Learns more about the ioverame dials branch treatments

2026 ISASS Spine Bone Graft Policy Update: Class III Technologies and Contemporary Evidence Maturation

  • International Journal of Spine Surgery
  • October 2026,
  • 8971;
  • DOI: https://doi.org/10.14444/8971

Abstract

Background The 2018 International Society for the Advancement of Spine Surgery (ISASS) bone graft policy established the society’s comprehensive framework for bone graft substitutes in spinal surgery. Additionally, a subsequent independent 2019 analysis by Marx and Lorio examined the regulatory and evidentiary distinctions applicable to class III spinal grafts. Since those publications, substantive regulatory, evidentiary, and technological developments have emerged that warrant a focused ISASS policy update.

Methods A focused regulatory and clinical evidence landscape review was conducted to answer the question, “What has materially changed since the previous ISASS review?” The review aimed to identify substantive regulatory, evidentiary, and technological developments warranting policy reassessment, not to constitute a comprehensive systematic re-review.

Results Two principal areas of class III/premarket approval maturation were identified: continued regulatory and evidentiary maturation of rhBMP-2/INFUSE and maturation and expansion of P-15 peptide technology through distinct i-FACTOR cervical and PearlMatrix lumbar premarket approval pathways. AUGMENT and MagnetOs serve as complementary regulatory and evidentiary boundary examples rather than additional class III spinal maturation pathways.

Conclusions Regulatory pathway, biological mechanism, Food and Drug Administration indication, clinical evidence, coding, coverage, and reimbursement are related but distinct dimensions of spinal bone graft assessment and should not substitute for one another. Graft selection ultimately remains within the treating surgeon’s purview (Figure).

Introduction and Rationale

Two elements remain fundamental to successful spinal fusion: (1) mechanical stability sufficient to limit motion across the intended fusion environment and (2) a biological strategy that supports de novo bone formation across prepared fusion surfaces.1,2 Proper graft selection may influence the durability of an instrumented fusion, the risk of pseudarthrosis, and associated clinical outcomes.1,3

Autograft has historically served as the reference standard because it can provide osteogenic cells, osteoinductive signals, and an osteoconductive scaffold.2,3 Local autograft may be obtained during the operative exposure, whereas iliac crest or other separate-site harvest can provide additional graft volume at the cost of added operative work and potential donor-site morbidity.4,5 These limitations contributed to the development of allografts, demineralized matrices, synthetic scaffolds, cellular products, recombinant proteins, peptide-enhanced grafts, and other biological strategies.3,5,6

These products enter clinical practice through different regulatory pathways, including human cell and tissue regulation, 510(k) clearance, and premarket approval (PMA).6–9 Those pathways are not interchangeable, and regulatory classification alone does not establish biological mechanism, comparative effectiveness, clinical interchangeability, or payer coverage.6–11

The 2018 ISASS Recommendations and Coverage Criteria for Bone Graft Substitutes Used in Spinal Surgery provided a comprehensive assessment of the principal graft categories relevant to spinal fusion at that time.6 Subsequent analysis of class III spinal grafts further emphasized the regulatory and evidentiary distinctions applicable to technologies subject to PMA.10

The present update (Figure 1) does not aim to reconstruct those reviews. Rather, it asks a more focused question: “What has materially changed since the previous ISASS review?”

Figure

ISASS class III spine bone graft policy update.

A focused regulatory and evidence landscape review was therefore directed toward developments involving new US Food and Drug Administration (FDA) approvals or material indication expansions; expansion of class III/PMA spinal platforms; maturation of prospective, randomized, comparative, or long-term clinical evidence; development of new biological mechanisms or material architectures; changes affecting the distinction between FDA-approved and physician-directed applications; and developments with potential implications for coverage, coding, reimbursement, or clinical adoption.

The focused review identified 2 principal areas of class III/PMA maturation: continued regulatory and evidentiary maturation of rhBMP-2 technology and maturation and expansion of P-15 peptide technology through distinct cervical and lumbar PMA pathways.

Two additional technologies provide useful regulatory and evidentiary boundary conditions. The rhPDGF-BB/β-TCP orthobiologic AUGMENT demonstrates that class III/PMA status does not itself establish an FDA spinal indication. Conversely, surface-engineered biphasic calcium-phosphate technology, commercially available as MagnetOs, provides a contemporary non-PMA comparator illustrating that prospective spinal fusion evidence may mature after 510(k) clearance and should be assessed independently of regulatory classification. Neither example is treated as an additional class III spinal maturation pathway.

The present update is, therefore, intentionally focused rather than exhaustive. Categories for which no material regulatory, biological, or evidentiary change was identified remain grounded in the prior ISASS recommendations.6 This resulting policy update is intended as a supplement to a living ISASS bonegraft policy: stable in its governing principles, but responsive to material developments in science, regulation, evidence, surgical application, and coverage.

This policy uses specific product and brand names where necessary to provide regulatory and clinical granularity because FDA clearance or approval, classification, indications, and supporting evidence are product and application specific. Inclusion or discussion of a particular product does not constitute endorsement by ISASS, nor should omission be interpreted as a determination regarding the safety, effectiveness, or clinical utility of another product.

Regulatory and Evidence Framework

Regulatory Pathway

The regulatory pathway through which a bone graft technology reaches clinical practice provides important information, but should not be confused with a complete assessment of clinical evidence.8–16 A device cleared through 510(k) is evaluated principally on substantial equivalence to an appropriate predicate. The type and extent of supporting data may vary by device and the regulatory questions presented.8

PMA represents a different and generally more demanding premarket pathway under which the FDA determines whether valid scientific evidence provides reasonable assurance of safety and effectiveness for the specified product and indication.9 These pathways should not be treated as equivalent. Conversely, a 510(k)-cleared technology may subsequently develop substantial randomized, comparative, or long-term clinical evidence. Such evidence may strengthen assessment of that technology but does not convert 510(k) clearance into PMA approval.

Unless otherwise specified, regulatory classifications used in this policy refer to the US FDA framework. Similarly named device classes in other jurisdictions should not be assumed to represent equivalent regulatory pathways or evidentiary requirements.

Product- and Indication-Specific Regulation

FDA approval or clearance is product, indication, and conditions-of-use specific.9,13–15 INFUSE, i-FACTOR, and PearlMatrix have FDA-approved spinal applications through the PMA pathway.17–19 AUGMENT is also a PMA orthobiologic but does not have an FDA-approved spinal indication.20 MagnetOs is not PMA approved but has 510(k) clearance encompassing specified spinal applications.21,22 Neither regulatory status nor evidence should be extrapolated automatically among products merely because they share a material category, biological concept, or commercial function.

PMA Supplements and Evolving Labeling

PMA products may undergo supplemental FDA review after initial approval.12 Some supplements materially alter clinical indications, approaches, constructs, or conditions of use; others address manufacturing, testing, administrative, or other changes without substantively expanding the clinical indication. For policy purposes, these actions should be clearly distinguished. A clinically substantive indication expansion may materially change a technology’s appropriate characterization in payer policy. A manufacturing or administrative supplement ordinarily should not be represented as equivalent clinical maturation.

