Learns more about the ioverame dials branch treatments

Feasibility of Intraoperative Anterior Reduction for the Treatment of Grade II Spondylolisthesis: A Biomechanical Investigation

  • International Journal of Spine Surgery
  • October 2026,
  • 8937;
  • DOI: https://doi.org/10.14444/8937

Abstract

Background Spondylolisthesis is a common cause of lower back pain, often accompanied by spinal stenosis, disc degeneration, and altered biomechanics. Reduction is achieved anteriorly through anterior lumbar interbody fusion (ALIF) or posteriorly through pedicle screws/rods. ALIF allows for favorable biomechanics for fusion but has limited reduction capability in high-grade slips. Anterior reduction allows for increased slip reduction without relying on spacer impaction but has only been explored in grade I spondylolistheses. The objective of this study was to evaluate the reduction capacity of an integrated ALIF spacer with a novel built-in anterior reduction mechanism in a simulated grade II spondylolisthesis model.

Methods Spondylolistheses were simulated in 5 fresh-frozen cadaveric lumbar segments (L4–L5) with slips at the high end of the grade II range (50% ± 5% anterior slip) via a combination of partial discectomy, facet joint loosening, and dynamic shear. Specimens were treated with ALIF spacers with a built-in anterior reduction mechanism under physiological load, and incremental reduction was recorded during each procedural step.

Results Discectomy reduced the spondylolistheses from 46.6% ± 3.0% slip to 39.6% ± 12.4% slip (P = 0.926). Spacer insertion, representing traditional ALIF, reduced this to 22.0% ± 10.3% slip (P = 0.683 vs discectomy). Meanwhile, the anterior reduction mechanism reduced the remaining slip to 3.0% ± 3.7% (P = 0.05 vs insertion).

Conclusions Each procedural step incrementally contributed to slip reduction. The majority of correction was attributable to the anterior reduction mechanism, demonstrating a potential benefit over the traditional ALIF approach. Future clinical testing is necessary to determine the impact on patient outcomes.

Clinical Relevance Slip reduction of higher-grade spondylolistheses allows for more anatomical alignment and favorable biomechanics for fusion. The ability to achieve such reduction via an anterior approach minimizes the risks of pedicle screw pullout from posterior approaches and still allows for circumferential fixation via posterior pedicle screws.

Introduction

Originally described by an obstetrician in 1782, spondylolisthesis is a common condition causing back and leg pain among those it affects.1 The condition involves the anterior slippage or “listhesis” of a vertebral body in relation to its next caudal counterpart. It is often accompanied by spinal stenosis, segmental instability, facet capsule disruption, altered biomechanics, loss of the natural lumbar lordosis, and disc degeneration, which increases the risk of nerve impingement.2,3 Spondylolisthesis afflicts up to 20% of the adult population, and this is expected to increase in the United States as aging patients begin to experience degenerative changes exacerbating existing slippage.3 Causes can range from a variety of factors, including degenerative changes to the disc and facets, compromised pars interarticularis, high-impact trauma, congenital deformity, or progressive pathologies, each resulting in a distinct etiology.4 Lower back pain, motor weakness, and sensory deficits are the most common complaints among patients caused by spinal or foraminal stenosis, accompanied by the progression of the slip.5,6

The severity and treatment options for spondylolistheses are often determined by the degree of anterior slip using the Meyerding classification. Grade I is defined as <25% slip, grade II is 25% to 50% slip, grade III is 50% to 75% slip, grade IV is 75% to 100% slip, and grade V or spondyloptosis is >100% slip.7 Most spondylolistheses are low grade (grade I) and asymptomatic, and many can be treated nonoperatively; however, some can be recalcitrant to nonoperative therapy or progressive as patients age, leading to worsening symptoms.8 Between 10% and 15% of younger patients with low-grade spondylolisthesis will fail conservative treatment and require surgery.9 Additionally, higher-grade spondylolistheses (grades III and IV) make up 11.3% of cases and are typically accompanied by permanent nerve dysfunction or severe degeneration, often requiring surgery.10,11

Due to the variety of factors affecting the condition, there is a lack of consensus on how best to treat spondylolistheses. Depending on patient symptoms and the amount of slip, treatment can vary between decompression, instrumented or noninstrumented fusion, or slip reduction and fusion.8 Intraoperative slip reduction can be achieved anteriorly through anterior lumbar interbody fusion (ALIF) or posteriorly through pedicle screws and rods, with or without transforaminal lumbar interbody fusion. ALIF offers the benefits of a large, stable footprint for fusion, as well as restoration of disc height, lordosis restoration, passive slip reduction through spacer impaction, and elevation of the cranial segment, but this is supplemented to provide circumferential fixation for added stability.12 Posterior-only approaches allow for direct decompression and slip reduction via a cantilever technique, with or without interbody fusion, and have long been used for treating spondylolisthesis; however, this puts greater stress on the pedicles during reduction and carries a higher risk of screw pullout, especially for patients with higher-grade slips and poor bone quality.8,13,14 In addition, technical difficulties may arise in higher-grade spondylolisthesis in gaining clearance for interbody fusion placement among already stretched, compressed traversing nerve roots. Superior clinical outcomes have been previously reported with circumferential fixation through a combined anterior/posterior approach.15

