space (11.4 vs 10.0, P < 0.05) and the mean degree of spondylolisthesis (9.6 vs 18.4, P < 0.05) observed at 12 months. During the 12-month follow-up, the fusion rate of the control group was 76.7%, and that of the observation group was 85.7% (P > 0.05). The observation group did not report any implant-related complications, whereas the control group identified 1 case of pedicle screw loosening and 1 case of pedicle screw fracture, leading to a total complication rate of 6.67% (P < 0.05).

Conclusion The modified assisted reduction and internal fixation system has clinical value in alleviating postoperative chronic pain and improving long-term prognosis in patients with isthmic spondylolisthesis.

Clinical Relevance This modified treatment method can effectively enhance the surgical outcomes for patients with isthmic spondylolisthesis.

Level of Evidence 2.

Introduction

Isthmic spondylolisthesis (IS) is caused by a discontinuity in the isthmic bone between the superior and inferior articular processes of the lumbar vertebral arch and gradually develops under the influence of various factors, including lumbar biomechanics.1,2 IS typically results in symptoms such as lower back pain, intermittent claudication, and cauda equina syndrome, significantly affecting the quality of life of patients.2 Surgical intervention is recommended when persistent lower back pain occurs and conservative treatment proves ineffective.3 Although most patients benefit from surgery, some patients have less than expected postoperative outcomes and persistent, recurrent, or progressive axial pain and/or limb pain.4,5 With the growing number of posterior lumbar spine surgeries, the incidence of postoperative chronic pain increases gradually.6 Previous studies have found that the occurrence of postoperative chronic pain is related to various factors, including age, smoking, type of pain, revision surgery, surgical technique, quality of life, and psychological state.7 Among these, surgical technique is the most important factor.7 Therefore, to alleviate postoperative chronic pain and improve long-term prognosis, the development of effective surgical technique improvement plans is urgently needed.

At present, the common treatment methods for IS include posterior decompression, pedicle screw fixation, reduction, and interbody fusion, which have achieved satisfactory clinical outcomes.8 The purpose of reduction is to normalize the sagittal sequence of the lumbar vertebrae and achieve biomechanical balance, which helps to improve fusion rates, enhance radiological reduction of slippage, and shorten hospitalization time.9 However, during the attempt to reduce the sliding vertebral body, it is often necessary to apply a considerable amount of traction to overcome the resistance of soft tissues and the effects of gravity.10 This powerful traction is transmitted through the connecting rod to the pedicle screw itself, generating significant shear stress between the screw and the vertebral bone, which may lead to screw loosening or fracture, thereby affecting the stability of the internal fixation system and influencing spinal fusion.10 Clancy et al indicated that the loosening or improper positioning of such surgical instruments may be one of the causes of postoperative chronic pain.11 To address these issues, our team has improved the reduction and internal fixation system. Moreover, the concept of assisted reduction has been proposed, along with a redesign of the intervertebral traction device.

In aiming to evaluate the clinical significance of the modified assisted reduction and internal fixation system for the treatment of IS to alleviate postoperative chronic pain, we have designed a prospective observational study including 58 IS patients. Postoperative visual analog scale (VAS) score, Oswestry Disability Index (ODI) score, intervertebral height, degree of spondylolisthesis, fusion rate, and surgery-related complications were compared. These outcome measures have been observed to (1) evaluate the clinical significance of an improved internal fixation and reduction system for the treatment of IS; (2) estimate the impact of radiological findings and imaging features; and (3) explore the complications after lumbar spine surgery with a modified assisted reduction and internal fixation system.

Materials and Methods

This study was approved by the Ethics Committee of Harrison International Peace Hospital and the Chinese Clinical Trials Registry (trial registration number: ChiCTR-ONC-17014090).

