Minimally Invasive Inline Spinopelvic Fixation Without Offset Connectors for Unstable Sacral Fractures: Technical Description and Preliminary Clinical Experience

  • International Journal of Spine Surgery
  • September 2026,
  • 8962;
  • DOI: https://doi.org/10.14444/8962

Abstract

Background Spinopelvic fixation (SPF) is widely used for unstable sacral fractures with spinopelvic dissociation; however, conventional constructs often require complex implant configurations and extensive soft-tissue dissection. We evaluated the feasibility and clinical outcomes of a minimally invasive SPF (MIS-SPF) technique using an inline construct without offset connectors for the treatment of unstable sacral fractures.

Methods The study included 5 consecutive patients with nonosteoporotic AO Spine Sacral Injury Classification Type C fractures who underwent MIS-SPF using an inline construct between September 2024 and March 2026. The construct consisted of lumbar pedicle screws connected to cranial iliac screws using bilateral longitudinal rods, whereas the caudal iliac screws were directly connected using a transverse rod. Perioperative variables, clinical outcomes, radiographic bone union, neurological recovery, and complications were retrospectively evaluated.

Results The mean operative time was 200.2 ± 87.5 minutes, and the mean estimated blood loss was 154.6 ± 76.9 mL. When limited to the L4–iliac SPF procedures, the mean operative time was 149.0 minutes. Four patients completed at least 12 months of follow-up. All achieved radiographic bony union and regained independent ambulation. The mean Gibbons score improved from 3.3 ± 0.5 preoperatively to 2.0 ± 0.0 at final follow-up. No implant failure, surgical site infection, or revision surgery was observed.

Conclusions In this preliminary case series, MIS-SPF using an inline construct without offset connectors was feasible and demonstrated encouraging short-term clinical and radiographic outcomes. Further comparative and biomechanical studies are warranted to clarify its role in the treatment of unstable sacral fractures.

Clinical Relevance This technical report describes a simplified minimally invasive SPF technique using an inline construct without offset connectors, which may facilitate surgical procedures while providing stable fixation for unstable sacral fractures.

Level of Evidence 4.

Introduction

AO Spine Sacral Fracture Classification includes types A, B, and C based on fracture morphology and instability, with type C representing the most unstable pattern characterized by loss of spinopelvic continuity.1 Specifically, C2 and C3 subtypes are highly unstable injuries involving bilateral vertical fractures or U-shaped sacral fractures and are commonly referred to as “suicidal jumper’s fractures.” Because these injuries are associated with both vertical and rotational instability, rigid fixation is generally required to facilitate early mobilization and fracture healing.2,3 Spinopelvic fixation (SPF) is widely used for C2/C3 sacral fractures because it provides strong stabilization by connecting the lumbar spine to the pelvis. However, conventional SPF techniques often require extensive soft-tissue dissection and complex implant constructs involving crosslinks and offset connectors, which may increase surgical invasiveness and wound-related complications. At our institution, we perform SPF using cannulated pedicle screws and 4 iliac screws (2 on each side). The cranial iliac screws are connected to the lumbar pedicle screws. In contrast, the caudal iliac screws are directly connected using a transverse rod, thereby creating an inline construct without offset connectors. This technique simplifies the construct and achieves a low-profile configuration while potentially improving surgical handling. In this study, we aimed to retrospectively evaluate the clinical outcomes and feasibility of this minimally invasive SPF (MIS-SPF) technique using an inline construct for unstable sacral fractures.

Methods

Between September 2024 and March 2026, 5 consecutive patients with nonosteoporotic unstable sacral fractures classified as AO Spine Sacral Injury Classification Type C underwent SPF using this minimally invasive inline construct at our institution. Patient demographics (age, sex, injury mechanism, and AO classification), perioperative factors (associated injuries, concomitant vertebral body fractures, preoperative transcatheter arterial embolization, temporary supra-acetabular external fixation, fixation range, sacral decompression, timing of surgery, operative time, and blood loss), clinical outcomes (Gibbons score,4 time to independent ambulation, and radiographic bone union), and postoperative complications were retrospectively reviewed. Radiographic bony union was defined as the presence of bridging trabecular bone across the fracture site on computed tomography along with the absence of progressive displacement, implant loosening, or implant failure. Perioperative outcomes were evaluated in all patients, and long-term follow-up was assessed in 4 patients with a minimum follow-up of 12 months. Final follow-up neurological findings were compared with those at initial presentation.