Recent studies have found that patients with degenerative grade I spondylolistheses can be treated through fusion with static ALIF with sufficient slip reduction.16 This may be attributed to the fact that low-grade spondylolistheses partially reduce when patients are placed in the supine position. Tarpada et al found that in 69.5% of cases, low-grade spondylolistheses reduced from 17.15% to 13.67% slip when patients were moved from the upright neutral position to supine.17 However, this has not been reported in higher-grade spondylolistheses. Instrumented slip reduction also allows for benefits such as the restoration of global spinopelvic balance and favorable biomechanics for fusion, which are not always possible with in situ fusion alone.11,12,18 To this end, interbody spacers with built-in anterior reduction technology have emerged to maximize slip reduction without solely relying on spacer impaction or subjecting the pedicles to high stress via posterior reduction and risk of pullout. So far, built-in anterior reduction mechanisms have only been explored for treating grade I spondylolistheses, demonstrating superior reduction capacity compared with posterior-based reduction approaches, but their viability in treating higher-grade slips has yet to be explored.19 Therefore, the purpose of this cadaveric study was to evaluate the feasibility of using an ALIF spacer with an integrated plate and a built-in anterior reduction mechanism to reduce a simulated intraoperative grade II spondylolisthesis. The reduction capacity of the spacer was evaluated with this cadaveric model, and radiographic analysis and visual inspection were used to assess for evidence of implant or specimen failure.

Methods

Specimen Preparation

Five fresh-frozen cadaveric single-level lumbar segments (L4–L5; 2 men and 3 women; age: 46.2 ± 8.6 years; T score: −0.6 ± 1.9) were used in this study. The medical history and radiographic images of each donor were reviewed, and specimens with spinal trauma, malignancy, deformity, or fracture that would otherwise affect the results were excluded. Each specimen had a dual-energy x-ray absorptiometry scan performed to quantify bone mineral density. Specimens with a range of bone mineral densities were tested to ensure there was no bias in the spondylolisthesis model due to bone quality. Each functional spinal unit (FSU) was carefully dissected, leaving only ligaments, vertebral bodies, and intervertebral discs. Specimens were fixed at both ends of the motion segment by a 1:1 mixture of Bondo Body Filler (Bondo MarHyde Corp.) and fiberglass resin (Home-Solution All Purpose, Bondo MarHyde Corp.). All specimens were double wrapped in saline-soaked gauze, stored at −20°C, and removed for thawing at least 12 hours before testing.

Test Setup

Spondylolisthesis Model

Spondylolisthesis simulation consisted of 3 steps until a permanent anterior slip was achieved: (1) simulated posterior instability; (2) simulated disc degeneration; and (3) dynamic shearing. First, the posterior column was destabilized to represent a common clinical scenario for nontraumatic high-grade slips involving a combination of dysplastic “loose” facets with subsequent degeneration.20–24 This scenario of dysplastic/degenerative spondylolisthesis was chosen as high-grade slips are not typically observed with degenerative spondylolisthesis alone but require combinational factors such as congenital predisposition to slip due to lamina/facet orientation and/or trauma to the pars interarticularis.11,25

In this model, facet joints were loosened, and the capsule ligament released to allow for anterior translation of the superior vertebra, mimicking a mild case of unstable dysplastic spondylolisthesis.20,22–24 This goal was accomplished by carefully widening the joint capsule between the articular processes with a scalpel until they could slide under applied shear. Next we provided controlled release of the interspinous and supraspinous ligaments to simulate posterior ligament laxity that is often observed with high-grade spondylolistheses.11,26 Preliminary testing revealed this as necessary, as these ligaments often broke during dynamic shear, so they were pre-emptively released to avoid damage to the bone and allow for 50% slip. Disc degeneration was simulated by a nucleotomy performed bilaterally to the anterior longitudinal ligament with the removal of 50% of the center disc. This amount was estimated via radiography during the nucleotomy and was necessary to allow for decreased shear resistance and anterior slip. Preliminary testing revealed that >50% disc removal resulted in increased disc loading with negligible vertebral body shearing. The anterior longitudinal ligament was left intact to simulate its in vivo function as a stabilizer against anterior slip and was fatigued during cyclic loading to induce ligament laxity necessary for a grade II spondylolisthesis to occur.