Participants: Inclusion and Exclusion Criteria

Patients with IS who underwent modified assisted reduction and internal fixation (study group) or traditional posterior lumbar spine surgery (control group) between December 2017 and April 2020 at the authors’ hospital were sought for inclusion in the present study. The inclusion criteria were as follows: (1) all patients underwent x-ray, computed tomography, and magnetic resonance imaging examinations and were clinically diagnosed with IS; (2) all cases were classified according to the lumbar surgery level as L3 to L4, L4 to L5, and L5 to S1 with Meyerding grades II° to IV°; (3) the observation group received posterior lumbar spine surgery using the modified assisted reduction and internal fixation system, the control group received traditional posterior lumbar spine surgery; (4) all patients had complete follow-up data, including VAS score, ODI score, intervertebral height, degree of spondylolisthesis, fusion rate, and surgical-related complications. Exclusion criteria were as follows: (1) history of severe lumbar spine trauma; (2) history of serious heart, liver, lung, and brain diseases; and (3) patients unable to cooperate with clinical management and postoperative follow-up. All patients were included in the postoperative evaluation until the latest examination in this study. Written informed consent was obtained from all volunteer participants prior to enrollment.

Research Methods

Preoperative Planning

A team of experienced spinal surgeons conducted all the lumbar spine surgeries involved in the study. According to the preoperative plan, patients were placed in the prone position under general anesthesia with a posterior approach to the lumbar spine, decompression, titanium screw fixation, reduction, interbody bone grafting (using polyetheretherketone cages), and interbody fusion. The observation group utilized a modified assisted reduction and internal fixation system, while the control group employed a traditional pedicle screw system.

Surgical Technique

As an example of the L5 to S1 surgical approach in the reduction and fixation of pedicle screws, the surgical process was as follows: the L3 to S2 spinal exposure was achieved through a standard posterior midline lumbosacral approach. Decompression was performed via total laminectomy, removing the vertebral arch of L5 and pre-existing scar tissue. This was done to thoroughly decompress the neurological elements and to clearly visualize the L5 nerve roots. Two pedicle screws (which played the role of reducing) were inserted into the L5 vertebral body. Screws used to secure the vertebral body are inserted into S1. The annulus fibrosus was carefully excised, and the nucleus pulposus was removed. For the control group patients, traditional pedicle screws were applied with dorsal force to the L5 vertebra for reduction. After the reduction, the L5 to S1 segment was expanded by the conventional pedicle screw system, and an appropriate cage was introduced into the intervertebral space.

For the observation group patients, modified pedicle screws were inserted into the vertebral body (Figure 1). Subsequently, the appropriate modified interbody distractor was inserted into the intervertebral space, parallel to the intervertebral direction (Figure 2). The modified interbody distractor was slowly rotated 90° to achieve intervertebral distraction, and the height of the intervertebral space was recovered. Reduction was performed by the posteriorly applied force of the newly developed pedicle screw in the L5 vertebral body. In this process, the modified interbody distractor acted as the fulcrum, and reduction of the L5 vertebral body was performed by following the slide of the modified distractor. The reduction was maintained by provisionally locking the pedicle screw/rod construct. Next, a suitable cage was introduced into the intervertebral space, and this strengthened designed reduction and fixation system was compressed and permanently locked.

Figure 1

The modified internal fixation system (A) comprised 13 strengthened designed parts (1–13): widened self-tapping threaded reduction and fixation pedicle screw; connecting rod with physiological curvature; coaxial compression and anti-spin tooth for reduction, and others. (B) The design of the modified internal fixation system was specially used for the reduction of spondylolisthesis, which is applied to solve the problem of reduction failure in operations.

Figure 2

The modified intervertebral distractor. the titanium alloy distractor has a modified design of a single-sided slide-rail. And the fundamental consideration in the conception of a solution plan is not only the function of intervertebral distraction but also assisted reduction.

Postoperative Management

Cefuroxime of 1.5 g intravenous infusion was administered to all patients during the operation and per 12 hours after surgery for 24 hours. The drainage tube should be removed when the drainage flow is less than 50 mL. The wound dressing was changed every other day, and the suture was removed in 10 to 12 days.

Exercise Rehabilitation

Exercise rehabilitation was performed 1 week after surgery, and the same rehabilitation physician team was assigned to guide the patient’s rehabilitation. The patients of the 2 groups primarily adopted an active exercise rehabilitation method: (1) supine straight leg lifting exercise for 10 seconds was gradually used to build strength in the quadriceps, and each leg practiced 30 movements per day; (2) support the body through the head, elbows, and heels in the prone position for 3 seconds to cure lumbar muscle atrophy and core strength weakness, conducted 30 times per day; (3) unilateral lumbosacral and pelvic lifting exercise for 10 seconds in standing position, taking turns on both sides for a total of 30 times per day. The purpose of these exercises was to improve the excessive pelvic anterior tilt and increase walking stability.