FDA Labeling and Physician-Directed Use

FDA labeling defines the applications for which a manufacturer has obtained regulatory authorization and may promote the product.13 Federal law does not, however, generally permit FDA to regulate the practice of medicine with respect to legally marketed devices.14 Physician-directed use outside labeling should therefore be described accurately. Such use is not FDA approved for that particular application, but off-label status alone does not establish that a treatment is experimental or investigational.14,15 Assessment should instead consider the supporting evidence, biological rationale, medical necessity, patient circumstances, procedural requirements, risks, reasonable alternatives, and applicable professional standards.

Regulatory Status and Coverage

FDA status and payer coverage answer different questions.11,16 FDA approval does not independently guarantee coverage, and physician-directed use outside labeling does not independently establish noncoverage. Nevertheless, payer policy should accurately reflect current FDA status. When the FDA materially expands an approved indication, policies based upon superseded labeling should be updated accordingly.

Clinical Evidence

One should interpret evidence in relation to the technology and application actually studied. Trial design, comparator, anatomical location, surgical approach, construct, patient population, outcome definition, duration of follow-up, and safety findings all influence the extent to which evidence can reasonably be generalized. Clinical evidence that develops following regulatory authorization should be evaluated on its own methodological merits and should not be inferred solely from the regulatory pathway through which a technology entered the market.

Governing Principles

  1. Regulatory pathway, biological mechanism, FDA indication, clinical evidence, and coverage are related but distinct dimensions of assessment.

  2. PMA represents a different and generally more demanding premarket threshold than 510(k) clearance; subsequent evidence maturity should also be assessed independently.

  3. FDA approval or clearance is product, indication, and conditions-of-use specific and should neither be diminished nor extrapolated beyond those boundaries.

  4. Clinical application should remain cognizant of patient biology, fusion environment, current FDA labeling, and applicable instructions for use (IFU), supporting evidence, procedural constraints, risks, alternatives, and relevant cost considerations.

  5. Within these parameters, the selection of the appropriate graft strategy remains within the purview of the treating surgeon.

rhBMP-2/Infuse Bone Graft

Historical Position

Recombinant human bone morphogenetic protein-2 represents the most established class III/PMA biologically active bone graft technology in spinal fusion.6,10,23–25 INFUSE combines rhBMP-2 with an absorbable collagen sponge carrier and promotes osteogenic differentiation through bone morphogenetic protein signaling.23–25 The FDA originally approved INFUSE under PMA P000058 in 2002 for specified single-level anterior lumbar interbody fusion applications.17 Subsequent supplements expanded approved lumbar applications, implants, and approaches.17 Clinical adoption also extended into posterior lumbar applications, including transforaminal lumbar interbody fusion (TLIF), and those applications historically were characterized as outside FDA labeling.6,10 That regulatory status materially changed in 2026.

2026 FDA Approval for TLIF

On 13 February 2026, the FDA approved PMA Supplement P000058/S096, expanding INFUSE labeling to include 1- or 2-adjacent-level TLIF from L2 to S1 in appropriately selected patients with symptomatic degenerative disc disease after at least 6 months of nonoperative treatment.26,27 The approved application requires an FDA-cleared interbody fusion device and metallic screw-and-rod supplemental fixation according to the applicable labeling.26,27 Therefore, S096 is not simply additional clinical evidence. The FDA specifically reviewed and approved a posterior lumbar application historically regarded as off-label.

Pivotal Evidence

S096 was supported by a prospective, randomized, controlled, single-blind, multicenter investigation involving 480 patients at 53 sites.27 Patients were randomized to 2.1 mg rhBMP-2 per level, 4.2 mg rhBMP-2 per level, or control; local autograft was used according to the study protocol, with optional mineralized cancellous allograft in the interbody space. The investigational comparison therefore should not be interpreted as rhBMP-2 alone vs autograft alone.27 A Bayesian adaptive design permitted enrollment to stop after prespecified evidence of efficacy was achieved.27

At 24 months, 1-level radiographic fusion was 87.5% with 2.1 mg rhBMP-2, 90.0% with 4.2 mg, and 61.8% with local autograft. For 2-level procedures, corresponding fusion rates were 78.9%, 86.7%, and 43.8%.27 Overall success at 24 months was 68.6%, 70.1%, and 53.6% for the respective 1-level groups and 57.9%, 60.0%, and 20.0% for the respective 2-level groups.27

Overall success incorporated Oswestry Disability Index (ODI) success, radiographic fusion, neurological success, absence of serious adverse events related to the graft or interbody device, and absence of secondary surgery classified as failure. The FDA concluded that the investigational groups met the applicable noninferiority criteria for overall success and demonstrated superior radiographic fusion, with posterior probabilities greater than 0.999. Time to fusion was also shorter with INFUSE.27

Safety Considerations

For 1-level procedures, cumulative adverse-event rates were generally similar among groups. Serious adverse events at 24 months were higher in the 4.2 mg group than in the control group in the aggregate analysis, although individual serious-adverse-event categories did not differ significantly. Construct-related adverse events and serious adverse events did not differ significantly among treatment groups.27

Radiographic heterotopic ossification occurred more frequently in the INFUSE groups, although no statistically significant difference in radiculopathy was demonstrated. One patient in the 4.2 mg group experienced radiculopathy classified as a serious adverse event requiring secondary surgery.27 For 2-level procedures, serious adverse events were numerically more frequent in the INFUSE groups but did not reach statistical significance.27 These findings reinforce the importance of dose, anatomical location, containment, construct, and proximity to neural structures when applying a biologically active graft.24–27

Historical cervical safety experience remains relevant. The FDA formally issued this action as a Public Health Notification on 1 July 2008, concerning life-threatening complications associated with recombinant human bone morphogenetic protein in cervical spine fusion.28

ISASS Policy Position

The 13 February 2026 FDA approval of PMA Supplement P000058/S096 materially changes the regulatory status of rhBMP-2 in posterior lumbar interbody fusion. Payer policies that categorically characterize TLIF use of INFUSE bone graft as off-label should be revised to reflect current FDA labeling. For patients and constructs satisfying the approved indication, 1- or 2-adjacent-level TLIF from L2 to S1 represents an FDA-approved application. Uses outside the conditions specified in the labeling remain physician-directed applications and should be evaluated based on available clinical evidence, medical necessity, patient-specific circumstances, and reasonable alternatives, rather than being considered experimental solely because they fall outside FDA labeling.14,26,27

INFUSE’s contemporary significance is the maturation of an established class III platform through substantive indication expansion supported by dedicated, randomized evidence.

