Learns more about the ioverame dials branch treatments

Outcomes and Complications Associated With 191 Carbon Fiber Pedicle Screws in Spinal Oncology Patients

  • International Journal of Spine Surgery
  • August 2026,
  • 20
  • (4)
  • 664-670;
  • DOI: https://doi.org/10.14444/8905

Abstract

Background Carbon-fiber-reinforced polyetheretherketone (CFR-PEEK) instrumentation is used in spinal tumor surgery owing to its reduced artifact on postoperative imaging.

Objective To evaluate the outcomes and complications associated with the use of CFR-PEEK instrumentation.

Methods This case series reviews 35 patients who underwent surgery using CFR-PEEK instrumentation between December 2020 and April 2025 at 2 academic institutions. Variables collected included demographics, cancer type, tumor location, tumor histology, surgical technique (open vs minimally invasive), and mortality at the latest follow-up. Categorical variables were described with frequencies, while continuous variables were described with means and SDs.

Results Thirty-five patients underwent 36 CFR-PEEK instrumentation procedures, utilizing a total of 191 screws. Patients had a mean age of 60.97 years (range: 15–83 years), and 23 patients (65.7%) were men. Thirty-one patients (88.6%) had metastatic spine tumors, with most tumors affecting the thoracic spine (51.4%). The most common histologies were multiple myeloma (n = 5) and lung cancer (n = 5). Twenty-two (66.6%) patients had a pathological fracture, while 16 (45.71%) had spinal cord compression on initial presentation. The mean estimated blood loss was 547.1 mL (range: 70–2000 mL). There were 1 intraoperative and 6 postoperative complications. One surgical revision was necessary due to a symptomatic screw. Median follow-up time was 5 months. The mortality rate at the latest follow-up was 40% (n = 14).

Conclusion Our experience with CFR-PEEK implants demonstrates outcomes comparable to titanium implants. While CFR-PEEK facilitates the detection of local recurrences more quickly, long-term, large-scale studies are necessary to assess its cost-effectiveness.

Clinical Relevance This case series describes the use of carbon fiber instrumentation in patients with spinal tumors and encourages future studies to compare it with other instrumentation methods.

Level of Evidence 4.

Introduction

The Centers for Disease Control and Prevention reported 1.6 million cases of new cancer diagnoses and 609,347 deaths due to cancer in 2020.1 It was the second leading cause of death following heart disease in the United States.1 Primary bone cancer accounts for approximately 1% of cancer cases. However, bone, especially the spine, is a common site for cancer metastasis.2–4 A recent systematic review by Van den Brand et al, evaluating metrics across 56 oncological studies, estimates that 15.7% of cancer patients are diagnosed with spinal metastases over the course of the disease, and even more go undiagnosed.5 The high rate of spinal metastases is primarily attributed to the valveless structure of the vertebral venous plexus, allowing hematogenous bidirectional retrograde blood flow to the spine, facilitating cancer spread to the spinal vertebrae.6 Among spinal metastases, the most common primary tumors include lung, breast, and prostate.3,5

While bony metastases may present with pain and weakening of the surrounding bone, spinal metastases specifically pose a unique risk for pathological vertebral fractures and epidural compression.7 Vertebral compression fractures can adversely affect axial skeletal stability and compromise sagittal balance, as the spine becomes kyphotic proximal to the fracture. Additionally, epidural compression caused by spinal metastases can lead to rapid neuromotor deterioration, requiring urgent surgical intervention to prevent further damage to the spinal cord and maximize functional outcomes in those affected. Van den Brand et al estimated the incidence of metastatic vertebral compression fractures and metastatic cord compression to be 12.6% and 9.6%, respectively, in patients with known cancer.5

Currently, cancer patients requiring spinal stabilization are treated with titanium or cobalt-chrome implants. Unfortunately, these implants can cause imaging artifacts, delaying the detection of new metastases or new growth within known metastases. Additionally, these implants can impact postoperative radiotherapy in 2 ways: first, metal implants raise the difficulty of localization of areas with known tumor burden, and second, metal implants absorb radiation and lessen radiotherapy’s effectiveness.8 To overcome these limitations, novel carbon fiber implants are radiolucent, reducing artifact production and radiation absorption. However, more research is needed to better assess the efficacy and outcomes of carbon fiber implants. Our study presents a case series of 35 spine oncology patients treated with carbon-fiber-reinforced polyetheretherketone (CFR-PEEK) spinal instrumentation. By depicting outcomes and long-term results, we aim to expand the current understanding of this alternative instrumentation.