Spinopelvic alignment and intradiscal loads are important mechanisms for inducing clinically relevant anterior slip and subsequent spondylolisthesis.27–31 In this study, a custom-built fixture assembly was used to position each specimen and apply axial compression (250 N) to simulate the intraoperative follower load running through the longitudinal axis of the spine while in the supine position (Figure 1).32,33 In this fixture, the inferior vertebra was fixed, while the superior vertebra was free to move with unconstrained linear motion in the anterior-to-posterior plane along a rail. This allowed for a controlled reduction of spondylolisthesis under simulated axial loading conditions. Anterior slip was confirmed and quantified using lateral radiographs (Figure 2).

Figure 1

Custom-built fixture for static axial compression of an L4–L5 functional spinal unit with a grade II spondylolisthesis.

Figure 2

Lateral fluoroscopic image of an L4–L5 functional spinal unit following spondylolisthesis creation. Anterior-posterior (AP) diameter (bottom line) of the inferior vertebra (L5) and anterior displacement of the posterior corner of the superior vertebra’s endplate (L4) (top line). Grade II spondylolisthesis was achieved once the anterior displacement (mm) was 50% ± 5% of the total AP diameter of the inferior vertebral endplate.

Prior to spondylolisthesis creation, photographs and lateral radiographs were obtained with the intact specimens mounted in the custom fixture (Figure 1) in the supine position under a physiological compressive load.9,10 These served as baselines to determine the amount of anterior slip achieved following spondylolisthesis model creation. The Meyerding classification method was used to quantify spondylolistheses, where the anterior displacement of the posterior corner of the superior vertebra’s endplate (L4) along the anterior-posterior (AP) diameter of the L5 endplate was recorded (Figure 2). The amount of anterior slip required to create a grade II spondylolisthesis was calculated for each specimen based on the L5 AP diameter. To test a worst-case grade II spondylolisthesis model, a slip of 50% ± 5% anterior displacement of the L5 AP diameter was used. The following equation was used to determine anterior slip following spondylolisthesis model creation:

Equation 1: slip (%) = (anterior displacement/L5 AP diameter) × 100.

Specimens were mounted into the custom-built test fixture in the prone position and fixed onto an MTS 858 Mini Bionix load frame (MTS Systems Corporation, Eden Prairie, MN, USA). The fixture allowed static axial compression to be applied to the single-level lumbar segment, while the MTS applied dynamic shear to achieve direct anterior translation of the superior vertebra (Figure 3). These conditions were meant to induce a spondylolisthesis under simulated physiological loading conditions. A displacement-control cyclic shear protocol was used to induce anterior slippage of the superior vertebra (~50%) at a rate of 1 Hz under static axial compression (250 N) as measured by an I-Scan tactile pressure mapping system (Evolution Handle, TekScan, Inc., Norwood, MA, USA). Dynamic shearing was performed in 1 hour increments until a grade II spondylolisthesis was achieved. Specimens were sprayed periodically with saline (0.9%) throughout testing to preserve the viscoelastic properties of the discs and ligamentous structures.

Figure 3

L4–L5 functional spinal unit on MTS load frame during spondylolisthesis model creation. The fixture allows the spine to be in dynamic shear to induce spondylolisthesis while under axial compression, simulating the in vivo conditions in the supine position.

Following cyclic shearing, specimens were reoriented into the supine position in the test fixture on a radiolucent table (Figure 1). Lateral radiographs were taken of the spondylolisthesis under axial compression to verify anterior slip. If a grade II spondylolisthesis was not produced, the specimen was fatigued for another hour with displacements increased by 2 to 3 mm and re-evaluated radiographically in the supine position. This process was repeated until an anterior slip of 50% ± 5% was achieved.

Biomechanical Testing

Following grade II spondylolisthesis creation, anterior slip and axial loads measured at the end of spondylolisthesis creation were retained for each specimen as it was flipped into the supine position. All subsequent procedural steps, including discectomy, spacer insertion, and anterior reduction, were performed under load control using this retained load. This allowed for a controlled measure of slip reduction between procedural steps. Additionally, this approach offered a means to replicate the surgical scenario as closely as possible, starting with the spondylolisthesis in a similar loading state as in vivo while avoiding sudden over-reduction due to a catastrophic loss in load or a lack of reduction due to an excessive buildup of compression that prevents natural distraction of the disc space during spacer insertion. Following a thorough discectomy, specimens were implanted with an appropriately sized ALIF spacer with an integrated plate and a built-in anterior reduction mechanism (MONUMENT, Globus Medical, Inc., Audubon, PA, USA) per the implant’s recommended surgical technique.