Follow-up

Clinical follow-up was arranged at regular intervals. The patients were evaluated monthly for 3 months, followed by 3-month intervals for the remainder of the first year after surgery, with subsequent follow-up occurring every 6 months. Clinical assessments were performed at each visit. Anteroposterior and lateral lumbar x-rays were obtained at 3, 6, and 12 months after surgery, with additional flexion-extension dynamic lumbar x-rays taken at 12 months. The fixation system was radiologically assessed, and the rate of fracture and loosening was calculated.

Evaluation Indicators

Clinical Outcome Evaluation

The self-administered VAS and ODI health questionnaires were assessed to measure changes in pain and functional status from preoperative to postoperative and follow-up periods.

Radiological Measurement

The height of the intervertebral space and the degree of spondylolisthesis were measured using Adobe Photoshop CS5 (Adobe Systems Incorporated, California, USA). To fairly assess the margins of the vertebral body, the margins were measured 3 times, and a mean length was determined. Radiological results of fusion were observed at 1-year follow-up. The same investigator performed all computerized measurements.

Height of the Intervertebral Space

Intervertebral height is the longitudinal space supported by the disc or the cage through the operation. The height of the intervertebral space was measured at its maximal point along the intervertebral space. This method of measurement has been described elsewhere.12 The intervertebral height was measured according to the Tallard method13 (Figure 3).

Figure 3

Measurement of intervertebral height and degree of spondylolisthesis.

Degree of Spondylolisthesis

The degree of spondylolisthesis was mainly used to measure the slippage between the upper and lower vertebral bodies. The degree of spondylolisthesis was measured according to the Meyerding method.13 The lateral x-ray film was applied to divide the degree of spondylolisthesis. The Meyerding classification was based on the percentage of sliding vertebra corresponding to its adjacent lower vertebral body. Grade I is less than 25%, grade II is between 25% and 49%, grade III is between 50% and 74%, and grade IV is greater than 75%. The degree of spondylolisthesis was subsequently expressed as a percentage of the inferior endplate diameter to normalize against small changes in radiographic technique14,15 (Figure 3).

Assessment of Fusion

Flexion-extension dynamic lumbar x-rays were used to assess intervertebral fusion at 12-month follow-up for each patient. Evaluation methodology for intervertebral fusion is (1) formation of an intervertebral bone bridge; (2) the density of the bone graft did not decrease or increase; (3) the height of the intervertebral space was maintained; and (4) no x-ray transparent band around the cage. The high bone-graft fusion rate has clinical significance and effects of maintainable postoperative stability, intervertebral height, and physiological lumbar curvature.

Postoperative Complications

Postoperative complications were recorded, and internal fixation follow-up was performed. Fracture or loosening of internal fixation was evaluated based on radiological features and change in position.

Statistical Analysis

SPSS version 20.0 software (SPSS Inc., Chicago, IL, USA) was used to compute statistical analysis of the results. The study includes count data and quantitative data. The quantitative data were presented as mean ± SD. The χ 2 test was applied to compare the count data of gender, surgery level, VAS score, ODI score, Meyerding grade, complications, and fusion rate. The Student t test was used to compare differences on quantitative data of age, duration, hospitalization, operation time, intraoperative bleeding, drainage volume, and intervertebral height. The P value of <0.05 was considered statistically significant.

Results

Between December 2017 and April 2020 at the authors’ hospital, 28 patients with IS received modified assisted reduction and internal fixation, and 30 patients with IS received traditional posterior lumbar spine surgery as a control. There were 15 men and 43 women with a mean age of 51.2 ± 11.6 years, ranging from 39 to 65 years. There were 7 men and 21 women in the observation group; their ages ranged from 39 to 63 years with a mean of 50.9 years. Meyerding grades were as follows: 17 cases of II, 10 cases of III, and 1 case of IV. In the control group, there were 8 men and 22 women; the ages ranged from 41 to 65 years, with a mean of 52.5 years. Meyerding grades were as follows: 18 cases of II, 11 cases of III, and 1 case of IV (Table 1).

View this table:
Table 1

Baseline characteristics of the patients.