Methods

Spine oncology patients managed by the senior author with CFR-PEEK between December 2020 and April 2025 were evaluated. Inclusion criteria were patients with primary and/or metastatic bone tumor treated with CFR-PEEK implants. Exclusion criteria included patients who underwent surgery after April 2025, as this did not allow for a minimum postoperative period of 6 months. Variables collected included demographics (age, sex, and race/ethnicity), cancer type, tumor location, tumor histology, surgical technique (open vs minimally invasive), estimated blood loss, and mortality at latest follow-up. Categorical variables were described with frequencies, while continuous variables were summarized using descriptive statistics. Motor function was assessed preoperatively and postoperatively at various time points using the American Spinal Injury Association (ASIA) motor score, which ranges from 0 to 100. A paired t test was used to compare the mean ASIA motor score pre- and postoperatively for cases with at least 6 months of motor data, with an alpha value of 0.05 denoting significance. The Kaplan-Meier analysis was used to evaluate survival time from index surgery to the latest follow-up.

Results

Demographics

During the study period, 35 patients met the inclusion criteria. Our cohort comprised 23 men (65.7%) and 12 women (34.3%), with a mean age at surgery of 60.97 years (range: 15–83 years). Most patients were white (n = 21, 60%), followed by black (n = 11, 31.4%) and Hispanic/other (n = 3, 8.6%; Table 1).

View this table:
Table 1

Demographics (N = 35).

Tumor Characteristics

Thirty-one patients (88.6%) had metastatic spine tumors, with the most common cancers being lung cancer and multiple myeloma at an incidence of 14.3% each (5/35). The most affected spine segment was the thoracic spine (18/35, 51.4%). Of 35 patients, 33 had verifiable radiological pathologies and radiation status. Twenty-two patients (66.6%) presented with pathological fractures, while 16 (48.5%) presented with cord compression. Four patients (12.1%) received preoperative radiation, and 19 (57.6%) received postoperative radiation (Table 2).

View this table:
Table 2

Tumor characteristics of spinal oncology patients (N = 35).

Surgical Data

Of 36 procedures, 14 (42.4%) were minimally invasive. A total of 191 screws were placed: carbon fiber only, 80.6% (29/36), and hybrid (carbon fiber and titanium), 19.4% (7/36). Mean estimated blood loss was 547.1 mL (range: 70–2000 mL). Intraoperative complication rate was 2.8% (1/35), while the postoperative complication rate was 16.7% (6/35; Table 3).

View this table:
Table 3

Surgical data of patients with bone tumor treated with CFR-PEEK implants.

Outcomes

Figure 1 depicts the mean change in motor scores from preoperative to 1, 3, and 6 months postoperatively for 16 cases. A paired t test was performed to compare mean preoperative and postoperative ASIA motor scores at each postoperative time point; the mean ASIA motor score was significantly higher at 1 month postoperatively (P = 0.04). The remaining postoperative time points were not statistically different from one another (P > 0.05). The mortality rate for the cohort was 40% (14/35) by final follow-up, with 11 patients passing away within 1 year of their surgeries (Table 3). Kaplan-Meier analysis demonstrated a mean survival time of 20.4 months (95% CI 14.7–26.1) and a median survival time of 27 months (95% CI 0–60.1). The Kaplan-Meier curve (Figure 2) showed an early decline, indicating that several patients died soon after surgery.

Figure 1

Mean change in ASIA motor score postoperatively for 16 cases that had available motor score data for at least 6 mo postoperatively. Error bars represent SD. Patients with less than 6 mo worth of data were excluded. *Denotes significant difference in mean motor scores between 2 time points (P = 0.04). ASIA, American Spinal Injury Association.

Figure 2

Kaplan-Meier curve for 35 cases. Early decline indicates that several patients died early in the follow-up period, while the flattening beyond 10 mo indicates that most patients remained stable thereafter. Many patients were lost to follow-up, resulting in heavy censoring throughout.