This study was approved by the Institutional Review Board of our institution. The requirement for informed consent was waived because of the retrospective nature of the study.

Surgical Technique

Patients were positioned prone, and approximately 7 to 8 cm longitudinal skin incisions were made bilaterally. Under fluoroscopic teardrop-view guidance, 4 iliac screws (2 on each side) were first inserted. Cannulated pedicle screws were then inserted at L4 and L5. The cranial iliac screws were connected to the lumbar pedicle screws using bilateral longitudinal rods, whereas the caudal iliac screws were directly connected using a transverse rod to reinforce horizontal pelvic and rotational stability. This configuration created an inline construct without using offset connectors (Figure 1). Fracture reduction was attempted using patient positioning, manual traction or compression, rod compression, and cantilever maneuvers, as deemed appropriate. Fracture alignment was assessed intraoperatively using fluoroscopy before final rod tightening. Because these reduction maneuvers have inherent limitations in severely displaced fractures, complete anatomical reduction is not always achievable. When satisfactory reduction could not be achieved, fixation was performed in situ. Additional sacral decompression was performed when persistent sacral canal compromise was considered responsible for neural compression. To minimize implant prominence, the iliac screws were inserted using a low-profile iliac screw trajectory, similar to those described for the low-profile S1-iliac trajectory5 and percutaneous modified iliac screw6 techniques. The entry point was positioned medial and ventral to the posterior superior iliac spine prominence, allowing a lower-profile construct without additional bone removal around the screw entry site. A single longitudinal incision connecting the lumbar and iliac screw entry sites was used on each side to facilitate rod handling and future implant removal.

Figure 1

Surgical technique of minimally invasive spinopelvic fixation using an inline construct without offset connectors. (A) Bilateral longitudinal skin incisions extending from the lateral aspect of the L4 pedicles to the superior aspect of the posterior superior iliac spine. (B) Under fluoroscopic teardrop-view guidance, 4 iliac screws (2 on each side) are inserted in a low-profile trajectory. (C) Cannulated pedicle screws are inserted at L4–L5. The cranial iliac screws are connected to the lumbar pedicle screws using bilateral longitudinal rods, whereas the caudal iliac screws are directly connected using a transverse rod, thereby creating an inline construct without offset connectors. Additional fixation can be added when concomitant vertebral fractures are present. (D) Postoperative anteroposterior radiograph demonstrating the completed inline construct.

Statistical Analysis

Descriptive statistics were used throughout. Continuous variables are expressed as mean ± SD with range. Categorical data are presented as n. Given the small sample size, no inferential statistics were applied.

Results

Patient Demographics and Injury Characteristics

Five consecutive patients (1 man and 4 women; mean age, 22.8 ± 5.0 years; range, 16–27 years) with unstable sacral fractures underwent SPF at our institution. Representative preoperative and postoperative images of all 5 cases are shown in Figure 2. All injuries resulted from high-energy falls from height. According to the AO Spine Sacral Injury Classification, 1 fracture was classified as type C2 and 4 as type C3. Concomitant vertebral body fractures were present in 2 patients. According to the AO Spine Thoracolumbar Injury Classification System, these included an L1 A3 incomplete burst fracture in case 3 and an L1 A1 fracture with an L2 A3 incomplete burst fracture in case 4. Anterior pelvic ring injuries were identified in 3 patients. All patients sustained associated lower-extremity injuries, including bilateral calcaneal fractures in 3 patients. One patient had a concomitant pneumothorax, and another had a hepatic injury. Three patients required preoperative transcatheter arterial embolization for pelvic hemorrhage control, and temporary supra-acetabular external fixation was applied preoperatively in 2 patients. Demographic and injury characteristics are summarized in Table 1.

Figure 2

Representative cases treated with minimally invasive spinopelvic fixation using the inline construct. Preoperative 3-dimensional computed tomography images and postoperative radiographs of cases 1–5 are shown in panels A/B, C/D, E/F, G/H, and I/J, respectively. Case 3 underwent additional T12–L2 fixation for a concomitant vertebral fracture, whereas case 4 required an extended T12–iliac construct with sacral decompression.

View this table:
Table 1

Patient demographics and injury characteristics (N = 5).