General Information

Follow-up duration was 18 ± 6.6 months; it ranged from 12 to 36 months for all patients. There was no significant difference between the observation group and the control group in hospitalization length, operation time, intraoperative bleeding, and postoperative drainage (P > 0.05; Table 2).

View this table:
Table 2

Conditions of operation (mean ± SD).

Clinical Outcome Evaluation

Visual Analog Scale

Statistical analysis showed significant improvements in pain on the postoperative VAS scores (P < 0.05) compared with the preoperative status among all groups. Early pain relief was successful in 93.1% of the patients. However, there was no significant difference between the 3 months and 12 months within each group (P > 0.05). There were no statistically significant differences in the VAS for radicular symptoms and low back pain between the control and observation groups at each time point (P > 0.05). However, Cohen’s d effect size analysis indicated that both groups exhibited small effect sizes in VAS scores for radicular symptoms (|d| = 0.21) and low back pain (|d| = 0.38; Table 3). In addition, 3 cases of severe low back pain (VAS ≥ 7) occurred in the observation group, all of which were treated with prescribed oral analgesics.

View this table:
Table 3

VAS scores (mean ± SD) of 2 groups.

Oswestry Disability Index

The mean preoperative ODI score was 55.9% ± 14.7% and improved to 36.1% ± 17.2% at 3 months after surgery in patients of the control group and 22.5% ± 13.6% at 12 months. The mean preoperative ODI score was 58.8% ± 19.1% in patients in the observation group and improved to 30.9% ± 15.8% at 3 months after surgery and 18.6% ± 11.2% at 12 months. For both the observation and control groups, the ODI score showed improvement from baseline at the 3- and 12-month follow-up visits (P < 0.05). There were no statistically significant differences in the ODI score for low back pain between the control and observation groups (P > 0.05). Cohen’s d effect size analysis indicated a small effect between the 2 groups at the 12-month follow-up (Table 4).

View this table:
Table 4

ODI scores of 2 groups (mean ± SD).

Radiological Measurement

Intervertebral Height

In the control group, the mean preoperative height of the intervertebral space was 6.0 ± 1.9 mm. The mean postoperative intervertebral height was 11.2 ± 1.6 mm at 3 months after surgery and 10.0 ± 1.2 mm at 1-year follow-up. In the observation group, the mean preoperative intervertebral height was 5.5 ± 1.7 mm. The mean postoperative intervertebral height was 11.6 ± 1.4 mm at 3 months after surgery and 11.4 ± 1.3 mm at 1-year follow-up. The observation group had a higher intervertebral space at 1-year follow-up than the control group, and the difference was statistically significant (P < 0.05; Table 5).

View this table:
Table 5

Radiological measurement (mean ± SD) of 2 groups.

Degree of Spondylolisthesis

The mean preoperative degree of anterior displacement was 46.7% ± 15.1% in the control group. After surgery, the mean degree of anterior displacement was 16.5% ± 10.6% at 3 months and 18.4% ± 11.1% at 1-year follow-up. The mean preoperative degree of spondylolisthesis was 46.0% ± 16.6% in the observation group. After surgery, the mean degree of anterior displacement was 9.6% ± 4.1% at 3 months after surgery and 9.9% ± 4.4% at 1-year follow-up. A statistically significant improvement was observed in the observation group compared with the control group (P < 0.05; Table 5; Figure 4).

Figure 4

Analysis of the radiological performance of 2 groups. (A) Female patient, age 65 y, in the control group; preoperative image shows grade III L5 spondylolisthesis. (B) Radiological findings of surgical therapies, including reduction and fusion, are discouraging at 12-mo postoperative review. (C) Female patient of the observation group, age 62 y; preoperative radiograph showing grade III L5 spondylolisthesis. (D) Postoperative radiological results suggest that reduction and fusion are satisfactory at 12-mo follow-up.

Assessment of Fusion

In the control group, the fusion rate was 76.7% at 1-year follow-up. The fusion rate of the observation group was 85.7% at 1-year follow-up. The observation group had a higher fusion rate than the control group, whereas the results were not statistically significant (P > 0.05).

Complications

At 6-month follow-up, 1 case of pedicle screw loosening occurred in the control group. At 12-month follow-up, 1 case of pedicle screw fracture occurred in the control group. The overall rate of fracture and loosening of the fixation system was 6.67%. No fracture or loosening of the fixation system was observed in the observation group. These differences were statistically significant (P < 0.05).