This implant utilizes a leadscrew mechanism to translate radial motion of a torque-limiting driver into anterior translation of a medial integrated plate to apply anterior reduction. When the translation mechanism is fully extended during insertion, it extends 8 mm past the anterior edge of the fully collapsed spacer. This built-in reduction feature allows for continuous translation up to 8 mm but does not require complete reduction. Whether the implant spacer is fully reduced 8 mm or partially reduced, the translation is locked with a self-locking feature that does not require any additional steps for locking. An internal polyetheretherketone ring provides resistance to the leadscrew to ensure that the position of the medial plate is retained when not actively translated by the driver. Lateral radiographs were taken to quantify slip in the supine position following spondylolisthesis creation, discectomy, spacer insertion, and reduction using the reduction mechanism (Figure 4). This was done to determine how much correction was achieved at each procedural step of the simulated surgical procedure. The slip that remained after each step was measured as previously stated using these radiographs and reported as a percentage of the AP distance of the inferior vertebra.

Figure 4

Lateral fluoroscopic image of lumbosacral specimen following (A) spondylolisthesis creation, (B) discectomy, (C) spacer insertion, and (D) reduction via the spacer’s built-in mechanism.

Failure Analysis

Pre- and postoperative lateral radiographs were taken of the specimen in the test fixture in supine position, followed by visual inspection of the tested specimens and implants for evidence of failure. All specimens were assessed for evidence of screw breakage, breakage of the spacer’s built-in reduction mechanism, vertebral body fracture, and bone screw pullout. Relevant specimen data, such as dual-energy x-ray absorptiometry score and percent reduction achieved by the spacer, were also analyzed.

Statistical Analysis

Statistical analysis was performed using SPSS Statistics (version 22; IBM Corp., Armonk, NY, USA). A repeated-measures analysis of variance was used to evaluate differences in the reduction capacity (amount of slip) of each procedural step (spondylolisthesis, discectomy, spacer insertion, and reduction mechanism). A second repeated-measures analysis of variance was used to evaluate differences in the contribution of each procedural step to the total slip reduction achieved. Significant findings were followed up with a Bonferroni post hoc, with significance defined as P < 0.05 for all tests. Descriptive statistics of any failure mechanisms, including screw pullout, vertebral body fracture, screw breakage, or breakage of the spacer’s built-in reduction mechanism, were reported.

Results

Spondylolisthesis Correction

Specimen information is shown in Table 1. On average, these specimens had an average age of 46.2 ± 8.6 years and an average T score of −0.6 ± 1.9.

View this table:
Table 1

Specimen information and implant profiles.

The results of spondylolisthesis correction testing are shown in Figure 5 and Table 2. The steps of the simulated surgical procedure did have a significant effect on anterior slip (P < 0.001), with incremental reduction observed after each procedural step. On average, the grade II spondylolisthesis model started with 46.6% ± 3.0% slip. Discectomy reduced this to 39.6% ± 12.4% slip (P = 0.926), spacer insertion further reduced this to 22.0% ± 10.3% slip (P = 0.683 vs discectomy), and the built-in anterior reduction mechanism reduced the remaining slip to 3.0% ± 3.7% (P = 0.05 vs spacer insertion). Significant reductions from the initial slip were only observed after spacer insertion (P = 0.043) and the built-in anterior reduction mechanism (P = 0.002). Additionally, significant reductions in slip after the discectomy step were only seen after the anterior reduction mechanism was used (P = 0.027; Table 3). We also noted an increased resistance to reduction as the spondylolisthesis was reduced. This finding is common in clinical practice, where reduction becomes increasingly difficult in the final percentages of reduction.

Figure 5

Anterior slippage after each procedural step normalized as a percentage of the L5 anteroposterior (AP) diameter (100%).

View this table:
Table 2

Anterior slippage that remains after each step of the technique (AVG ± SD).

View this table:
Table 3

Results of the 1-way ANOVA with repeated measures and Bonferroni correction comparing differences between procedural steps and anterior slip.

Contributions to Total Correction

There was no significant effect of the procedural steps of the simulated surgery on their contributions to the total reduction achieved (P = 0.494); however, each procedural step contributed to slip reduction, with the majority of correction achieved attributable to the built-in reduction mechanism, as shown in Figure 6 and Table 4. On average, discectomy provided 18.6% ± 25.6% of the total correction achieved by the surgical technique. Meanwhile, spacer insertion provided 36.6% ± 47.0% of the total correction, and the built-in reduction mechanism provided 44.8% ± 24.3% of the total correction. The average slip reduction was 2.7 mm following discectomy, 5.8 mm following spacer insertion, and 6.8 mm following anterior reduction, for a total of 15.3 mm of reduction.

Figure 6

The contribution of each procedural step to the total correction achieved by the surgical technique as a percentage of the total slip correction achieved (100%).