P-15 Peptide Technology: i-Factor and PearlMatrix

Platform Overview

P-15 represents the second major class III/PMA biologically active platform considered in this update.10,18,19 P-15 is a synthetic 15-amino-acid peptide designed to mimic a cell-binding domain of type I collagen and provide a biomimetic surface supporting cellular attachment and subsequent osteogenic activity.29–31 Unlike rhBMP-2, P-15 is not a recombinant morphogen or growth factor. The contemporary P-15 story consists of 2 related but distinct PMA pathways: i-FACTOR in cervical fusion and PearlMatrix in lumbar fusion.18,19 Their shared peptide technology does not make the products, indications, or supporting evidence interchangeable.

i-FACTOR: Maturation of the Cervical Pathway

The FDA approved i-FACTOR under PMA P140019 on 3 November 2015, for specified single-level anterior cervical fusion applications from C3 to C4 through C6 to C7 in skeletally mature patients following discectomy for qualifying radiculopathy or myelopathy after failure of conservative treatment.18 The original approval specified use within an allograft bone ring with supplemental anterior plate fixation.18

The pivotal investigation enrolled 319 treated patients and compared i-FACTOR with local autograft within an allograft ring. The study demonstrated noninferiority across the prespecified primary outcome framework, establishing the regulatory basis for cervical approval.32 Long-term follow-up subsequently demonstrated maintenance of clinical and radiographic outcomes through 6 years, supporting characterization of i-FACTOR as a mature cervical evidence pathway.33

On 13 September 2024, the FDA approved PMA Supplement P140019/S011, expanding the permitted construct to include use of i-FACTOR in conjunction with a polyetheretherketone (PEEK), titanium-alloy, or PEEK/titanium cervical fusion interbody device cleared by the FDA for cervical use, together with supplemental anterior plate fixation.34

This should not be generalized as authorization for use in any cervical interbody device. Applicable device and fixation requirements remain conditions of use. The contemporary significance of i-FACTOR is, therefore, maturation of an established cervical PMA through longer-term clinical experience and expanded construct labeling.

PearlMatrix: Extension of P-15 Into Lumbar Fusion

PearlMatrix represents a separate regulatory development. The FDA approved PearlMatrix under PMA P240001 on 18 June 2025, for specified single-level lumbar interbody fusion from L2 to S1 in skeletally mature patients with degenerative disc disease, with up to grade I spondylolisthesis, after at least 6 months of nonoperative treatment.19

The original approval specified use with a PEEK TLIF fusion device and supplemental internal fixation.19 PearlMatrix, therefore, did not obtain a lumbar indication through extrapolation from i-FACTOR. It entered lumbar fusion through its own PMA supported by lumbar-specific evidence.19

Expanded Lumbar Labeling

On 11 December 2025, the FDA approved the separate PMA Supplement P240001/S001, expanding PearlMatrix implantation to anterior lumbar interbody fusion, TLIF, posterior lumbar interbody fusion, oblique lateral interbody fusion/anterior-to-psoas, and lateral lumbar interbody fusion approaches and permitting specified titanium-alloy and PEEK/titanium interbody fusion cages in addition to the original PEEK constructs.35 This supplemental action is distinct from the original P240001 PMA and is, therefore, treated as a separate regulatory reference in this policy.

ASPIRE Pivotal Evidence

The PearlMatrix PMA was supported by the prospective, randomized ASPIRE investigation conducted at 33 US sites.36,37 The FDA primary effectiveness analysis included 293 subjects in the modified intention-to-treat population: PearlMatrix = 143 and control = 150.36 The control strategy used local autograft with allograft chips as needed in single-level TLIF.36,37

Composite clinical success at 24 months required no index-level secondary surgical intervention, computed tomography (CT)-confirmed fusion, at least a 15-point ODI improvement, no new or worsening persistent neurological deficit, and no device-related serious adverse event.36 Composite clinical success was 55.4% (67/121) with PearlMatrix compared with 36.4% (47/129) in the control group.36 The prespecified noninferiority criterion was satisfied, and the multiplicity-controlled analysis also met the prespecified criterion for superiority.36

Interpretation requires examination of the components. The FDA’s assessment indicated that the between-group difference was driven principally by lower fusion performance in the control group, while ODI, neurological outcomes, and device-related serious adverse events were more similar. PearlMatrix also had a higher index-level secondary-surgery rate in the FDA analysis. Accordingly, the evidence supports PearlMatrix without requiring the stronger claim that every component independently demonstrated superiority.36 The separately reported time-to-fusion analysis provides additional characterization of the lumbar P-15 evidence base.38

Recall Context

A subsequent limited class II recall involved 237 units from a single PearlMatrix 1.0 cc lot because of an incorrect expiration date. The FDA identified the cause as labeling change control.39 The FDA’s recall record identifies a labeling-related action involving a limited product lot.39

ISASS Policy Position

P-15 peptide technology has materially evolved since the previous ISASS review. i-FACTOR represents a mature class III/PMA cervical platform with longer-term clinical experience and expanded construct labeling, while PearlMatrix represents a separately approved class III/PMA lumbar application supported by dedicated randomized evidence and subsequent expansion of approved surgical approaches and interbody constructs. Coverage policies should reflect the current product-specific FDA labeling and supporting evidence. Evidence or approval associated with 1 P-15 product should not automatically be extrapolated to another product or anatomical application solely because the technologies share the P-15 platform.

A Contemporary Non-PMA Comparator: Surface-Engineered Synthetic Bone Graft Technology

Why the Comparator Is Included

This update focuses on the maturation of class III/PMA spinal bone graft technologies. MagnetOs is included solely as an illustrative contemporary comparator outside that pathway. It is a surface-engineered synthetic biphasic calcium-phosphate graft regulated through the class II/510(k) pathway and is not a class III/PMA technology.21,22

Its inclusion addresses a limited evidentiary question: whether prospective spinal fusion evidence may develop after a technology enters clinical practice through 510(k) clearance. The example is used to separate subsequent evidence appraisal from regulatory classification; it is not presented as a third policy pathway or as a basis for a coverage recommendation.21,22,40–44

Regulatory Status

MagnetOs has received FDA 510(k) clearance as a resorbable calcium salt bone-void-filler technology encompassing specified spinal applications.21,22 The applicable labeling permits defined posterolateral spinal use and establishes specific requirements for intervertebral applications, including use with an FDA-cleared interbody device indicated for use with a bone void filler and preparation according to the applicable IFU.21,22 Therefore, the appropriate terminology is FDA cleared, not FDA approved.

Material Architecture and Biological Rationale

MagnetOs is a synthetic biphasic calcium phosphate incorporating a surface architecture characterized by submicron-scale features.21,40–43 Conventional calcium phosphate grafts have historically been described primarily as osteoconductive scaffolds. Contemporary investigation of surface-engineered calcium phosphates suggests that microarchitecture and surface topography may additionally influence cellular behavior within the healing environment, including macrophage phenotype and subsequent osteogenic signaling.40–43

This interaction among material architecture, immune-cell behavior, angiogenesis, and bone formation falls under the broader concept of osteoimmunomodulation.42,43 Terminology requires precision. MagnetOs should not be characterized casually as “osteoinductive” merely because biological responses beyond passive osteoconduction have been reported. A more appropriate description in the present policy is a surface engineered, osteopromotive or osteoimmunomodulatory synthetic bone graft technology.40–43 The biological significance of surface architecture should be supported by technology-specific mechanistic and clinical evidence rather than generalized across synthetic grafts as a class.