Discussion

Postoperative chronic pain has always been a significant factor contributing to poor postoperative outcomes in IS patients, severely affecting the quality of life of patients and imposing a heavy burden of illness.16 Despite the availability of various treatment options for postoperative chronic pain at present, exploring effective measures remains a challenging and unresolved medical issue.17 In this study, the author and the codevelopment team were involved in the development of a modified assisted reduction and internal fixation system research project. These clinical and radiology results showed that modified assisted reduction and internal fixation systems have positive effects in relieving chronic pain and improving long-term prognosis after IS surgery.

Theoretical Advantages of the Modified Assisted Reduction and Internal Fixation System

In the traditional lumbar spondylolisthesis reduction and internal fixation system, vertebra reduction uses 2 screw-rod-based methods. One is the short-segment screw-rod traction method: implant screws in the slipped/adjacent vertebrae connect with a rod and tighten nuts to pull the vertebra back via rod rigidity.18 During the process, the screws bear significant axial tension, which may lead to screw loosening or pullout.19 The other method is to fix distal vertebral screws, attach a pre-bent lordotic rod, then tighten proximal screws—using the distal screws as a fulcrum to lift the vertebra via rod leverage.20 This method requires rod curvature to be precise, as poor curvature harms reduction/spinal stress.21 Furthermore, leverage depends on the surgeon’s experience; excess force may deform rods, fracture screws, or injure nerves.22

In this study, the modified assisted reduction and internal fixation system is mainly composed of an improved pedicle screw and rod fixation device and a ball-slide-type interbody distractor, with each component working in synergy to achieve dual enhancements in reduction accuracy and fixation stability. First, at the screw design level, by selectively increasing the thread depth and thickness, the contact area between the screw and bone tissue is expanded, enhancing the bite effect of the thread on the bone tissue, thereby significantly improving the pullout resistance of the screw. Second, in terms of the reduction mechanism, we employ direct traction with a traction screw, simplifying intraoperative procedures and reducing operational difficulty while ensuring effective reduction. Third, the central part of the traction screw is designed with a hemispherical contact surface, enabling it to apply precise and uniform axial compression to the vertebra during the pressurization and locking process, thereby further enhancing the accuracy of reduction and the stability of fixation. Fourth, using our designed ball-slide-type interbody distractor for distraction and assisted reduction, the forces are distributed in different directions, avoiding the localized stress overload caused by the concentrated force on traditional traction screws, thereby reducing complications such as screw loosening and fracture.

Clinical Significance

In this study, although no statistically significant differences were observed in the VAS and ODI scores between the observation group and the control group, Cohen’s d effect size analysis indicated small effect sizes for both groups in these measures, suggesting that the observation group had a clinically noticeable slight advantage in pain relief and functional improvement compared with the control group. Notably, the control group included 3 patients with severe pain, whereas no such cases occurred in the observation group. This study speculates that this difference may be related to the inherent limitations of traditional reduction and internal fixation systems in terms of reduction accuracy and uniform stress distribution, where certain patients experienced poor vertebral reduction and mechanical stimulation from the fixation to surrounding soft tissues, resulting in persistent or aggravated chronic postoperative pain. The modified assisted reduction and internal fixation system, by optimizing the screw thread structure and reduction locking mechanism, reduced the incidence of such adverse events, indirectly confirming that the modified system has greater clinical benefits.

Radiological Effects

In this study, we compared the radiological examination results between the observation group and the control group and found the following important results. First, compared with the control group, the postoperative reduction degree of spondylolisthesis in the observation group was higher. In the observation group of this study, the mid-grade (II) spondylolisthesis achieved almost complete reduction. The reduction of the high-grade (III) spondylolisthesis was satisfactory. The reason lies in the fact that when using the traditional pedicle screw system to treat the mid- to high-grade spondylolisthesis, the reduction process typically occurs on the rough “bone-bone” interface. In contrast, utilizing the modified interbody distractor provides a smoother interface that undoubtedly offers greater mechanical advantages, resulting in better reduction outcomes. Second, the control of distraction distance poses challenges when implementing intervertebral distraction using traditional pedicle screw systems, which may lead to excessive extension of the intervertebral space.23 In this study, the observation group utilized the modified assisted reduction and internal fixation system combined with a unilateral track distractor, applying appropriate distraction to achieve the desired intervertebral height.24 The results indicate that at the 1-year follow-up, the postoperative intervertebral space height and fusion rate in the observation group were both higher than those in the control group. We believe that this is closely related to the intervertebral height during the procedure, which may be a potential influencing factor.25