View this table:
Table 4

Contributions of each procedural step to total slip correction.

Failure Analysis

No instances of screw breakage, breakage of the built-in reduction mechanism, or vertebral body fracture were observed in the radiographs, photos, or upon physical examination of any of the specimens and implants. There were no instances of caudal screw pullout.

Discussion

Spondylolisthesis is a growing problem that is a large source of pain and disability for patients, yet ideal treatment remains controversial despite a wealth of literature in the space. There is a lack of consensus on the best practice for treatment, with surgeons split between whether to intraoperatively reduce prior to fusing or just fuse. Slip reduction helps to reestablish spinopelvic balance, restore endplate-to-endplate coverage for a larger fusion graft, and provide a biomechanical environment favorable for fusion.11,12,18,34,35 Anterior and posterior approaches to slip reduction and fusion are both widely used, but a combined approach with circumferential fixation has been shown to provide superior patient outcomes.15,34 Anterior reduction mechanisms offer the prospect of more reduction than traditional ALIF without posterior reduction, while also providing the same sagittal correction and stability when used with circumferential fixation, but have so far only been investigated in a grade I spondylolisthesis model.19 In addition, anterior reduction via this technique further opens the possibility of minimally invasive posterior pedicle screw fixation rather than potentially more morbid open approaches seeking posterior reduction. This study investigated the feasibility of using intraoperative anterior reduction via an integrated ALIF spacer with a built-in reduction mechanism to treat a grade II spondylolisthesis in a cadaveric model.

The present study found an incremental reduction with each procedural step. Discectomy reduced the anterior slip by 16%, spacer insertion reduced it by another 36%, and anterior reduction reduced the slip by 42% for a total of 94% or 15.3 mm of reduction. Interestingly, the greatest reductions in slip were attributed to spacer insertion (36.6% total reduction) and the anterior reduction mechanism (44.8% total reduction), with discectomy showing the greatest variability in its contributions. No instances of implant or specimen failure were observed; however, 1 specimen experienced caudal screw migration during initial spacer reduction. This was attributed to improper screw alignment following spacer insertion. Further reduction caused these screws to reorient back into proper alignment, likely due to the counterforce exerted by the reduction, regaining fixation, and allowing anterior reduction to be achieved by the reduction mechanism.

Together, the discectomy and spacer insertion steps simulate a traditional static ALIF, which intraoperatively reduced the grade II spondylolisthesis by more than 50% from a 45% slip to a 22% slip. This reduction to a grade I spondylolisthesis supports the consensus that grade I spondylolisthesis can be reduced by traditional ALIF.16,36 The anterior reduction mechanism provided nearly 7 mm more reduction (42%), almost completely correcting the remaining slip. Anterior reduction via the reduction mechanism was also less variable than the discectomy and spacer insertion steps despite load control. This finding is likely due to the relatively controlled nature of the reduction in this step, which is administered by a torque-limiting driver as opposed to disc removal or spacer impaction. Nevertheless, the cumulative reduction achieved was a function of all procedural steps, which should be considered. Each step incrementally provided slip reduction, which cumulated to the total correction. In a clinical setting, this would be followed by the application of supplemental fixation.

Limitations

There were several limitations in this study due to the nature of this injury and the limits of biomechanics testing. First, all testing was conducted with a limited number of relatively nondegenerated spines without a native L4 to L5 spondylolisthesis or the common anatomical compensatory mechanisms (eg, bone erosion, disc desiccation, and facet joint loosening).35 This process was used to ensure that all spondylolistheses were as comparable between specimens as possible and, as such, anterior slip was induced in a controlled manner while trying to replicate in vivo circumstances as best as possible; however, even this proved to be a challenge with the limited literature available on the complex biomechanics of the spine in spondylolisthesis. While specimens with a range of T scores were tested, the majority were nonosteoporotic, as shown in Table 1. Although not observed in this study, screw pullout during anterior reduction remains a risk that is increased with poor bone quality, but was not the focus of this study, which investigated whether anterior reduction technology could reduce grade II spondylolistheses but should be explored in future studies. These specimens were also FSUs, which may not capture the complex compensatory effects from adjacent levels, which are known to be important for spondylolisthesis, but this approach was necessary from a practicality standpoint for this model.

Additionally, radiographic parameters such as disc height, foraminal height, and segmental lordosis are all important factors that were not explored as they were outside the scope of this study. These parameters provide insight into spinal alignment and the amount of indirect decompression meant to relieve neurological symptoms, which could not be investigated directly in this study. Such radiographic parameters and risk of neurological complications should be investigated in future biomechanical and clinical studies, respectively.

