Introduction

The aim of this systematic review and meta-analysis was to evaluate the best currently available evidence from randomized controlled trials comparing pulsed electromagnetic fields (PEMF) or low-intensity pulsed ultrasound (LIPUS) bone growth stimulation with placebo for acute fractures.

Materials and methods

We performed a systematic literature search of the medical literature from 1980 to 2013 for randomized clinical trials concerning acute fractures in adults treated with PEMF or LIPUS. Two reviewers independently determined the strength of the included studies by assessing the risk of bias according to the criteria in the Cochrane Handbook for Systematic Reviews of Interventions.

Results

Seven hundred and thirty-seven patients from 13 trials were included. Pooled results from 13 trials reporting proportion of nonunion showed no significant difference between PEMF or LIPUS and control. With regard to time to radiological union, we found heterogeneous results that significantly favoured PEMF or LIPUS bone growth stimulation only in non-operatively treated fractures or fractures of the upper limb. Furthermore, we found significant results that suggest that the use of PEMF or LIPUS in acute diaphyseal fractures may accelerate the time to clinical union.

Conclusions

Current evidence from randomized trials is insufficient to conclude a benefit of PEMF or LIPUS bone growth stimulation in reducing the incidence of nonunions when used for treatment in acute fractures. However, our systematic review and meta-analysis suggest that PEMF or LIPUS can be beneficial in the treatment of acute fractures regarding time to radiological and clinical union. PEMF and LIPUS significantly shorten time to radiological union for acute fractures undergoing non-operative treatment and acute fractures of the upper limb. Furthermore, PEMF or LIPUS bone growth stimulation accelerates the time to clinical union for acute diaphyseal fractures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. van der Molen AB, Groothoff JW, Visser GJ, Robinson PH, Eisma WH (1999) Time off work due to scaphoid fractures and other carpal injuries in The Netherlands in the period 1990 to 1993. J Hand Surg 24(2):193–198

    Article  Google Scholar 

  2. Bonafede M, Espindle D, Bower AG (2013) The direct and indirect costs of long bone fractures in a working age US population. J Med Econ 16(1):169–178

    Article  PubMed  Google Scholar 

  3. Griffin XL, Costello I, Costa ML (2008) The role of low intensity pulsed ultrasound therapy in the management of acute fractures: a systematic review. J Trauma 65(6):1446–1452

    Article  PubMed  Google Scholar 

  4. Walker NA, Denegar CR, Preische J (2007) Low-intensity pulsed ultrasound and pulsed electromagnetic field in the treatment of tibial fractures: a systematic review. J Athl Train 42(4):530–535

    PubMed Central  PubMed  Google Scholar 

  5. Moher D, Liberati A, Tetzlaff J, Altman DG, Group P (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. BMJ 339:b2535

    Article  PubMed Central  PubMed  Google Scholar 

  6. Higgins J, Altman DG (2008) Assessing risk of bias in included studies. In: Cochrane Handbook for Systematic Reviews of Interventions: Cochrane Book Series. Wiley, pp 187–241

  7. Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174

    Article  CAS  PubMed  Google Scholar 

  8. Higgins JP, Thompson SG (2002) Quantifying heterogeneity in a meta-analysis. Stat Med 21(11):1539–1558

    Article  PubMed  Google Scholar 

  9. Heckman JD, Ryaby JP, McCabe J, Frey JJ, Kilcoyne RF (1994) Acceleration of tibial fracture-healing by non-invasive, low-intensity pulsed ultrasound. J Bone Joint Surg Am Vol 76(1):26–34

    CAS  Google Scholar 

  10. Kristiansen TK, Ryaby JP, McCabe J, Frey JJ, Roe LR (1997) Accelerated healing of distal radial fractures with the use of specific, low-intensity ultrasound. A multicenter, prospective, randomized, double-blind, placebo-controlled study. J Bone Joint Surg Am Vol 79(7):961–973

    CAS  Google Scholar 

  11. Emami A, Petren-Mallmin M, Larsson S (1999) No effect of low-intensity ultrasound on healing time of intramedullary fixed tibial fractures. J Orthop Trauma 13(4):252–257

    Article  CAS  PubMed  Google Scholar 

  12. Mayr E, Rudzki MM, Rudzki M, Borchardt B, Hausser H, Ruter A (2000) Does low intensity, pulsed ultrasound speed healing of scaphoid fractures? Handchir Mikrochir Plast Chir 32(2):115–122

    Article  CAS  PubMed  Google Scholar 

  13. Leung KS, Lee WS, Tsui HF, Liu PP, Cheung WH (2004) Complex tibial fracture outcomes following treatment with low-intensity pulsed ultrasound. Ultrasound Med Biol 30(3):389–395

    Article  PubMed  Google Scholar 

  14. Handolin L, Kiljunen V, Arnala I, Kiuru MJ, Pajarinen J, Partio EK et al (2005) No long-term effects of ultrasound therapy on bioabsorbable screw-fixed lateral malleolar fracture. Scand J Surg 94(3):239–242

    CAS  PubMed  Google Scholar 

  15. Handolin L, Kiljunen V, Arnala I, Kiuru MJ, Pajarinen J, Partio EK et al (2005) Effect of ultrasound therapy on bone healing of lateral malleolar fractures of the ankle joint fixed with bioabsorbable screws. J Orthop Sci 10(4):391–395

    Article  PubMed  Google Scholar 

  16. Handolin L, Kiljunen V, Arnala I, Pajarinen J, Partio EK, Rokkanen P (2005) The effect of low intensity ultrasound and bioabsorbable self-reinforced poly-l-lactide screw fixation on bone in lateral malleolar fractures. Arch Orthop Trauma Surg 125(5):317–321