Discussion

Carbon Fiber Instrumentation Use

Currently, titanium or cobalt-chrome instrumentation is commonly used for patients with metastatic spine disease with symptomatic epidural compression or spinal instability. However, titanium implants can produce imaging artifacts and diminish the effectiveness of postoperative radiotherapy.9 Interest in CFR-PEEK instrumentation for oncological spinal surgery has increased in recent years due to its radiolucent nature, which can help identify recurrence earlier and assist with radiation therapy planning.

CFR-PEEK spinal implants, first developed in 1978 and approved by the US Food and Drug Administration for human use in the 1990s, can circumvent some limitations of titanium instrumentation.10 CFR-PEEK instrumentation has many desirable properties, including high wear and radiation resistance and a relatively low Young’s modulus, which reduces stress shielding compared with titanium.11 However, its radiolucency may be the most critical attribute in this patient population, as it enables high-quality postoperative imaging with minimal artifact (Figure 3).

Figure 3

A 68-year-old woman with a 20-y history of primary T3–T4 low-grade chondrosarcoma status after debulking, T1–T8 posterior spinal fusion, and proton beam radiation. The patient presented with thoracic pain without neurological deficits and concern for tumor recurrence. (A) Sagittal and (B) axial T2 magnetic resonance imaging without contrast of the thoracic spine demonstrate right-sided tumor recurrence at T3 (circle) with extension into the spinal canal and cord compression. Axial computed tomography (CT) without contrast at T1 (C) demonstrates bilateral titanium pedicle screws (solid arrows) from previous T1 to T8 fusion. (D) Right-sided destructive changes at T3 vertebral body. The patient underwent revision T3 partial corpectomy, T2–T4 laminectomy with removal of extradural tumor, and removal of T1–T7 instrumentation, with carbon fiber rods and screws replacement. Axial CT without contrast 3 mo after the operation demonstrates (E) bilateral carbon fiber screws at T1 (hollow arrows). (F) T3 status after partial corpectomy. Note the difference in imaging artifacts produced by titanium (C) compared with carbon fiber screws (E) (arrows).

The benefits of carbon implant systems must be weighed against the cost of these implants, which is often significantly higher than their titanium counterparts,12 as well as any unforeseen changes in the peri- and postoperative course due to the differences in material properties and/or implantation method. Unfortunately, much remains unknown about the use of CFR-PEEK in clinical practice and the outcomes of patients receiving CFR-PEEK instrumentation. Our case series details our experience with CFR-PEEK instrumentation, discussing complications and mortality in cancer patients who receive CFR-PEEK implants for both primary and metastatic spinal cancer.

The existing literature is similarly limited by variation in follow-up rates and median follow-up times. Patients with metastatic spine cancer have a median survival rate of 10 months, which may significantly contribute to varying follow-up intervals.13 Most tumors recur after the first 3 years; therefore, future studies should emphasize a follow-up period of at least 5 years to capture recurrence and remission rates.14

Recurrence

One of the main advantages of CFR-PEEK is its radiolucency, which reportedly enables more accurate imaging and precise photon therapy.11 A recent study by Ward et al compared local tumor recurrence rates and time to detection in patients with titanium alloy implants vs those with CFR-PEEK instrumentation.15 There was no significant difference in recurrence incidence between the groups. However, local recurrence in patients with CFR-PEEK implantations was detected on average 95 days earlier than in the titanium group.15 Early detection of recurrence enables timely intervention and treatment, preventing further spread. We recorded a recurrence rate of 9.1%, with a mean time to recurrence of 7.9 months, which is lower than rates reported in a similar study that used both titanium and CFR-PEEK instrumentation, which reported a recurrence rate of 57.9% at 6 months.16 However, in our series, given that our cohort was primarily palliative (89% metastatic and 40% mortality at ~5 months), faster recurrence detection is not necessarily applicable. Instead, adequacy of decompression immediately postoperatively is much more relevant to palliative patients.

Complications

Literature shows that the durability of CFR-PEEK is comparable to that of titanium alloy.17 In this study, 2.1% of cases exhibited breakage of CFR-PEEK pedicle screws.16 We report a similar figure of 2.8%, noting 1 instance, out of 36 procedures, in which a carbon fiber screw broke intraoperatively. A similar study with a median follow-up of 8 months using titanium alloy screws notes a failure rate of 13.8%, with 3.4% of failures requiring revision surgery. The risk factor for instrumentation failure was myelomatous spine lesions.17 The aforementioned carbon fiber screw break in our case series occurred in a patient with metastatic lung cancer who underwent hybrid instrumentation.