Prospective Randomized Human Evidence and Limitations

The principal contemporary clinical development is the prospective, randomized, multicenter investigation reported by Stempels et al in 2024.44 The trial enrolled 100 adults undergoing instrumented posterolateral spinal fusion across 1 to 6 levels at 5 centers. Each patient received 10 cc of MagnetOs on 1 side of the posterolateral fusion and 10 cc of autograft on the contralateral side. The primary efficacy outcome was posterolateral fusion assessed by the thin-slice CT scan at 1 year. In the observed analysis, fusion was present on 79% of MagnetOs-treated sides and 47% of autograft-treated sides; the paired primary analysis supported noninferiority and superiority for the radiographic fusion-performance endpoint.44

Interpretation should remain appropriately limited. Although patient-reported outcomes measures (PROM) were collected, the intrapatient design did not permit treatment-specific comparison of patient-reported clinical efficacy. The primary comparison was, therefore, predominantly radiographic rather than a PROM-based clinical-efficacy endpoint. The authors also noted moderate interobserver reliability for CT fusion assessment and cautioned that slowly resorbing ceramic remnants may resemble bone, creating uncertainty in distinguishing residual graft material from fusion on 1-year CT images.44

Scope of the Comparator

Other contemporary synthetic bone graft technologies, including magnesium-enriched and other ion-substituted hydroxyapatites, have also developed emerging spinal clinical evidence. Magnesium-enriched hydroxyapatite, including the CE-marked SINTlife platform evaluated in a prospective spinal fusion pilot study, is particularly instructive from an international regulatory perspective. SINTlife was classified as a class III medical device under the European regulatory framework applicable to that study; this designation should not be conflated with the FDA class III classification or PMA in the United States. Although the emerging spinal experience with magnesium-enriched hydroxyapatite warrants recognition, the available clinical evidence did not meet the focused evidentiary threshold used in this update to select an illustrative non-PMA comparator.45,46

Accordingly, MagnetOs is not included among the class III/PMA technologies addressed by the formal recommendations of this policy. It is presented as a contemporary non-PMA comparator illustrating that regulatory classification and the subsequent maturation of clinical evidence represent distinct dimensions of spinal bone graft assessment. Its inclusion should not be interpreted as extending the conclusions or recommendations of this policy to class II synthetic bone graft substitutes as a category.

Augment: A Class III/PMA Regulatory Boundary Condition

AUGMENT bone graft incorporates recombinant human platelet-derived growth factor-BB with a beta-tricalcium phosphate matrix and received FDA PMA for specified ankle and hindfoot arthrodesis applications as an alternative to autograft.20 It does not have an FDA-approved spinal fusion indication.20 Therefore, AUGMENT demonstrates that class III/PMA status alone does not establish an FDA-approved spinal application. PMA approval remains product and indication specific, and evidence from ankle and hindfoot arthrodesis should not be assumed to establish effectiveness in spinal fusion.

AUGMENT and MagnetOs consequently provide complementary boundary conditions. AUGMENT asks whether PMA status establishes a spinal indication; it does not. MagnetOs asks whether entry through 510(k) precludes the later development of meaningful prospective spinal evidence; it does not. These examples clarify the framework without constituting additional class III spinal maturation pathways.20–22,44

ISASS recommends that PMA status not be extrapolated beyond the product and indication the FDA actually approved. Class III technologies should not be considered interchangeable, and PMA approval for a nonspinal application should not be represented as FDA approval for spinal fusion.

Comparative Regulatory and Evidence Framework

The comparative framework distinguishes the 2 principal class III/PMA maturation pathways from the complementary boundary examples used to clarify the relationship among regulatory pathway, spinal indication, and subsequent evidence development. (Table)

View this table:
Table

Comparative regulatory and evidence framework.

  1. Identify the regulatory pathway;

  2. Determine the specific current FDA-approved or cleared indication and conditions of use;

  3. Characterize the biological mechanism and material architecture;

  4. Evaluate product-and application-specific evidence; and

  5. Integrate these findings with patient biology, procedural requirements, risks, reasonable alternatives, and relevant cost considerations.

Regulatory pathway, biological mechanism, FDA indication, and clinical evidence are complementary rather than interchangeable. Assessment should, therefore, remain technology, application, and patient specific.

Biological Augmentation and Procedural Recognition

A spinal fusion strategy may include not only commercially prepared graft materials but autologous biological resources such as bone marrow aspirate (BMA).6 BMA is distinct from the manufactured recombinant and peptide technologies emphasized in this update. Bone marrow contains heterogeneous cellular and signaling elements potentially relevant to bone repair, but its composition varies according to patient biology, aspiration site and technique, aspirated volume, peripheral-blood dilution, and subsequent processing.6 BMA, therefore, should not be regarded as a standardized cellular product, nor should the addition of BMA be assumed to make otherwise distinct scaffolds or graft materials biologically equivalent.

Procedural recognition has previously evolved alongside spinal bone graft practice. Effective 1 January 2018, Current Procedural Terminology (CPT) 20939 provides a spine-specific category I add-on code for bone marrow aspiration performed for bone grafting in spine surgery through a separate skin or fascial incision.6,47 Because CPT 20939 was implemented contemporaneously with the 2018 ISASS bone graft policy, its existence does not represent a new coding development warranting the present focused update.6,47

CPT 20939 describes the physician service of obtaining BMA for spinal bone grafting under specified procedural conditions; the code itself does not establish the regulatory classification, clinical effectiveness, or coverage status of a graft technology with which the aspirate may subsequently be used.

ISASS Coverage Recommendations and Medical-Necessity Principles

FDA regulatory status, clinical evidence, payer coverage, coding, and reimbursement represent related but distinct dimensions of spinal bone graft assessment. FDA approval or clearance establishes the applicable regulatory status and authorized labeling but does not, by itself, determine payer coverage or reimbursement.16 Coverage determinations should consider the applicable regulatory status, quality and maturity of clinical evidence, patient-specific clinical circumstances, and the requirements of the individual payer.

ISASS coverage recommendations do not identify a universally preferred graft or permit payer substitution of 1 technology for another. Coverage should provide reasonable evidence-based boundaries within which the treating surgeon can select a graft strategy appropriate to the individual patient and fusion environment.

The discussion of a contemporary non-PMA comparator in this update is intended to illustrate the distinction between regulatory classification and subsequent evidence development and does not establish a separate coverage recommendation for that technology or for class II synthetic bone graft substitutes as a category.