Surgical Procedure and Perioperative Course

SPF was performed at a mean of 9.6 ± 3.8 days after injury (range, 5–14 days). An SPF construct extending from L4 to the bilateral iliac wings was used in 3 patients. In case 3, additional T12–L2 posterior fixation using percutaneous pedicle screws was performed in the same session to address a concomitant L1 burst fracture. In case 4, which was complicated by an L1 A1 fracture and an L2 A3 incomplete burst fracture, the cranial extent of the construct was extended to T12, resulting in a T12–iliac construct. Sacral decompression was performed through a separate midline incision because of fracture displacement compromising the sacral canal. Since a midline approach had already been established, a crosslink was additionally placed in this early case. The operative times for the 5 cases were 158, 129, 205, 349, and 160 minutes, respectively, with a mean operative time of 200.2 ± 87.5 minutes (range, 129–349). When analysis was limited to the L4–iliac SPF procedure, excluding the additional T12–L2 fixation procedure in case 3 and the extended T12–iliac construct in case 4, the operative times were 158, 129, 149, and 160 minutes, respectively, with a mean operative time of 149.0 minutes. The mean estimated intraoperative blood loss was 154.6 ± 76.9 mL (range, 95–247 mL). No intraoperative complications, postoperative neurological deterioration, or surgical site infections were observed during the perioperative period. Operative details for each case are summarized in Table 2.

View this table:
Table 2

Operative details and perioperative outcomes of each case.

Long-Term Clinical and Radiographic Outcomes

Four patients (cases 1–4) completed a minimum follow-up of 12 months and were included in the long-term outcome analysis; the mean follow-up duration was 13.0 ± 1.4 months (range, 12–15 months). All 4 patients achieved radiographic bony union of the sacral fracture and regained independent ambulation at a mean of 58.0 ± 17.0 postoperative days (range, 36–75 days). The Gibbons score improved in every patient, from a preoperative mean of 3.3 ± 0.5 to 2.0 ± 0.0 at final follow-up. Two patients retained partial neurological deficits at final follow-up, including mild residual ankle weakness and sensory disturbance in case 2 and persistent left ankle paralysis with sensory disturbance in case 3. No patient required revision surgery, and no implant failure, loss of reduction, or pseudarthrosis was observed during follow-up. Elective implant removal was performed uneventfully in 3 patients (cases 2–4), whereas the remaining patient (case 1) was scheduled for implant removal at the time of analysis. Long-term outcomes are summarized in Table 3.

View this table:
Table 3

Long-term outcomes in patients with follow-up ≥12 mo (N = 4).

Discussion

In this study, MIS-SPF using an inline construct without offset connectors was applied for nonosteoporotic unstable sacral fractures caused by high-energy trauma, resulting in favorable clinical and radiographic outcomes. All patients achieved bony union and regained independent ambulation without implant-related complications, supporting the feasibility of this technique in this preliminary case series, with encouraging early clinical and radiographic outcomes.

Spinopelvic dissociation is a severe injury characterized by both vertical and rotational instability. Without appropriate treatment, progressive kyphotic deformity, chronic pain, neurological impairment, and gait dysfunction may occur.7 In particular, severe displacement has been associated with worse neurological and functional outcomes, and surgical stabilization is generally recommended.7 Recently, favorable outcomes have also been reported for less invasive fixation techniques confined to the pelvis, including percutaneous iliosacral screw fixation and transiliac transsacral screw (TITS) fixation.8–11 However, some of these reports include fragility fractures of the pelvis associated with low-energy trauma or osteoporosis, which differ pathophysiologically from true spinopelvic dissociation.12 In contrast, all patients in the present study had high-energy AO type C2/C3 injuries with complete disruption of spinopelvic continuity. In such highly unstable injuries, rigid stabilization using SPF is often required.13,14 Although SPF provides rigid stabilization, traditional open approaches require extensive soft-tissue dissection and have been associated with increased blood loss, wound infection, and soft-tissue complications. Schildhauer et al reported a 16% infection rate following open SPF.10,15 In addition, patients with spinopelvic dissociation frequently sustain multiple associated injuries, including spinal fractures, lower-extremity fractures, pelvic ring injuries, and thoracoabdominal injuries.16 Furthermore, patients with pelvic fractures requiring transcatheter arterial embolization have been reported to be at increased risk of gluteal necrosis and wound complications.10,17,18 Thus, MIS-SPF, which minimizes extensive soft-tissue dissection, may be considered a useful treatment strategy for these severely injured patients.