Complications

The traditional pedicle screw system relies solely on the traction and fixation force of the screws to achieve the reduction of the slipped vertebral body. However, this reduction process only restores the anatomical position of the vertebral body but cannot fill the space left by disc resection in the intervertebral space in a timely manner. As a result, the intervertebral space is in a “hollow” state without effective structural support after the reduction procedure.26 More force must be exerted to lift the vertebral body and achieve the desired effect.27 When the distraction force is excessive or imbalanced, the force may be focused on 1 point of the pedicle screw system.28 With the increase in time, metal fatigue occurs, and the loosening or breakage of the titanium alloy fixation system was observed in 2 patients in the control group.

In long-term studies, fractures due to fatigue of the fixation system have been reported. However, the modified interbody distractor solves these problems. It provides a reliable support structure when the pedicle screw system plays a reducing role in surgery.29 Meanwhile, the modified interbody distractor undertakes part of the stress that belongs to the fixation system.30 All the parts of the fixation system are in perfect balance. This improved fixation and assisted reduction technology is effective in preventing the fracture of the internal implant system.

With the application of the modified interbody distractor, the whole reducing process depends on the slide of the distractor. As the power of the superiorly directed force decreases, the modified fixation system could prevent the injury on the bone-screw surface and avoid the loosening of the pedicle screw system. This is particularly important in patients with osteoporosis. Therefore, no fractures of the fixation system were found in the observation group.

Limitations

First, this study was limited to patients with IS. The applicability of this modified system to degenerative lumbar spondylolisthesis and other spinal conditions (such as spinal fractures or degenerative scoliosis) remains unclear, and its clinical scope needs to be further verified through studies involving a broader range of subjects. Second, the sample size of this study was relatively small and derived from a single center, leading to insufficient statistical power, which resulted in key efficacy indicators such as the VAS and ODI scores not showing statistically significant differences. Future research should conduct multicenter, large-sample, prospective randomized controlled trials to more objectively and reliably validate the clinical advantages of the modified system. Last, this study primarily focused on clinical efficacy observations and did not delve into the biomechanical mechanisms related to the modified system. The potential mechanism by which it promotes bone fusion and alleviates postoperative pain still needs to be elucidated through in vitro biomechanical testing, animal experiments, and other basic research to provide a more solid theoretical foundation for systematic clinical application.

Conclusion

Compared with the traditional reduction and internal fixation system, the application of the modified assisted reduction and internal fixation system can achieve better clinical outcomes in alleviating postoperative chronic pain and improving long-term prognosis in patients with IS.

Footnotes

  • Funding This study was jointly supported by the Xingtai Municipal Bureau of Science and Technology (Grant: 2023ZZ051) and the Postdoctoral Fund of Hebei Province (Grant: B2020005003).

  • Declaration of Conflicting Interests The authors report no conflicts of interest in this work.

  • Ethical Considerations The study was approved by the Ethics Committee of Harrison International Peace Hospital and was conducted in strict compliance with the ethical guidelines set forth in the Declaration of Helsinki. All patients provided written informed consent before enrollment.