Regulatory Status and Current FDA Labeling

Coverage policy should reflect current product- and indication-specific FDA regulatory status together with applicable reasonable-and-necessary criteria. When the FDA approves a clinically substantive indication expansion, payer policies should be reassessed accordingly. Conversely, approval should not be extrapolated beyond the product, indication, and conditions of use FDA reviewed.12,16–22,34,35

Physician-Directed Use Outside Labeling

Physician-directed use of an FDA-regulated technology outside its labeled indication should be distinguished from the manufacturer’s FDA-authorized labeling. Such use should be evaluated according to the individual clinical circumstances, available evidence, applicable law and professional standards, and payer coverage requirements; the existence of physician-directed use does not itself establish coverage.14–16

Evidence Should Be Technology and Application Specific

Regulatory classification, manufacturer, material category, or shared biological platform should not establish clinical interchangeability. Evidence should be assessed for the specific technology and proposed application, including anatomical location, approach, construct, patient population, fusion assessment, clinical outcomes, safety, and duration of follow-up. High-quality evidence developed after 510(k) clearance should be considered on its merits without mischaracterizing the regulatory pathway.21,22,40–44

Coverage Should Reflect Fusion Biology and Procedural Requirements

Coverage criteria should permit consideration of factors materially influencing graft selection, including available local autograft, bone quality, previous pseudarthrosis, revision status, number of levels, metabolic or systemic risk factors, surgical approach, fusion-bed characteristics, construct stability, and morbidity associated with separate-site graft harvest.3–6 Patient-specific factors may materially influence the biological environment for arthrodesis. Obesity, for example, has been associated with approximately 2-fold greater odds of nonunion following lumbar spinal fusion, underscoring the importance of considering host biology and the fusion environment when selecting a graft strategy.48 Such evidence identifies biological risk; it does not establish that a particular graft class or product necessarily overcomes that risk.

The surgeon should remain cognizant of current FDA labeling and applicable IFU, including requirements concerning preparation, dose or quantity, carrier, hydration, containment, anatomical location, interbody device, and supplemental fixation.

Risk Must Be Application Specific

Safety should be assessed according to technology and clinical application. Dose, anatomical location, containment, surgical approach, construct, proximity to neural structures, and patient characteristics may influence graft-related risk.24–28 Historical adverse events from 1 application should not automatically be generalized to every use, nor should a favorable experience in 1 setting establish safety in another.

Cost Should Inform, but Not Dictate, Graft Selection

Cost is a legitimate component of responsible health care decision-making, but acquisition price alone is an incomplete measure of value. Relevant considerations may include autograft harvest and donor-site morbidity, additional operative work, graft preparation, time to fusion, pseudarthrosis, secondary procedures, revision surgery, and complications, where supported by reliable evidence.3–6 Cost should inform graft selection but should not independently determine it.

Graft Selection Remains Within the Purview of the Surgeon

ISASS recognizes bone graft selection as an integral component of surgical planning that should remain within the treating surgeon’s purview. Selection should be informed by patient biology and the fusion environment; graft mechanism and material characteristics; current FDA approval or clearance and applicable IFU; quality and relevance of supporting evidence; procedural and construct requirements; patient-specific risks; reasonable alternatives; and relevant cost implications. Regulatory classification, acquisition cost, or payer preference alone should not substitute for individualized surgical judgment.

Consolidated ISASS Coverage Position

Coverage policy for spinal bone graft technologies should reflect the convergence of applicable regulatory status, indication-specific clinical evidence, patient-specific biological and surgical considerations, and reasonable-and-necessary criteria rather than any single dimension in isolation. FDA approval or clearance should not be conflated with a coverage determination, just as coding availability should not be interpreted as evidence of clinical effectiveness. Graft selection ultimately remains within the treating surgeon’s purview, exercised according to the individual patient’s clinical circumstances, the fusion environment, available evidence, applicable regulatory considerations, and payer requirements.16,48

Coding and Reimbursement

Coding, coverage, and reimbursement are important but distinct components of translating spinal bone graft science into clinical practice.6,16 Coding describes a service or resource within the applicable coding system. FDA approval or clearance establishes regulatory status for specified conditions of use. Coverage addresses medical necessity and benefit policy. Payment determines how a covered and reportable service or resource is reimbursed.

Established Spine Bone Graft Coding Framework

The category I CPT framework for bone grafting in spine surgery has not undergone material structural change since publication of the 2018 ISASS recommendations:6

  • 20930—morselized allograft or osteopromotive material

  • 20931—structural allograft

  • 20936—local autograft obtained through the same incision

  • 20937—morselized autograft obtained through a separate skin or fascial incision

  • 20938—structural autograft obtained through a separate skin or fascial incision

  • 20939—bone marrow aspiration for spine surgery for bone grafting through a separate skin or fascial incision

These spine-specific add-on codes describe graft-related services rather than individual commercial graft products and should be reported according to current CPT instructions and applicable payer requirements. Their availability does not establish coverage or separate payment for a particular commercial graft technology.

2026 SIJ Clarification

The 2026 CPT descriptors for sacroiliac joint arthrodesis codes 27278 and 27279 include obtaining bone graft when performed. Spine-specific bone graft codes 20930, 20931, and 20936 to 20939 are add-on codes subject to defined primary-procedure reporting requirements. Accordingly, separate reporting of these spine bone graft add-on codes with 27278 or 27279 is not supported by the applicable CPT add-on code reporting framework.49,50

ISASS Policy Principle

Coding recognition, FDA regulatory status, clinical evidence, coverage, and reimbursement remain distinct. The presence or absence of a product-specific CPT code should not determine whether an otherwise supported bone graft technology is medically necessary or investigational.

Reportability does not guarantee coverage or payment, and the absence of a product-specific CPT code does not establish that a graft technology is investigational. Commercial graft products generally should not be expected to correspond individually to unique physician-service CPT codes. Depending on payer and site of service, product costs may be incorporated into facility payment, packaged within another payment methodology, or addressed through payer-specific mechanisms.

Thus, physician coding, graft-product cost, facility payment, medical necessity, and coverage may represent different components of the same episode of care. A service may be correctly reportable, yet packaged or bundled for payment. Conversely, the existence of a code does not guarantee separate reimbursement. Denial of separate payment because a service is bundled should not automatically be interpreted as a determination that the underlying graft strategy is medically unnecessary.

Reimbursement policy should consider the economic context of the complete fusion strategy, not graft acquisition price alone. Where supported by evidence, relevant considerations may include graft cost, additional operative work, harvest morbidity, facility resources, complications, time to fusion, pseudarthrosis, and revision surgery. The objective is neither to automatically justify higher-cost technology nor to equate the lowest purchase price with the greatest clinical value.

ISASS recognizes coding, coverage, and reimbursement as essential but distinct components of translating spinal bone graft science into clinical practice. Coding recognition does not independently establish medical necessity, coverage, or payment, nor should absence of a product-specific CPT code be interpreted as evidence that an FDA-approved, FDA-cleared, or evidence-supported graft technology is investigational.

Contemporary translation therefore spans: Science → Evidence → Regulation → Surgical Application → Coding → Coverage → Reimbursement → Patient Access. Each component answers a different question.