A study by Ringel et al stated that CFR-PEEK has no biomechanical inferiority to titanium screws and offers lower material fatigue and virtually unbreakable strength, which may be superior for long-term hardware stability. Pedicle screws break when the forces exerted on them by the surrounding anatomy exceed their ultimate strength along a given axis. Longer screws, on average, exhibit a greater bending strength.16 Therefore, the length should be considered when assessing the failure rate of CFR-PEEK screws. We were able to record the results of screws across a variety of levels with several different lengths, lending some external validity to the results of our work. However, our limited median follow-up time of 5 months precludes definitive conclusions on carbon fiber screw durability. Future prospective studies can better evaluate long-term screw integrity.

A postoperative complication rate of 16.7% (6/36) was recorded in our case series, similar to median spinal complication rates of 7% to 20%.18 This rate is lower when compared with complications and reoperation rates in spinal metastasis surgery with titanium alloy, which has a complication rate of 34%.2 Three patients had surgical site infections that required incision and drainage, and 1 patient had an epidural hematoma that required evacuation. Our relatively low rate of surgical site infections may be attributable, in part, to wound-complication prevention strategies implemented by the senior author, including intrawound vancomycin powder, which has been shown to substantially reduce the incidence of wound infections.19–21 The remaining 2 complications consisted of 1 patient with carbon fiber-only implants who underwent revision surgery within 2 weeks of surgery to reposition a right S1 symptomatic percutaneous screw. One patient developed a CSF leak that required reoperation and placement of a lumbar drain.

Physician Preference

Physician preference, health system contracting, and expenses are some of the determinants of whether CFR-PEEK will be commonly used for oncological spinal surgeries. Surgeons in each study concluded that CFR-PEEK instrumentation is comparable to or more advantageous than titanium alloy.8,22–28 Joerger et al and Boriani et al recommend their use in cancer patients due to improved cancer treatment, leading to more aggressive radiotherapy and therefore less surgery.27,28 Joerger et al included computed tomography and magnetic resonance imaging of CFR-PEEK instrumentation, demonstrating reduced perturbation effects and a more optimal postoperative radiotherapy regimen of 40/50 Gy á 2/2,5 G.27

Limitations

This case series was limited by a small sample size, which limits our findings. Additionally, follow-up durations varied, including imaging intervals, creating uncertainty in the assessment of the collected data. Overall, postoperative symptom improvement in patients with CFR-PEEK could not be thoroughly assessed because different scales were used, including the visual analog scale for pain and the ASIA Impairment Scale for neurological assessment. Despite the use of different assessment tools, each assessment reported improvements across both measures postoperatively, and our findings similarly showed improvements in ASIA motor scores. However, additional outcome measures, including patient-reported outcomes, would provide a more robust assessment; future prospective studies would benefit greatly from their incorporation. Last, during the literature search for this case series, we identified 8 articles reporting a total of 673 patients.8,15,23–28 However, nearly half (48%; n = 321) of these cases were from a single retrospective study by Joerger et al.27 This gap in existing studies underscores the importance of collecting more patient data on CFR-PEEK implants. Ultimately, more consistent research is needed to compare long-term outcomes with CFR-PEEK. Currently, CFR-PEEK seems to be an appropriate alternative to titanium alloy screws, and with more research, it may become the preferred treatment modality for spinal tumors.

Conclusion

CFR-PEEK is comparable to titanium in stability and efficacy. CFR-PEEK instrumentation produces fewer artifacts on imaging. However, more conclusive evidence is necessary to determine whether it significantly improves remission intervals and/or oncological outcomes in these patients. Carbon fiber instrumentation has been associated with a reduction in time to detect recurrence by more than 3 months; however, the level of evidence to support this association is low, deriving from a case-matched series. Furthermore, despite their increased costs, no significant difference has been found in the overall recurrence rate, patient survival, or surgical complications with carbon fiber implants. Based on the available data, it is unclear whether a lower recurrence detection time confers any significant benefit to the affected patient population. However, more research directly comparing the benefits of titanium and CFR-PEEK implants is necessary before a definitive answer regarding their superiority to standard titanium implants can be reached.