Recently, an increasing number of studies have reported favorable outcomes for MIS-SPF, including reduced blood loss and lower rates of wound complications compared with conventional open techniques. Koshimune et al reported that the introduction of MIS-SPF reduced operative time from 345 to 208 minutes and blood loss from 520 to 290 mL.19 Williams et al reported favorable perioperative outcomes in MIS-SPF cases, with a mean operative time of 144 minutes and a mean blood loss of 202 mL.20 Liu et al described robotic minimally invasive triangular osteosynthesis and demonstrated reductions in both blood loss (612 mL vs 142 mL) and operative time (185 minutes vs 148 minutes) compared with open procedures.21 Similarly, Pearson et al reported significantly lower blood loss in the MIS group compared with the open group (538 mL vs 171 mL).22 In the present study, the mean blood loss of 154.6 mL and the mean operative time of 149 minutes for the L4–iliac SPF procedures were comparable with values reported in previous MIS-SPF series. These findings suggest that the proposed construct can simplify implant assembly while maintaining perioperative outcomes comparable to existing MIS-SPF techniques.

Maintaining sufficient stability while preserving minimal invasiveness is a crucial challenge in MIS-SPF. Currently reported MIS-SPF construct concepts can largely be divided into 2 approaches. One emphasizes increased stability using crosslinks, offset connectors, and multirod constructs, including techniques such as crab-shaped fixation.19,23 Although these constructs provide strong fixation, the implant configuration becomes more complex. The other prioritizes minimally invasive techniques and procedural simplicity by simplifying the implant construct, such as crosslink-free triangular osteosynthesis or simplified constructs combined with TITS.24–26 However, these simplified constructs may provide insufficient rotational and horizontal stability, which could contribute to fixation failure or nonunion.18,24 In addition, TITS fixation may provide insufficient stability in severely displaced fractures or in cases with disrupted osseous fixation pathways.9 Previous MIS-SPF techniques have primarily focused on reducing surgical invasiveness through percutaneous instrumentation, indirect reduction maneuvers, and more recently through navigation- or robot-assisted techniques.21,25 In contrast, the primary objective of the present technique is not to further reduce surgical invasiveness or improve radiographic outcomes but to simplify construct assembly and surgical workflow. The procedure can be performed through small incisions using conventional fluoroscopic guidance without navigation, robotic assistance, or specialized instrumentation, providing a simple and reproducible surgical strategy.23 Unlike previously reported MIS-SPF techniques that use offset connectors to accommodate the mismatch between the longitudinal rod and iliac screw heads,19,23 direct inline alignment allows continuous rod fixation without additional connectors, thereby simplifying rod insertion and fixation procedures. We propose that sufficient construct stability could be maintained through continuous bilateral longitudinal rod fixation, whereas the transverse rod connecting the caudal iliac screws reinforces rotational and horizontal stability across the posterior pelvic ring. In addition, the overall system can be maintained in a low-profile configuration, which may reduce implant prominence and wound-related complications. A similar low-profile iliac screw concept has been described in the low-profile S1-iliac trajectory and percutaneous modified iliac screw techniques.5,6 In the present study, a low-profile iliac screw trajectory was used to minimize implant prominence. Unlike S2 alar-iliac (S2AI) screws, this trajectory is independent of the sacral osseous corridor and is therefore less likely to be affected by the degree of sacral fracture comminution. However, biomechanical evidence regarding this low-profile iliac screw trajectory remains limited, particularly with respect to pull-out strength and its influence on overall construct mechanics. Furthermore, because implant removal is often required in younger trauma patients, the simplified construct may facilitate secondary implant removal procedures. Unlike conventional crosslinks that connect bilateral rods, the transverse rod directly connects the caudal iliac screws. The use of a crosslink in case 4 represented an early technical modification after sacral decompression rather than the intended construct design, and routine crosslink augmentation is no longer part of our current surgical strategy. However, the present study was not designed to evaluate the mechanical superiority of this construct; further biomechanical validation is required to clarify its stabilizing effect.

This study has some limitations. First, although fracture reduction is an important factor influencing neurologic and radiographic outcomes, quantitative radiographic assessment of reduction quality and postoperative spinopelvic alignment was not systematically performed. In addition, preoperative standing radiographs could not be obtained because of the high-energy nature of these injuries. Consequently, the relationship between reduction quality, spinopelvic alignment, and clinical outcomes could not be evaluated. Second, this was a small retrospective study without a control group; therefore, superiority over conventional SPF techniques cannot be directly demonstrated. In addition, biomechanical evaluation of the present construct was not performed, and the rotational stability provided by the transverse rod configuration requires further investigation in future cadaveric and biomechanical studies. Nevertheless, consistently favorable clinical outcomes and a low complication rate were achieved, suggesting the feasibility and safety of this construct.