Discussion

A Focused Update to a Living Policy

The principal finding of this focused update is not that the spinal bone graft landscape has been broadly transformed since the 2018 ISASS policy, but that 2 class III/PMA pathways have undergone sufficient regulatory and evidentiary maturation to warrant focused reassessment. The first is the continued maturation of the established rhBMP-2/INFUSE platform, culminating most recently in FDA approval of a specified TLIF indication. The second is the maturation of P-15 peptide technology through long-term i-FACTOR cervical evidence and the emergence and subsequent expansion of the distinct PearlMatrix lumbar PMA platform.26,27,32–38

AUGMENT provides a complementary regulatory boundary condition. Its PMA status demonstrates why device class and anatomical indication cannot be treated as interchangeable: AUGMENT is a PMA-approved orthobiologic, but its FDA-approved indication is ankle/hindfoot arthrodesis rather than spinal fusion.20 Conversely, MagnetOs illustrates that entry through a class II/510(k) pathway does not preclude the subsequent maturation of prospective spinal clinical evidence. Its inclusion therefore serves an evidentiary rather than class III regulatory function and should not be interpreted as extending the formal recommendations of this policy to class II synthetic bone graft substitutes as a category.21,22,44

Regulatory Precision Without Regulatory Reductionism

These examples reinforce a central principle of this update: regulatory pathway and clinical evidence answer different questions. PMA generally imposes a more demanding premarket regulatory framework than 510(k) clearance, but PMA status should not itself be interpreted as a surrogate for a particular level of clinical evidence. Conversely, 510(k) clearance should not be interpreted as evidence that meaningful prospective clinical data cannot subsequently develop.

Similarly, evidence generated outside or subsequent to an FDA-authorized indication should be evaluated on its methodological merits rather than treated as though it automatically changes the product’s labeling. Clinical evidence may mature without a corresponding indication expansion, just as an FDA regulatory action may address manufacturing or labeling without constituting new clinical evidence.

Bone graft policy, therefore, requires product- and indication-specific analysis. A biological mechanism shared across products does not create a shared FDA indication, and membership in the same regulatory class does not establish equivalent evidence, anatomical application, or coverage status.

Biology Remains the Clinical Center

Spinal fusion remains a biological process occurring within a mechanically prepared environment.1–3 The appropriate strategy depends upon interaction among the graft, host biology, prepared fusion surfaces, available cellular and vascular resources, and construct stability. Bone quality, previous pseudoarthrosis, revision status, number of levels, surgical approach, available autograft, systemic risk factors, and morbidity associated with graft harvest may alter the biological requirements of an individual fusion.3–6 The importance of individualized graft selection is further supported by evidence that host factors such as obesity materially affect lumbar fusion success.48

The clinically relevant question is, therefore, not simply, which graft is best? Rather, “What biological problem is the surgeon attempting to solve in this patient, in this fusion environment, with this construct?” The answer cannot be derived from regulatory class, mechanism, or product name alone.

Mechanistic plausibility remains important in graft selection, but biological mechanism should not substitute for clinical evidence. Osteoinductive signaling, cell-adhesive peptide biology, osteoconductive scaffolding, and surface-mediated cellular responses describe different biological strategies; none alone establishes comparative clinical effectiveness in a particular fusion environment.

IFU, Risk, Cost, and Surgeon Judgment

Graft selection must remain cognizant of current FDA labeling and applicable IFU. Preparation, dose, carrier, hydration, containment, anatomical location, approach, interbody-device requirements, supplemental fixation, and other procedural conditions may materially affect effectiveness and risk.

Cost is relevant, but acquisition price alone does not define value. Separate-site autograft may impose additional operative work and morbidity4,5; commercial technologies may impose greater acquisition expense; and failed fusion may generate substantial downstream consequences.

Within these regulatory and evidentiary boundaries, graft selection ultimately remains within the treating surgeon’s purview and should reflect the patient’s biology, anatomical and mechanical fusion environment, available evidence, applicable indication, and clinical judgment. Coverage policy should establish reasonable evidence-based boundaries around that judgment rather than replace it.

From Innovation to Patient Access

The appropriate sequence is: Science → Evidence → Regulation → Surgical Application → Coding → Coverage → Reimbursement → Patient Access.

Each step informs the next, but none is interchangeable with the others. Problems arise when a downstream element is allowed to substitute for an upstream determination—for example, when a CPT code is treated as evidence of clinical effectiveness, the FDA authorization is treated as an automatic coverage determination, or reimbursement policy is allowed to define biological appropriateness.16 Coding architecture should describe reportable services rather than drive biological selection. Likewise, reimbursement policy should follow—not redefine—the clinical and evidentiary rationale for graft use.

Maintaining a Living Policy

The focused nature of this update supports a living-policy model. Categories for which no material regulatory, evidentiary, or technological change has occurred need not be repeatedly re-reviewed solely to reproduce prior conclusions. Instead, focused reassessment should occur when evidence maturation, indication expansion, new regulatory pathways, or other substantive developments are sufficient to alter the policy landscape.

This policy update has limitations. The focused regulatory and clinical evidence landscape review was designed to identify material developments since the previous ISASS review rather than to constitute a comprehensive systematic re-review of all spinal bone graft technologies. Accordingly, categories without substantive regulatory, evidentiary, or technological change were not exhaustively reassessed. Regulatory status and labeling may also evolve after publication, and payer coverage policies remain heterogeneous and subject to change. The recommendations should therefore be interpreted within the defined scope and temporal context of this update.

Conclusion

Since the 2018 ISASS bone graft policy and subsequent 2019 independent class III analysis, 2 principal areas of class III/PMA maturation have emerged that warrant focused policy reassessment: continued regulatory and evidentiary maturation of the rhBMP-2/INFUSE platform and maturation and expansion of P-15 peptide technology through distinct i-FACTOR cervical and PearlMatrix lumbar PMA pathways. For rhBMP-2, the 2026 TLIF indication represents material regulatory maturation of an established PMA spinal platform. For P-15, long-term cervical evidence, expansion of the i-FACTOR cervical platform, and the emergence and subsequent expansion of the PearlMatrix lumbar PMA pathway collectively represent substantive evidentiary and regulatory maturation.

AUGMENT and MagnetOs provide complementary boundary conditions rather than additional class III spinal maturation pathways. AUGMENT demonstrates that PMA status alone does not establish a spinal indication, whereas MagnetOs demonstrates that 510(k) clearance does not preclude the subsequent maturation of meaningful prospective spinal clinical evidence. The inclusion of MagnetOs as a contemporary non-PMA comparator should not be interpreted as extending the formal class III/PMA recommendations of this policy to class II synthetic bone graft substitutes as a category.

Regulatory pathway, biological mechanism, FDA indication, clinical evidence, coding, coverage, and reimbursement are related but distinct dimensions of spinal bone graft assessment and should not substitute for one another. Graft selection ultimately remains within the treating surgeon’s purview. As regulatory indications, clinical evidence, technologies, and coverage environments continue to evolve, the ISASS bone graft framework should remain a living policy subject to focused reassessment when material developments warrant reconsideration.

Footnotes

  • Funding The authors received no financial support for the research, authorship, and/or publication of this article.