References

  1. 1.
    ↵
    Mohile NV , Kuczmarski AS , Lee D , Warburton C , Rakoczy K , Butler AJ . Spondylolysis and isthmic spondylolisthesis: a guide to diagnosis and management. J Am Board Fam Med. 2022;35(6):1204–1216. 10.3122/jabfm.2022.220130R1
  2. 2.
    ↵
    Choi GS , Boudier-Revéret M , Chang MC . The short-term outcome of transforaminal epidural steroid injection in patients with radicular pain due to foraminal stenosis from lumbar isthmic spondylolisthesis. J Pain Res. 2024;17:519–524. 10.2147/JPR.S441358
  3. 3.
    ↵
    Bhalla A , Bono CM . Isthmic lumbar spondylolisthesis. Neurosurg Clin N Am. 2019;30(3):283–290. 10.1016/j.nec.2019.02.001
  4. 4.
    ↵
    Gonzalez-Ramos K , Hanif Z , Shahid M , Guzman N , Hurlock NP . Prevalence of failed back surgery syndrome across hospital corporation of america healthcare in the united states, their correlation with mood disorders and other lifestyle-related comorbidities. Am J Lifestyle Med. 2024;18(4):527–535. 10.1177/15598276231196499
  5. 5.
    ↵
    Alshammari HS , Alshammari AS , Alshammari SA , Ahamed SS . Prevalence of chronic pain after spinal surgery: a systematic review and meta-analysis. Cureus. 2023;15(7):e41841. 10.7759/cureus.41841
  6. 6.
    ↵
    Kwon WK , Theologis AA , Kim JH , Moon HJ . Lumbar fusion surgery in the era of an aging society: analysis of a nationwide population cohort with minimum 8-year follow-up. Spine J. 2024;24(8):1378–1387. 10.1016/j.spinee.2024.03.003
  7. 7.
    ↵
    Hajilo P , Imani B , Zandi S , Mehrafshan A , Khazaei S . Risk factors analysis and risk prediction model for failed back surgery syndrome: a prospective cohort study. Heliyon. 2025;11(1):e40607. 10.1016/j.heliyon.2024.e40607
  8. 8.
    ↵
    Wu Y , Shen R , Li S , Luo T , Rong L , Zhang L . Fusion surgery for lumbar spondylolisthesis: a systematic review with network meta-analysis of randomized controlled trials. World Neurosurg. 2024;185:327–337. 10.1016/j.wneu.2024.02.051
  9. 9.
    ↵
    He R , Tang GL , Chen K , Luo ZL , Shang X . Fusion in situ versus reduction for spondylolisthesis treatment: grading the evidence through a meta-analysis. Biosci Rep. 2020;40(6):BSR20192888. 10.1042/BSR20192888
  10. 10.
    ↵
    Hitchon PW , Mahoney JM , Harris JA , et al . Biomechanical evaluation of traditional posterior versus anterior spondylolisthesis reduction in a cadaveric grade I slip model. J Neurosurg Spine. 2019;31(2):246–254. 10.3171/2019.2.SPINE18726
  11. 11.
    ↵
    Clancy C , Quinn A , Wilson F . The aetiologies of failed back surgery syndrome: a systematic review. J Back Musculoskelet Rehabil. 2017;30(3):395–402. 10.3233/BMR-150318
  12. 12.
    ↵
    Betz JW , Lightstone DF , Oakley PA , Haas JW , Moustafa IM , Harrison DE . Reliability of the biomechanical assessment of the sagittal lumbar spine and pelvis on radiographs used in clinical practice: a systematic review of the literature. J Clin Med. 2024;13(16):4650. 10.3390/jcm13164650
  13. 13.
    ↵
    Bouchard A , Mun J , Vazquez F , et al . Radiographic robustness of lumbar interbody fusion techniques. Global Spine J. 2025;15(1):59–65. 10.1177/21925682241226659
  14. 14.
    ↵
    Bourassa-Moreau É , Mac-Thiong J-M , Labelle H . Redefining the technique for the radiologic measurement of slip in spondylolisthesis. Spine (Phila Pa 1986). 2010;35(14):1401–1405. 10.1097/BRS.0b013e3181c3e740
  15. 15.
    ↵
    Issa TZ , Lee Y , Berthiaume E , et al . Utility of seated lateral radiographs in the diagnosis and classification of lumbar degenerative spondylolisthesis. Asian Spine J. 2023;17(4):721–728. 10.31616/asj.2022.0443
  16. 16.
    ↵
    Weir S , Samnaliev M , Kuo T-C , et al . The incidence and healthcare costs of persistent postoperative pain following lumbar spine surgery in the UK: a cohort study using the clinical practice research datalink (CPRD) and hospital episode statistics (HES). BMJ Open. 2017;7(9):e017585. 10.1136/bmjopen-2017-017585