Another limitation of this study was that the model necessitated the spine to be in axial compression, which may limit the amount of change in lordosis upon insertion of the ALIF spacer. This limitation was partially addressed with the load control aspect of this model, which allowed for the distraction of the disc space during spacer insertion and reorientation of the vertebrae while still being under load to retain the slip. Again, due to the lack of literature in the space, these loads may not necessarily represent those found in patients but were based on previous studies and observations of how forces through the spine change in response to anterior slip. Preliminary testing revealed that axial load through the L4 to L5 model decreased by an average of 30.7% ± 11.4% as the FSU became more unstable and anterior slip was achieved. This observation was similar to one by Liu et al, where the authors observed decreases in intradiscal pressure in an L4 to L5 FSU ranging from 5% to 41% less than intact as a result of spondylolisthesis and served as a reference for load control during the procedure.37

The grade II spondylolisthesis model used in this study also required posterior releases, which may not accurately replicate the situation that occurs in many cases of adult degenerative spondylolisthesis, where there may be no posterior spondylolysis; however, literature review and preliminary mechanical testing revealed that sufficient posterior ligament laxity is required to achieve the degree of slip seen in clinical cases of high grade II degenerative spondylolistheses. Biomechanical stability is also a key factor to consider for fusion, which is often the end goal of spondylolisthesis treatment. While not elaborated on in our study, a wealth of cadaveric and clinical studies have already demonstrated the practicality of ALIF spacers supplemented with posterior pedicle screw fixation to treat spondylolistheses with favorable biomechanics and clinical outcomes even postreduction.15,16,19,34,36 While the focus of this study was to evaluate the feasibility of reducing a grade II spondylolisthesis through anterior reduction, it should be noted that the ALIF device utilized is only indicated to be used with supplemental fixation, which should always be used for optimal stability. Postreduction stability was not measured in this cadaveric study and should be considered in a clinical setting.

Finally, this study also did not compare reduction capacity between anterior and posterior approaches because it was previously done in a grade I spondylolisthesis model and outside the scope of this study, which was to determine if anterior reduction mechanisms could add benefit to existing ALIF techniques.19 Nevertheless, this should be explored in future studies.

Conclusions

Spondylolisthesis remains an ever-growing problem for patients, and treatment remains a topic of controversy. Intraoperative slip reduction provides the benefits of restoring spinopelvic alignment and biomechanics conducive to fusion. Anterior and posterior approaches to slip reduction are commonly employed, with anterior approaches utilizing ALIF and offering improved disc height and lordosis restoration, and posterior approaches providing direct decompression but carrying a greater risk of screw pullout.13 This study investigated the additive benefit of anterior reduction technology to supplement ALIF in the reduction of grade II spondylolisthesis in a cadaveric model, prior to the application of supplemental fixation. Anterior slip was reduced from 47% ± 3% initial slip to 3% ± 4% final slip on average with this technique. Each step of the surgical technique reduced the anterior slip incrementally, with the spacer’s built-in reduction mechanism contributing the most to slip reduction. Future clinical studies incorporating supplemental fixation into the final construct will be needed to determine the impact of this finding on patient outcomes.

Footnotes

  • Funding All funding for this study was provided by Globus Medical, Inc.

  • Declaration of Conflicting Interests D.R. receives consulting fees from Globus Medical, Inc. (GMI), Orthofix, SI Bone, and Stryker, as well as payments for lectures and presentations by GMI and Zimmer Biomet. J.P.M., M.M., J.M.M., and B.S.B. are paid employees of GMI and also receive stock options. G.P. was a paid co-op for GMI at the time of this study. D.Y. has no conflicts to disclose.

  • Disclosures J.P.M., M.M., J.M.M., and B.S.B. are salaried employees of the company that manufactures the devices used in this study. Additionally, D.R. receives consulting fees from this company as well as Orthofix, Stryker, and SI Bone. G.P. was a paid co-op of the company throughout the duration of this study.