  • Declaration of Conflicting Interests Dr. Lavelle: Grants: Abryx; AO Foundation; Cerapedics; Empirical Spine; Medtronic; Spinal Kinetics, Inc.; 3 Spine; Synergy, Orthofix; Consulting fees: 4-Web, DePuy Spine Synthes; Payment or honoraria: 4-Web; Patents planned: DePuy Spine Synthes; Leadership: Innovasis, Vertiflex, TruSpine; Stock or stock options: 4-Web, Expanding Innovations. Dr. Fourman: Royalties or licenses: Astura; Consulting fees: Stryker, VB Spine; Payments or honoraria: Globus, 4_Web; Leadership: Associate Editor: Montefiore Journal of Musculoskeletal Medicine, Editorial Board Spine. Dr. Miloh: Nothing to disclose. Mr. Jain: Nothing to disclose. Dr. Vaccaro: Royalties or licenses: Atlas Spine, Curiteva, Elsevier, Globus, Jaypee, Spinal Elements, Spine Wave, Taylor Francis/Hodder and Stoughton, Thieme, Wheel House Medical; Consulting fees: Curiteva, Ferring Pharmaceutical, Globus, Medcura, Spinal Elements, Stryker Spine, Wheel House Medical, PE-Consulting, PBC Biomedical; Payment for expert testimony: AO Spine; Leadership: National Spine Health Foundation, Sentryx; Stock or stock options: Advanced Spinal Intellectual Properties, Atlas Spine, Avaz Surgical, Cytonics, Deep Health Dimension Orthotics, Electrocore, FlowPharma, Globus, Harvard Medtech, Innovative Surgical Design, Jushi, Orthobullets, Parvizi Surgical Innovation, Progressive Spinal Technologies, Rothman Institute and Related Properties, Sentryx, Stout Medical, ViewFi Health, Oxion Dental. Dr. Alves: Nothing to disclose. Dr. Mesfin: Nothing to disclose; Dr. Metkar: Nothing to disclose; Ms. Rybicki: Nothing to disclose. Dr. Lorio: Chair Emeritus: ISASS Task Force; ISASS Past President.

  • IRB Approval No IRB approval was required for this work.

  • Editor’s Note This article is a product of the Policy and Advocacy Committee of the International Society for the Advancement of Spine Surgery (ISASS) and is being published as an official communication of the ISASS Board of Directors. It did not undergo the standard review process of the journal but instead was reviewed, revised, and vetted under the authority of the society's Board. Dr. Lavelle is current ISASS RUC Advisor and Dr. Mesfin is current ISASS RUC Alternate Advisor. Drs. Vaccaro and Alves are current ISASS Co-Presidents—United States and International, respectively, and Dr. Lorio is Chair Emeritus ISASS Task Force and a Past President of ISASS.