  17. 17.
    ↵
    Miękisiak G . Failed back surgery syndrome: no longer a surgeon’s defeat—a narrative review. Medicina (Kaunas). 2023;59(7):1255. 10.3390/medicina59071255
  18. 18.
    ↵
    Liu ZD , Li XF , Qian L , Wu LM , Lao LF , Wang HT . Lever reduction using polyaxial screw and rod fixation system for the treatment of degenerative lumbar spondylolisthesis with spinal stenosis: technique and clinical outcome. J Orthop Surg Res. 2015;10:29. 10.1186/s13018-015-0168-x
  19. 19.
    ↵
    Wu Z , Zhan C , Cui G , et al . Stress distribution on the screws in posterior lumbar fusion of isthmic spondylolisthesis with 2- or 3-vertebra fixation techniques: a biomechanical cadaveric study. J Surg Res. 2012;176(1):95–101. 10.1016/j.jss.2011.05.004
  20. 20.
    ↵
    Omidi-Kashani F , Hootkani A , Jarahi L , Rezvan M , Moayedpour A . Radiologic and clinical outcomes of surgery in high grade spondylolisthesis treated with temporary distraction rod. Clin Orthop Surg. 2015;7(1):85–90. 10.4055/cios.2015.7.1.85
  21. 21.
    ↵
    Moufid AY , Cloche T , Ghailane S , Ounajim A , Vendeuvre T , Gille O . Mismatch between rod bending and actual post-operative lordosis in lumbar arthrodesis with poly axial screws. Orthop Traumatol Surg Res. 2019;105(6):1143–1148. 10.1016/j.otsr.2019.03.003
  22. 22.
    ↵
    Yang J , Peng Z , Kong Q , et al . Stretch on the L5 nerve root in high-grade spondylolisthesis reduction. J Neurosurg Spine. 2022;37(2):232–240. 10.3171/2021.12.SPINE211237
  23. 23.
    ↵
    Daher M , Nassar JE , Ikwuazom CP , et al . Cortical trajectory versus traditional pedicle screw trajectory in open transforaminal lumbar interbody fusion: meta-analysis of complications and clinical outcomes. World Neurosurg. 2024;189:212–219. 10.1016/j.wneu.2024.06.062
  24. 24.
    ↵
    Serratrice N , Faddoul J , Tarabay B , et al . Radiological factors affecting functional outcome after the implantation of BDYN™ dynamic stabilization system for low-grade lumbar degenerative spondylolisthesis. Neurochirurgie. 2023;69(4):101456. 10.1016/j.neuchi.2023.101456
  25. 25.
    ↵
    Kaliya-Perumal A-K , Soh TLT , Tan M , Oh JY-L . Factors influencing early disc height loss following lateral lumbar interbody fusion. Asian Spine J. 2020;14(5):601–607. 10.31616/asj.2019.0332
  26. 26.
    ↵
    Ould-Slimane M , Prost S , d’Astorg H , et al . Fusion and clinical outcomes of lumbar interbody fusion for low-grade isthmic spondylolisthesis. Orthop Traumatol Surg Res. 2023;109(2):103508. 10.1016/j.otsr.2022.103508
  27. 27.
    ↵
    Wu L , Jiang X , Guan T , He Z , Li J . Biomechanical properties analysis of posterior lumbar interbody fusion with transpedicular oblique screw fixation. Heliyon. 2024;10(19):e38929. 10.1016/j.heliyon.2024.e38929
  28. 28.
    ↵
    Xu M , Yang J , Lieberman I , Haddas R . Stress distribution in vertebral bone and pedicle screw and screw-bone load transfers among various fixation methods for lumbar spine surgical alignment: a finite element study. Med Eng Phys. 2019;63:26–32. 10.1016/j.medengphy.2018.10.003
  29. 29.
    ↵
    Zhong W , Liang X , Luo X , Huang T , Quan Z . Complications rate of and risk factors for the unplanned reoperation of degenerative lumbar spondylolisthesis in elderly patients: a retrospective single-centre cohort study of 33 patients. BMC Geriatr. 2020;20(1):301. 10.1186/s12877-020-01717-2
  30. 30.
    ↵
    Li P , Zhao Z , Jia N , Wang L , Sun Z , Jin X . A ball-slide-type interbody distractor is effective in posterior reduction and internal fixation for patients with mid- to high-grade isthmic spondylolisthesis enrolled in a randomized clinical trial. Medicine (Baltimore). 2019;98(47):e17947. 10.1097/MD.0000000000017947
View Abstract
Loading
Loading

ISASS27 Annual Conference at Loews Miami Beach Hotel, April 23-25, 2027