References

  1. 1.
    ↵
    Bernard F, Mazerand E, Gallet C, Troude L, Fuentes S. History of degenerative spondylolisthesis: from anatomical description to surgical management. Neurochirurgie. 2019;65(2–3):75–82. 10.1016/j.neuchi.2019.03.006
  2. 2.
    ↵
    Beck AW, Simpson AK. High-grade lumbar spondylolisthesis. Neurosurg Clin N Am. 2019;30(3):291–298. 10.1016/j.nec.2019.02.002
  3. 3.
    ↵
    Konieczny MR, Jäger M. Spondylolisthesis. Orthopadie (Heidelb). 2023;52(11):931–940. 10.1007/s00132-023-04443-w
  4. 4.
    ↵
    Wiltse LL, Newman PH, Macnab I. Classification of spondylolisis and spondylolisthesis. Clin Orthop Relat Res. 1976;(117):23–29.
  5. 5.
    ↵
    Floman Y. Progression of lumbosacral isthmic spondylolisthesis in adults. Spine (Phila Pa 1976). 2000;25(3):342–347. 10.1097/00007632-200002010-00014
  6. 6.
    ↵
    Hu SS, Tribus CB, Diab M, Ghanayem AJ. Spondylolisthesis and spondylolysis. J Bone Joint Surg Am. 2008;90(3):656–671.
  7. 7.
    ↵
    Koslosky E, Gendelberg D. Classification in brief: the Meyerding classification system of spondylolisthesis. Clin Orthop Relat Res. 2020;478(5):1125–1130. 10.1097/CORR.0000000000001153
  8. 8.
    ↵
    Tomé-Bermejo F, Piñera AR, Alvarez L. Osteoporosis and the management of spinal degenerative disease (II). Arch Bone Jt Surg. 2017;5(6):363–374.
  9. 9.
    ↵
    Tenny S. Spondylolisthesis. Spondylolisthesis. StatPearls; 2024.
  10. 10.
    ↵
    Kalani MA, Kouloumberis P, Richards AE, Lyons MK, Davila VJ, Neal MT. Retrospective radiographic analysis of anterior lumbar fusion for high grade lumbar spondylolisthesis. J Spine Surg. 2020;6(4):650–658. 10.21037/jss-20-597
  11. 11.
    ↵
    Kunze KN, Lilly DT, Khan JM, et al. High-grade spondylolisthesis in adults: current concepts in evaluation and management. Int J Spine Surg. 2020;14(3):327–340. 10.14444/7044
  12. 12.
    ↵
    Tu K-C, Shih C-M, Chen K-H, et al. Direct reduction of high-grade lumbosacral spondylolisthesis with anterior cantilever technique - surgical technique note and preliminary results. BMC Musculoskelet Disord. 2021;22(1):559. 10.1186/s12891-021-04439-7
  13. 13.
    ↵
    Boos N, Marchesi D, Zuber K, Aebi M. Treatment of severe spondylolisthesis by reduction and pedicular fixation. a 4-6-year follow-up study. Spine (Phila Pa 1976). 1993;18(12):1655–1661. 10.1097/00007632-199309000-00014
  14. 14.
    ↵
    Peng J-C, Guo H-Z, Zhan C-G, et al. Comparison of pedicle screw fixation with or without cement augmentation for treating single-segment isthmic spondylolisthesis in the osteoporotic spine. Sci Rep. 2023;13(1):827. 10.1038/s41598-023-27539-x
  15. 15.
    ↵
    Swan J, Hurwitz E, Malek F, et al. Surgical treatment for unstable low-grade isthmic spondylolisthesis in adults: a prospective controlled study of posterior instrumented fusion compared with combined anterior-posterior fusion. Spine J. 2006;6(6):606–614. 10.1016/j.spinee.2006.02.032
  16. 16.
    ↵
    Jesse CM, Schwarzenbach O, Ulrich CT, Häni L, Raabe A, Schär RT. Safety and efficacy of stand-alone anterior lumbar interbody fusion in low-grade L5-S1 isthmic spondylolisthesis. Brain Spine. 2022;2:100861. 10.1016/j.bas.2022.100861
  17. 17.
    ↵
    Tarpada SP, Cho W, Chen F, Amorosa LF. Utility of supine lateral radiographs for assessment of lumbar segmental instability in degenerative lumbar spondylolisthesis. Spine (Phila Pa 1976). 2018;43(18):1275–1280. 10.1097/BRS.0000000000002604
  18. 18.
    ↵
    Lak AM, Abunimer AM, Devi S, et al. Reduction versus in situ fusion for adult high-grade spondylolisthesis: a systematic review and meta-analysis. World Neurosurg. 2020;138(512–520):512–520. 10.1016/j.wneu.2020.03.030
  19. 19.
    ↵
    Hitchon PW, Mahoney JM, Harris JA, et al. Biomechanical evaluation of traditional posterior versus anterior spondylolisthesis reduction in a cadaveric grade I slip model. J Neurosurg. 2019;31(2):246–254. 10.3171/2019.2.SPINE18726
  20. 20.
    ↵
    Grobler LJ, Robertson PA, Novotny JE, Pope MH. Etiology of spondylolisthesis. assessment of the role played by lumbar facet joint morphology. Spine (Phila Pa 1976). 1993;18(1):80–91. 10.1097/00007632-199301000-00013