Conclusion

In this preliminary case series, MIS-SPF using an inline construct without offset connectors was feasible and demonstrated encouraging short-term clinical and radiographic outcomes. Further studies with larger cohorts, comparative designs, and biomechanical evaluation are required to establish its clinical role and mechanical characteristics.

Footnotes

  • Funding The authors received no financial support for the research, authorship, and/or publication of this article.

  • Declaration of Conflicting Interests The authors report no conflicts of interest in this work.

  • Patient Consent The requirement for informed consent was waived because of the retrospective nature of the study.

  • Ethics Approval This study was approved by the Institutional Review Board of Nagoya Ekisaikai Hospital.

  • Data Availability Statement Datasets generated and/or analyzed during the current study are available from the corresponding author on reasonable request.

  • Author Contributions K.U. conceptualized the study and drafted the manuscript. T.Aw., T.Ab., S.N., T.I., H.N., K.I., O.S., Y.N., and R.S. contributed to data collection and manuscript revision. All authors approved the final manuscript.

References

  1. 1.
    ↵
    Kweh BTS , Tee JW , Oner FC , et al . Evolution of the AO Spine sacral and pelvic classification system: a systematic review. J Neurosurg Spine. 2022;37(6):914–926. 10.3171/2022.5.SPINE211468
  2. 2.
    ↵
    Roy-camille R , Saillant G , Gagna G , Mazel C . Transverse fracture of the upper sacrum. Spine. 1985;10(9):838–845. 10.1097/00007632-198511000-00011
  3. 3.
    ↵
    Vaccaro AR , Kim DH , Brodke DS , et al . Diagnosis and management of sacral spine fractures. Instr Course Lect. 2004;53:375–385.
  4. 4.
    ↵
    Gibbons KJ , Soloniuk DS , Razack N . Neurological injury and patterns of sacral fractures. J Neurosurg. 1990;72(6):889–893. 10.3171/jns.1990.72.6.0889
  5. 5.
    ↵
    Nakamichi K , Watanabe H , Kataoka T , et al . Lumbao-sacral fixation by low profile S1-iliac trajectory(LSIT). J Spine Res. 2013;4(10):1505–1508.
  6. 6.
    ↵
    Lee SH , Chung CK , Yoon DH , An SB , Han IB , Sohn S . Percutaneous modified iliac screw fixation: technique and clinical experience. Acta Neurochir. 2026;168(1):20. 10.1007/s00701-026-06778-7
  7. 7.
    ↵
    Altwaijri NA , Abdulaziz M , Bhat R , Ellafi A , Alhabdan KA . Spinopelvic dissociation case report and literature review. Cureus. 2023;15(5):e39750. 10.7759/cureus.39750
  8. 8.
    ↵
    Nork SE , Jones CB , Harding SP , Mirza SK , Routt ML . Percutaneous stabilization of U-shaped sacral fractures using iliosacral screws: technique and early results. J Orthop Trauma. 2001;15(4):238–246. 10.1097/00005131-200105000-00002
  9. 9.
    ↵
    Saiz AM , Kellam PJ , Amin A , et al . Percutaneous sacral screw fixation alone sufficient for mildly displaced U-type sacral fractures with preserved osseous fixation pathways. Eur J Orthop Surg Traumatol. 2024;34(7):3523–3527. 10.1007/s00590-023-03661-4
  10. 10.
    ↵
    Elmoghany ME , Gharbo NO , Ayoub MA , Farouk OA , Mashal H-D . Fixation of unstable sacral fractures by transpedicular system: a prospective study. Int Orthop. 2026;50(1):219–228. 10.1007/s00264-025-06673-3
  11. 11.
    ↵
    Martinez Rivera A , Bentz GP , Stone DH , et al . Sacral U-type fractures: a comparative study of treatment approaches. Global Spine J. 2026;2026:21925682261422685. 10.1177/21925682261422685
  12. 12.
    ↵