Footnotes

  • Funding The authors received no financial support for the research, authorship, and/or publication of this article.

  • Declaration of Conflicting Interests Addisu Mesfin reports grants from Globus, AO Spine, OREF, and Nuvasive; consulting fees from Globus and GS Medical; payment or honoraria from Stryker, Medtronic, and DePuy; support for attending meetings/travel from Medtronic; leadership or fiduciary roles in the CSRS, LSRS, SRS, NASS, AAPS, AOA, and JRGOS; and stock/stock options in Axiomed and Efficient Surgical apps. The remaining co-authors have no conflict of interest to declare.

  • Ethical Approval and Informed Consent This study received IRB approval under Study Protocol STUDY00008070 and STUDY0000497. Both institutions’ ethics committees approved the study, which was conducted in accordance with the Declaration of Helsinki.

References

  1. 1.
    ↵
    An update on cancer deaths in the united states. February. 2022;28. https://stacks.cdc.gov.
  2. 2.
    ↵
    Key Statistics About Bone Cancer. American Cancer Society. https://www.cancer.org/cancer/types/bone-cancer/about/key-statistics.html.
  3. 3.
    ↵
    Jayarangaiah A , Kemp AK , Theetha Kariyanna P . Bone metastasis. StatPearls. StatPearls Publishing; 2025.
  4. 4.
    ↵
    Versteeg AL , Charest-Morin R , De La Garza Ramos R , et al . Association between nutritional status and survival in patients requiring treatment for spinal metastases. Neurosurgery. 2025. 10.1227/neu.0000000000003834
  5. 5.
    ↵
    Van den Brande R , Cornips EM , Peeters M , Ost P , Billiet C , Van de Kelft E . Epidemiology of spinal metastases, metastatic epidural spinal cord compression and pathologic vertebral compression fractures in patients with solid tumors: a systematic review. J Bone Oncol. 2022;35:100446. 10.1016/j.jbo.2022.100446
  6. 6.
    ↵
    Carpenter K , Decater T , Iwanaga J , et al . Revisiting the vertebral venous plexus-a comprehensive review of the literature. World Neurosurg. 2021;145:381–395. 10.1016/j.wneu.2020.10.004
  7. 7.
    ↵
    Barbanti Brodano G , Griffoni C , Salamanna F , et al . Evaluation of adverse events and the impact on health-related outcomes in patients undergoing surgery for metastatic spine tumors: analysis of the Metastatic Tumor Research and Outcomes Network (MTRON) registry dataset. Global Spine J. 2026;16(1):410–433. 10.1177/21925682251347247
  8. 8.
    ↵
    Ringel F , Ryang Y-M , Kirschke JS , et al . Radiolucent carbon fiber-reinforced pedicle screws for treatment of spinal tumors: advantages for radiation planning and follow-up imaging. World Neurosurg. 2017;105:294–301. 10.1016/j.wneu.2017.04.091
  9. 9.
    ↵
    Zavras AG , Schoenfeld AJ , Patt JC , et al . Attitudes and trends in the use of radiolucent spinal implants: a survey of the north american spine society section of spinal oncology. North American Spine Society Journal (NASSJ). 2022;10:100105. 10.1016/j.xnsj.2022.100105
  10. 10.
    ↵
    Kumar N , Ramakrishnan SA , Lopez KG , et al . Can polyether ether ketone dethrone titanium as the choice implant material for metastatic spine tumor surgery? World Neurosurg. 2021;148:94–109. 10.1016/j.wneu.2021.01.059
  11. 11.
    ↵
    Fleege C , Makowski M , Rauschmann M , et al . Carbon fiber-reinforced pedicle screws reduce artifacts in magnetic resonance imaging of patients with lumbar spondylodesis. Sci Rep. 2020;10(1):16094. 10.1038/s41598-020-73386-5
  12. 12.
    ↵
    Pahlavan S , Berven S , Bederman SS . Variation in costs of spinal implants in United States academic medical centers. SPINE (Phila Pa 1976). 2016;41(6):515–521. 10.1097/BRS.0000000000001271
  13. 13.
  14. 14.
  15. 15.
    ↵