  21. 21.
    ↵
    Logroscino G, Mazza O, Aulisa G, Pitta L, Pola E, Aulisa L. Spondylolysis and spondylolisthesis in the pediatric and adolescent population. Childs Nerv Syst. 2001;17(11):644–655. 10.1007/s003810100495
  22. 22.
    ↵
    Łuczkiewicz P, Smoczyński A, Smoczyński M. The influence of the morphology of intervertebral facet joints on the development of the degenerative spondylolisthesis. Chir Narzadow Ruchu Ortop Pol. 2002;67(2):151–155.
  23. 23.
    ↵
    Sato K, Wakamatsu E, Yoshizumi A, Watanabe N, Irei O. The configuration of the laminas and facet joints in degenerative spondylolisthesis. a clinicoradiologic study. Spine (Phila Pa 1976). 1989;14(11):1265–1271. 10.1097/00007632-198911000-00022
  24. 24.
    ↵
    Toyone T, Ozawa T, Kamikawa K, et al. Facet joint orientation difference between cephalad and caudad portions: a possible cause of degenerative spondylolisthesis. Spine (Phila Pa 1976). 2009;34(21):2259–2262. 10.1097/BRS.0b013e3181b20158
  25. 25.
    ↵
    Saremi A, Goyal KK, Benzel EC, Orr RD. Evolution of lumbar degenerative spondylolisthesis with key radiographic features. Spine J. 2024;24(6):989–1000. 10.1016/j.spinee.2024.01.001
  26. 26.
    ↵
    Wang YXJ, Káplár Z, Deng M, Leung JCS. Lumbar degenerative spondylolisthesis epidemiology: a systematic review with a focus on gender-specific and age-specific prevalence. J Orthop Translat. 2017;11:39–52. 10.1016/j.jot.2016.11.001
  27. 27.
    ↵
    Boulay C, Tardieu C, Hecquet J, et al. Sagittal alignment of spine and pelvis regulated by pelvic incidence: standard values and prediction of lordosis. Eur Spine J. 2006;15(4):415–422. 10.1007/s00586-005-0984-5
  28. 28.
    ↵
    Jackson RP, Phipps T, Hales C, Surber J. Pelvic lordosis and alignment in spondylolisthesis. Spine (Phila Pa 1976). 2003;28(2):151–160. 10.1097/00007632-200301150-00011
  29. 29.
    ↵
    Labelle H, Roussouly P, Berthonnaud E, Dimnet J, O’Brien M. The importance of spino-pelvic balance in L5-S1 developmental spondylolisthesis: a review of pertinent radiologic measurements. Spine (Phila Pa 1976). 2005;30(6 Suppl):S27–S34. 10.1097/01.brs.0000155560.92580.90
  30. 30.
    ↵
    McGill SM, Hughson RL, Parks K. Changes in lumbar lordosis modify the role of the extensor muscles. Clin Biomech (Bristol). 2000;15(10):777–780. 10.1016/s0268-0033(00)00037-1
  31. 31.
    ↵
    Roussouly P, Gollogly S, Berthonnaud E, Labelle H, Weidenbaum M. Sagittal alignment of the spine and pelvis in the presence of L5-S1 isthmic lysis and low-grade spondylolisthesis. Spine (Phila Pa 1976). 2006;31(21):2484–2490. 10.1097/01.brs.0000239155.37261.69
  32. 32.
    ↵
    Nachemson AL. Disc pressure measurements. Spine (Phila Pa 1976). 1981;6(1):93–97. 10.1097/00007632-198101000-00020
  33. 33.
    ↵
    Sato K, Kikuchi S, Yonezawa T. In vivo intradiscal pressure measurement in healthy individuals and in patients with ongoing back problems. Spine (Phila Pa 1976). 1999;24(23):2468–2474. 10.1097/00007632-199912010-00008
  34. 34.
    ↵
    Bozzio AE, Johnson CR, Fattor JA, et al. Stand-alone anterior lumbar interbody, transforaminal lumbar interbody, and anterior/posterior fusion: analysis of fusion outcomes and costs. Orthopedics. 2018;41(5):e655–e662. 10.3928/01477447-20180711-06
  35. 35.
    ↵
    Rengachary SS, Balabhandra R. Reduction of spondylolisthesis. Neurosurg Focus. 2002;13(1):E2. 10.3171/foc.2002.13.1.3
  36. 36.
    ↵
    Rao PJ, Ghent F, Phan K, Lee K, Reddy R, Mobbs RJ. Stand-alone anterior lumbar interbody fusion for treatment of degenerative spondylolisthesis. J Clin Neurosci. 2015;22(10):1619–1624. 10.1016/j.jocn.2015.03.034
  37. 37.
    ↵
    Liu R, He T, Wu X, Tan W, Yan Z, Deng Y. Biomechanical response of decompression alone in lower grade lumbar degenerative spondylolisthesis--a finite element analysis. J Orthop Surg Res. 2024;19(1):209. 10.1186/s13018-024-04681-4
View Abstract
Loading
Loading

ISASS27 Annual Conference at Loews Miami Beach Hotel, April 23-25, 2027