References

  1. 1.
    ↵
    Sanghvi PA , Wiener JM , Meade SM , Boden LM , Shost MD , Steinmetz MP . Development of a unified and comprehensive definition of successful spinal fusion: a systematic review. J Neurosurg Spine. 2025;42(4):403–412. 10.3171/2024.9.SPINE2465
  2. 2.
    ↵
    Virk S , Qureshi S , Sandhu H . History of spinal fusion: where we came from and where we are going? HSS J. 2020;16(2):137–142. 10.1007/s11420-020-09747-7
  3. 3.
    ↵
    Radcliff K , Hwang R , Hilibrand A , et al . The effect of iliac crest autograft on the outcome of fusion in the setting of degenerative spondylolisthesis: a subgroup analysis of the Spine Patient Outcomes Research Trial (SPORT). J Bone Joint Surg Am. 2012; 94(18): 1685–1692. 10.2106/JBJS.K.00952
  4. 4.
    ↵
    Dimitriou R , Mataliotakis GI , Angoules AG , et al . Complications following autologous bone graft harvesting from the iliac crest and using the RIA: a systematic review. Injury. 2011;42(Suppl 2):S3–S15. 10.1016/j.injury.2011.06.015
  5. 5.
    ↵
    Plantz MA , Gerlach EB , Hsu WK. Synthetic bone graft materials in spine fusion: current evidence and future trends. Int J Spine Surg. 2021; 15(s1): 104–112. 10.14444/8058
  6. 6.
    ↵
    Abjornson C , Brecevich A , Callanan T , Dowe C , Cammisa FP , Lorio MP . ISASS recommendations and coverage criteria for bone graft substitutes used in spinal surgery. Int J Spine Surg. 2018;12(6):757–771. 10.14444/5095
  7. 7.
    ↵
    Human Cells, Tissues, and Cellular and Tissue-Based Products, 21 CFR §1271.10. 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-L/part-1271. 17 September 2026.
  8. 8.
  9. 9.
    ↵
    Premarket Approval of Medical Devices, 21 CFR §814. 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-H/part-814. 23 September 2026.
  10. 10.
    ↵
    Marx JG , Lorio MP , et al . Class III spine grafts. Barbeck M , Clinical Implementation of Bone Regeneration and Maintenance. London: IntechOpen; 2019. 10.5772/intechopen.87706
  11. 11.
    ↵
    Roginiel AC , Dhruva SS , Ross JS . Evidence supporting FDA approval and CMS national coverage determinations for novel medical products, 2005 through 2016: a cross-sectional study. Medicine (Baltimore). 2018;97(40):e12715. 10.1097/MD.0000000000012715
  12. 12.
  13. 13.
  14. 14.
  15. 15.
    ↵
    Position Statement 1177: Physician Directed Use of Medical Products. American Academy of Orthopaedic Surgeons. 2016. https://www.aaos.org/contentassets/1cd7f41417ec4dd4b5c4c48532183b96/1177-physician-directed-use-of-medical-products.pdf. 5 August 2026.
  16. 16.
    ↵
    Medicare Coverage of Items and Services: CMS Guide for Medical Technology Companies and Other Interested Parties. Updated 2026. Centers for Medicare & Medicaid Services. https://www.cms.gov/cms-guide-medical-technology-companies-and-other-interested-parties/coverage/medicare-coverage-items-and-services. 23 September 2026.
  17. 17.
    ↵
    INFUSE Bone Graft/LT-CAGE Lumbar Tapered Fusion Device. PMA P000058. U.S. Food and Drug Administration. July 2, 2002. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=p000058. 23 September 2026.
  18. 18.
    ↵
    I-FACTOR Peptide Enhanced Bone Graft, PMA P140019 and Applicable Supplements/Labeling. U.S. Food and Drug Administration. November 3, 2015. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P140019. 30 August 2026.
  19. 19.
    ↵
    PearlMatrix P-15 Peptide Enhanced Bone Graft. PMA P240001. U.S. Food and Drug Administration. June 18, 2025. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=P240001. 23 September 2026.
  20. 20.
    ↵
    AUGMENT Bone Graft. PMA P100006. U.S. Food and Drug Administration. September 1, 2015. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?id=p100006. 23 September 2026.
  21. 21.
    ↵
    510(k) Premarket Notification K213111: MagnetOs Granules. U.S. Food and Drug Administration. January 10, 2022. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?id=K213111. 23 September 2026.
  22. 22.
    ↵
    510(k) Premarket Notification K232347: MagnetOs Granules. U.S. Food and Drug Administration. Decision date January 19, 2024. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm?ID=K232347. 23 September 2026.
  23. 23.
    ↵
    Urist MR . Bone: formation by autoinduction. Science. 1965;150(3698):893–899. 10.1126/science.150.3698.893
  24. 24.
    ↵
    Mesfin A , Buchowski JM , Zebala LP , et al . High-dose rhBMP-2 for adults: major and minor complications: a study of 502 spine cases. J Bone Joint Surg Am. 2013;95(17):1546–1553. 10.2106/JBJS.L.01730
  25. 25.
    ↵
    Lord EL , Petersen K , Zabat M , Leucht P , Mesfin A , Fischer C . Biologics in spine fusion. Instr Course Lect. 2023;72:689–702.
  26. 26.
    ↵
    INFUSE Bone Graft. PMA Supplement P000058/S096. U.S. Food and Drug Administration. February 13, 2026. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?ID=P000058S096. 23 September 2026.
  27. 27.
    ↵
    Summary of Safety and Effectiveness Data: INFUSE Bone Graft, PMA P000058/S096. U.S. Food and Drug Administration. February 13, 2026. https://www.accessdata.fda.gov/cdrh_docs/pdf/P000058S096B.pdf?utm_medium=email&utm_source=transaction. 23 September 2026.
  28. 28.
    ↵
    Public Health Notification: Life-Threatening Complications Associated with Recombinant Human Bone Morphogenetic Protein in Cervical Spine Fusion. U.S. Food and Drug Administration. July 1, 2008.
  29. 29.
    ↵
    Qian JJ , Bhatnagar RS . Enhanced cell attachment to anorganic bone mineral in the presence of a synthetic peptide related to collagen. J Biomed Mater Res. 1996;31(4):545–554. 10.1002/(SICI)1097-4636(199608)31:43.0.CO;2-F
  30. 30.
    ↵
    Bhatnagar RS , Qian JJ , Gough CA . The role in cell binding of a B-bend within the triple helical region in collagen type I: structural and biological evidence for conformational tautomerism on fiber surface. J Biomol Struct Dyn. 1997;14(5):547–560. 10.1080/07391102.1997.10508155
  31. 31.
    ↵
    Yang XB , Rajendra S , Bhatnagar RS , Li S , Oreffo RO . Biomimetic scaffolds for human bone cell growth. Tissue Eng. 2004;10(7–8):1148–1158. 10.1089/ten.2004.10.1148
  32. 32.
    ↵
    Arnold PM , Sasso RC , Janssen ME , et al . Efficacy of i-factor bone graft versus autograft in anterior cervical discectomy and fusion: results of the prospective, randomized, single-blinded food and drug administration investigational device exemption study. Spine. 1976;41(13):1075–1083. 10.1097/BRS.0000000000001466
  33. 33.
    ↵
    Arnold PM , Vaccaro AR , Sasso RC , et al . Six-year follow-up of a randomized controlled trial of i-FACTOR peptide-enhanced bone graft versus local autograft in single-level anterior cervical discectomy and fusion. Neurosurgery. 2023;92(4):725–733. 10.1227/neu.0000000000002290
  34. 34.
    ↵
    I-FACTOR Peptide Enhanced Bone Graft. PMA Supplement P140019/S011. U.S. Food and Drug Administration. September 13, 2024.
  35. 35.
    ↵
    PearlMatrix P-15 Peptide Enhanced Bone Graft. PMA Supplement P240001/S001. U.S. Food and Drug Administration. December 11, 2025. https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpma/pma.cfm?ID=P240001S001. 23 September 2026.
  36. 36.
    ↵
    Summary of Safety and Effectiveness Data: PearlMatrix P-15 Peptide Enhanced Bone Graft. PMA P240001. U.S. Food and Drug Administration. June 18, 2025.
  37. 37.
    ↵
    Harrop JS , O’Toole JE , Steinmetz MP , et al . P-15 peptide enhanced bone graft in transforaminal lumbar interbody fusion: a randomized, controlled, investigational device exemption study demonstrating improved composite clinical success. Spine (Phila Pa 1976). 1976;51(4):238–247. 10.1097/BRS.0000000000005579
  38. 38.
    ↵
    Harrop JS , Steinmetz MP , O’Toole JE , et al . P-15 peptide enhanced bone graft improves time to fusion in transforaminal lumbar interbody fusion: a randomized, controlled, investigational device exemption study. Spine (Phila Pa 1976). 1976;51(4):229–237. 10.1097/BRS.0000000000005580
  39. 39.
    ↵
    Class 2 Device Recall: PearlMatrix P-15 Peptide Enhanced Bone Graft. Recall Z-1165-2026; Event ID 98242. U.S. Food and Drug Administration. January 23, 2026.
  40. 40.
    ↵
    Duan R , van Dijk LA , Barbieri D , de Groot F , Yuan H , de Bruijn JD . Accelerated bone formation by biphasic calcium phosphate with a novel sub-micron surface topography. Eur Cell Mater. 2019;37:60–73. 10.22203/eCM.v037a05
  41. 41.
    ↵
    van Dijk LA , Janssen NG , Nurmohamed SJ , et al . Osteoinductive calcium phosphate with submicron topography as bone graft substitute for maxillary sinus floor augmentation: a translational study. Clin Oral Implants Res. 2023;34(3):177–195. 10.1111/clr.14028
  42. 42.
    ↵
    Duan R , Zhang Y , van Dijk L , et al . Coupling between macrophage phenotype, angiogenesis and bone formation by calcium phosphates. Mater Sci C Mater Biol Appl. 2021;122:111948. 10.1016/j.msec.2021.111948
  43. 43.
    ↵
    Guo X , Li M , Qi W , et al . Serial cellular events in bone formation initiated by calcium phosphate ceramics. Acta Biomater. 2021;134:730–743. 10.1016/j.actbio.2021.07.037
  44. 44.
    ↵
    Stempels HW , Lehr AM , Delawi D , et al . Efficacy of biphasic calcium phosphate ceramic with a needle-shaped surface topography versus autograft in instrumented posterolateral spinal fusion. Spine (Phila Pa 1976). 2024;49(19):1323–1331. 10.1097/BRS.0000000000005075
  45. 45.
    ↵
    Griffoni C , Tedesco G , Canella V , et al . Ceramic bone graft substitute (mg-HA) in spinal fusion: a prospective pilot study. Front Bioeng Biotechnol. 2022;10:1050495. 10.3389/fbioe.2022.1050495
  46. 46.
    ↵
    Use of the Bone Substitute SintLife® in Vertebral Arthrodesis Procedures: A Pilot Study. ClinicalTrials.gov. ID NCT03407560.
  47. 47.
    ↵
    American Medical Association/Specialty Society RVS Update Committee . January 2017 RUC Meeting Minutes. Bone Marrow Aspiration (Tab 6). American Medical Association.
  48. 48.
    ↵
    O’Toole JE , Sasso RC , Harrop JS , et al . Adverse impact of obesity on lumbar spine fusion, patient-reported outcomes and costs: a systematic review and meta-analysis. Spine (Phila Pa 1976). 2025;50(17):1208–1218. 10.1097/BRS.0000000000005395
  49. 49.
    ↵
    American Medical Association . CPT® 2026 Professional Edition. Chicago, IL: American Medical Association; 2025.
  50. 50.
    ↵
    International Society for the Advancement of Spine Surgery . 2026 CPT® Code Updates for Spine Surgery. International Society for the Advancement of Spine Surgery. January 26, 2026. https://isass.org/2026-cpt-code-updates-for-spine-surgery/. 30 August 2026.
View Abstract
Loading
Loading

ISASS27 Annual Conference at Loews Miami Beach Hotel, April 23-25, 2027