    Ward J , Damante M , Wilson S , et al . Impact of instrumentation material on local recurrence: a case-matched series using carbon fiber-PEEK vs. titanium. J Neurooncol. 2025;171(1):155–162. 10.1007/s11060-024-04842-9
  16. 16.
    ↵
    Laufer I , Iorgulescu JB , Chapman T , et al . Local disease control for spinal metastases following “separation surgery” and adjuvant hypofractionated or high-dose single-fraction stereotactic radiosurgery: outcome analysis in 186 patients. J Neurosurg Spine. 2013;18(3):207–214. 10.3171/2012.11.SPINE12111
  17. 17.
    ↵
    Longo M , De la Garza Ramos R , Gelfand Y , Echt M , Kinon MD , Yassari R . Incidence and predictors of hardware failure after instrumentation for spine metastasis: a single-institutional series. World Neurosurg. 2019;125:e1170–e1175:S1878-8750(19)30391-2. 10.1016/j.wneu.2019.01.272
  18. 18.
    ↵
    Barbanti-Brodano G , Griffoni C , Halme J , et al . Spinal surgery complications: an unsolved problem-is the world health organization safety surgical checklist an useful tool to reduce them? Eur Spine J. 2020;29(5):927–936. 10.1007/s00586-019-06203-x
  19. 19.
    ↵
    Leary OP , Setty A , Gong JH , et al . Prevention and management of posterior wound complications following oncologic spine surgery: narrative review of available evidence and proposed clinical decision-making algorithm. Global Spine J. 2025;15(1_suppl). 10.1177/21925682241237486
  20. 20.
    ↵
    Mesfin A , Botros M , Benn L , Kulp A . Risk factors for surgical site infections and the effects of betadine irrigation and intrawound vancomycin powder on infection rates in spine tumor surgery. Cureus. 2024;16(7):e64591. 10.7759/cureus.64591
  21. 21.
    ↵
    Mesfin A , Baldwin A , Bernstein DN , et al . Reducing surgical site infections in spine tumor surgery: a comparison of three methods. Spine (Phila Pa 1976). 2019;44(24):E1428–E1435. 10.1097/BRS.0000000000003177
  22. 22.
    ↵
    Schwendner M , Ille S , Kirschke JS , et al . Clinical evaluation of vertebral body replacement of carbon fiber-reinforced polyetheretherketone in patients with tumor manifestation of the thoracic and lumbar spine. Acta Neurochir (Wien). 2023;165(4):897–904. 10.1007/s00701-023-05502-z
  23. 23.
    ↵
    Wagner A , Haag E , Joerger A-K , et al . Cement-augmented carbon fiber-reinforced pedicle screw instrumentation for spinal metastases: safety and efficacy. World Neurosurg. 2021;154:e536–e546. 10.1016/j.wneu.2021.07.092
  24. 24.
    ↵
    Neal MT , Richards AE , Curley KL , et al . Carbon fiber-reinforced PEEK instrumentation in the spinal oncology population: a retrospective series demonstrating technique, feasibility, and clinical outcomes. Neurosurg Focus. 2021;50(5):E13. 10.3171/2021.2.FOCUS20995
  25. 25.
    ↵
    Cofano F , Di Perna G , Monticelli M , et al . Carbon fiber reinforced vs titanium implants for fixation in spinal metastases: a comparative clinical study about safety and effectiveness of the new “carbon-strategy”. J Clin Neurosci. 2020;75:106–111. 10.1016/j.jocn.2020.03.013
  26. 26.
    ↵
    Alvarez-Breckenridge C , de Almeida R , Haider A , et al . Carbon fiber-reinforced polyetheretherketone spinal implants for treatment of spinal tumors: perceived advantages and limitations. Neurospine. 2023;20(1):317–326. 10.14245/ns.2244920.460
  27. 27.
    ↵
    Joerger A-K , Seitz S , Lange N , et al . CFR-PEEK pedicle screw instrumentation for spinal neoplasms: a single center experience on safety and efficacy. Cancers (Basel). 2022;14(21):5275. 10.3390/cancers14215275
  28. 28.
    ↵
    Boriani S , Tedesco G , Ming L , et al . Carbon-fiber-reinforced PEEK fixation system in the treatment of spine tumors: a preliminary report. Eur Spine J. 2018;27(4):874–881. 10.1007/s00586-017-5258-5
View Abstract
Loading
Loading