    Article  PubMed  Google Scholar 

  17. Lubbert PH, van der Rijt RH, Hoorntje LE, van der Werken C (2008) Low-intensity pulsed ultrasound (LIPUS) in fresh clavicle fractures: a multi-centre double blind randomised controlled trial. Injury 39(12):1444–1452

    Article  PubMed  Google Scholar 

  18. Rue JP, Armstrong DW 3rd, Frassica FJ, Deafenbaugh M, Wilckens JH (2004) The effect of pulsed ultrasound in the treatment of tibial stress fractures. Orthopedics 27(11):1192–1195

    PubMed  Google Scholar 

  19. Faldini C, Cadossi M, Deianira L, Betti E, Chiarello E, Giannini S (2010) Electromagnetic bone growth stimulation in patients with femoral neck fractures treated with screws: prospective randomized double-blind study. Curr Orthop Pract 21(3):282–287

    Article  Google Scholar 

  20. Adie S, Harris IA, Naylor JM, Rae H, Dao A, Yong S et al (2011) Pulsed electromagnetic field stimulation for acute tibial shaft fractures: a multicenter, double-blind, randomized trial. J Bone Joint Surg Am Vol 93(17):1569–1576

    Article  Google Scholar 

  21. Hannemann PF, Gottgens KW, van Wely BJ, Kolkman KA, Werre AJ, Poeze M et al (2012) The clinical and radiological outcome of pulsed electromagnetic field treatment for acute scaphoid fractures: a randomised double-blind placebo-controlled multicentre trial. J Bone Joint Surg Br Vol 94(10):1403–1408

    Article  CAS  Google Scholar 

  22. Ardan NI Jr, Janes JM, Herrick JF (1954) Changes in bone after exposure to ultrasonic energy. Minn Med 37(6):415–420

    PubMed  Google Scholar 

  23. Borsalino G, Bagnacani M, Bettati E, Fornaciari F, Rocchi R, Uluhogian S et al (1988) Electrical stimulation of human femoral intertrochanteric osteotomies. Double-blind study. Clin Orthop Relat Res 237:256–263

    PubMed  Google Scholar 

  24. Azuma Y, Ito M, Harada Y, Takagi H, Ohta T, Jingushi S (2001) Low-intensity pulsed ultrasound accelerates rat femoral fracture healing by acting on the various cellular reactions in the fracture callus. J Bone Miner Res 16(4):671–680

    Article  CAS  PubMed  Google Scholar 

  25. Sharrard WJ (1990) A double-blind trial of pulsed electromagnetic fields for delayed union of tibial fractures. J Bone Joint Surg Br Vol 72(3):347–355

    CAS  Google Scholar 

  26. Bassett CA, Mitchell SN, Gaston SR (1981) Treatment of ununited tibial diaphyseal fractures with pulsing electromagnetic fields. J Bone Joint Surg Br Vol 63(4):511–523

    CAS  Google Scholar 

  27. Nolte PA, van der Krans A, Patka P, Janssen IM, Ryaby JP, Albers GH (2001) Low-intensity pulsed ultrasound in the treatment of nonunions. J Trauma 51(4):693–702 discussion-3

    Article  CAS  PubMed  Google Scholar 

  28. Schofer MD, Block JE, Aigner J, Schmelz A (2010) Improved healing response in delayed unions of the tibia with low-intensity pulsed ultrasound: results of a randomized sham-controlled trial. BMC Musculoskelet Disord 11:229

    Article  PubMed Central  PubMed  Google Scholar 

  29. Bashardoust Tajali S, Houghton P, MacDermid JC, Grewal R (2012) Effects of low-intensity pulsed ultrasound therapy on fracture healing: a systematic review and meta-analysis. Am J Phys Med Rehabilitation Assoc Acad Physiatr 91(4):349–367

    Article  Google Scholar 

  30. Poolman RW, Abouali JA, Conter HJ, Bhandari M (2007) Overlapping systematic reviews of anterior cruciate ligament reconstruction comparing hamstring autograft with bone-patellar tendon-bone autograft: why are they different? J Bone Joint Surg Am Vol 89(7):1542–1552

    Article  Google Scholar 

  31. Bhandari M, Fong K, Sprague S, Williams D, Petrisor B (2012) Variability in the definition and perceived causes of delayed unions and nonunions: a cross-sectional, multinational survey of orthopaedic surgeons. J Bone Joint Surg Am Vol 94(15):e1091–e1096

    Article  Google Scholar 

  32. Corrales LA, Morshed S, Bhandari M, Miclau T 3rd (2008) Variability in the assessment of fracture-healing in orthopaedic trauma studies. J Bone Joint Surg Am Vol 90(9):1862–1868

    Article  Google Scholar 

  33. Button ML, Sprague S, Gharsaa O, Latouche S, Bhandari M (2009) Economic evaluation of bone stimulation modalities: a systematic review of the literature. Indian J Orthop 43(2):168–174

    Article  PubMed Central  PubMed  Google Scholar 

Download references

Acknowledgments

Financial support for this study was received from the Netherlands Organisation for Health Research and Development (ZonMw, reference 171001004).

Conflict of interest

All named authors declare that they have no conflicts of interest to disclose. All named authors declare that they have no financial relationship with any organization that contributed to this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. F. W. Hannemann.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hannemann, P.F.W., Mommers, E.H.H., Schots, J.P.M. et al. The effects of low-intensity pulsed ultrasound and pulsed electromagnetic fields bone growth stimulation in acute fractures: a systematic review and meta-analysis of randomized controlled trials. Arch Orthop Trauma Surg 134, 1093–1106 (2014). https://doi.org/10.1007/s00402-014-2014-8

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00402-014-2014-8

Keywords

Navigation