Immunobiology of periprosthetic inflammation and pain following ultra-high-molecular-weight-polyethylene wear debris in the lumbar spine

JH Werner, JH Rosenberg, KL Keeley… - Expert review of …, 2018 - Taylor & Francis
Introduction: Wear debris-induced osteolysis is a common cause of arthroplasty failure in
several joints including the knee, hip and intervertebral disc. Debris from the prosthesis can …

ProDisc cervical arthroplasty does not alter facet joint contact pressure during lateral bending or axial torsion

NV Jaumard, JA Bauman, BB Guarino, AJ Gokhale… - Spine, 2013 - journals.lww.com
Study Design. A biomechanical study of facet joint pressure after total disc replacement
using cadaveric human cervical spines during lateral bending and axial torsion. Objective …

ISASS policy statement–lumbar artificial disc

J Zigler, R Garcia - International Journal of Spine Surgery, 2015 - ijssurgery.com
Purpose The primary goal of this Policy Statement is to educate patients, physicians,
medical providers, reviewers, adjustors, case managers, insurers, and all others involved or …

[HTML][HTML] ICR in human cadaveric SPECIMENS: an essential parameter to consider in a new lumbar disc prosthesis DESIGN

A Vanaclocha-Saiz, CM Atienza, V Vanaclocha… - North American Spine …, 2020 - Elsevier
Study design Biomechanical study in cadaveric specimens. Background The commercially
available lumbar disc prostheses do not reproduce the intact disc's Instantaneous centre of …

Effect of total lumbar disc replacement on the treatment of discogenic low lumbar pain: preliminary outcomes

Z Li, H Xiao, M Sai, T Wei - Chinese Medical Journal, 2013 - journals.lww.com
Background Lumbar pedicle screw fixation and fusion are major procedures for treating
discogenic low back pain (DLBP). However, due to its advantages of preserving the …

[BOOK][B] Neuromodulation in der Schmerztherapie: Epidurale und subkutane Nervenstimulation-Intrathekale Medikamentengabe

M Kugler - 2013 - books.google.com
-verständlich: Wirkungsweise und technisches Vorgehen bei allen neuromodulierenden
Verfahren in Ergänzung zur konservativen Schmerztherapie-praxisrelevant: klare …

[PDF][PDF] North American Spine Society Journal (NASSJ)

A Vanaclocha-Saiz, CM Atienza, V Vanaclocha… - roderic.uv.es
abstract Study design: Biomechanical study in cadaveric specimens. Background: The
commercially available lumbar disc prostheses do not reproduce the intact disc's …

Élaboration par méthode Delphi d'un questionnaire pour le dépistage d'une souffrance facettaire avant pose de prothèse discale lombaire

JE Loret, JM Berthelot, E Lioret, J Delecrin - Revue du Rhumatisme, 2016 - Elsevier
Résumé Rationnel Près de 20% des patients traités par prothèse discale lombaire
présentent des lombalgies facettaires. Méthodes Les signes cliniques qui paraissaient les …

[CITATION][C] FACULTE DE MEDECINE DE TOURS

B Julien - 2012 - Université François-Rabelais