    König MA , Jehan S , Boszczyk AA , Boszczyk BM . Surgical management of U-shaped sacral fractures: a systematic review of current treatment strategies. Eur Spine J. 2012;21(5):829–836. 10.1007/s00586-011-2125-7
  13. 13.
    ↵
    Griffin DR , Starr AJ , Reinert CM , Jones AL , Whitlock S . Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure? J Orthop Trauma. 2003;17(6):399–405. 10.1097/00005131-200307000-00001
  14. 14.
    ↵
    Godolias P , Plümer J , Cibura C , Dudda M , Schildhauer TA , Chapman JR . Posterior pelvic ring injuries, lumbosacral junction instabilities and stabilization techniques for spinopelvic dissociation: a narrative review. Arch Orthop Trauma Surg. 2024;144(4):1627–1635. 10.1007/s00402-024-05211-x
  15. 15.
    ↵
    Schildhauer TA , Bellabarba C , Nork SE , Barei DP , Routt MLC , Chapman JR . Decompression and lumbopelvic fixation for sacral fracture-dislocations with spino-pelvic dissociation. J Orthop Trauma. 2006;20(7):447–457. 10.1097/00005131-200608000-00001
  16. 16.
    ↵
    Hirschfeld M , Pascual-López FJ , Guerado E . Spinopelvic dissociation: current concepts. Rev Esp Cir Ortop Traumatol. 2024;68(4):398–408. 10.1016/j.recot.2023.09.001
  17. 17.
    ↵
    Schildhauer TA , Ledoux WR , Chapman JR , Henley MB , Tencer AF , Routt MLC . Triangular osteosynthesis and iliosacral screw fixation for unstable sacral fractures: a cadaveric and biomechanical evaluation under cyclic loads. J Orthop Trauma. 2003;17(1):22–31. 10.1097/00005131-200301000-00004
  18. 18.
    ↵
    Jones CB , Sietsema DL , Hoffmann MF . Can lumbopelvic fixation salvage unstable complex sacral fractures? Clin Orthop Relat Res. 2012;470(8):2132–2141. 10.1007/s11999-012-2273-z
  19. 19.
    ↵
    Koshimune K , Ito Y , Sugimoto Y , et al . Minimally invasive spinopelvic fixation for unstable bilateral sacral fractures. Clin Spine Surg. 2016;29(3):124–127. 10.1097/BSD.0000000000000090
  20. 20.
    ↵
    Williams SK , Quinnan SM . Percutaneous lumbopelvic fixation for reduction and stabilization of sacral fractures with spinopelvic dissociation patterns. J Orthop Trauma. 2016;30(9):e318–e324. 10.1097/BOT.0000000000000559
  21. 21.
    ↵
    Liu Z-J , Hu Y-C , Tian W , et al . Robot-aided minimally invasive lumbopelvic fixation in treatment of traumatic spinopelvic dissociation. Orthop Surg. 2021;13(2):563–572. 10.1111/os.12908
  22. 22.
    ↵
    Pearson JM , Niemeier TE , McGwin G , Rajaram Manoharan S . Spinopelvic dissociation: comparison of outcomes of percutaneous versus open fixation strategies. Adv Orthop. 2018;2018:5023908. 10.1155/2018/5023908
  23. 23.
    ↵
    Okuda A , Maegawa N , Matsumori H , et al . Minimally invasive spinopelvic “crab-shaped fixation” for unstable pelvic ring fractures: technical note and 16 case series. J Orthop Surg Res. 2019;14(1):51. 10.1186/s13018-019-1093-1
  24. 24.
    ↵
    Fujino S , Miyagi M , Tajima S , et al . Surgical treatment for suicidal jumper’s fracture (unstable sacral fracture) with thoracolumbar burst fracture: a report of three cases. Spine Surg Relat Res. 2017;1(2):100–106. 10.22603/ssrr.1.2016-0026
  25. 25.
    ↵
    Girgis MY , Tang A , Pheasant MS , Koury KL , Jung MT , Chen T . Minimally invasive and navigation-assisted fracture stabilization following traumatic spinopelvic dissociation. J Clin Med. 2025;14(4):1289. 10.3390/jcm14041289
  26. 26.
    ↵
    Kanezaki S , Miyazaki M , Notani N , et al . Minimally invasive triangular osteosynthesis for highly unstable sacral fractures: technical notes and preliminary clinical outcomes. Medicine. 2019;98(24):e16004. 10.1097/MD.0000000000016004
View Abstract