Segmental pedicle screw fixation is rapidly becoming a popular method of spinal instrumentation. Few studies have investigated the rates of adjacent superior segment facet joint violation. The purpose of our study were to investigate the incidence of superior segment facet joint violation after pedicle screw instrumentation in the lumbar spine and to evaluate technical factors related to the incidence. A prospective study including 96 patients who underwent lumbar and lumbosacral fusion was conducted between March 2006 and December 2007. All patients had bilateral or unilateral posterior pedicle screw-rod instrumentation with either CD-Horizon (top-loading screw) or TSRH (side-connecting screw) implants. Pedicle screws were instrumented according to the methods advocated by Roy-Camille (Group 1, 20 cases) or Weinstein (Group 2, 76 cases). All patients had computed tomography scan at 1 week post operation. CT scans were reviewed blind by an experienced spine research fellow and a consultant radiologist to determine violation of the adjacent superior segment facet joint. Superior segment facet joint violation occurred in all of the 20 patients (100%) and all of the top-level screws (100%) in Group 1. The spinal research fellow noted the incidence of facet joint violation to be present in 23.8% of the screws and 32.9% of the patients in Group 2, whereas the consultant radiologist noted this to be the case in 25.2 and 35.5%, respectively. The incidence of facet joint violation in patients with CD-Horizon screws was far lower than patients with TSRH screws (< 0.001). In conclusion, it seems that meticulous surgical dissection without injuring the top-level facet joints, proper instrumentation of pedicle screws with the appropriate entry site (Weinstein’s method), trajectory, and use of top-loading screw heads are some ways that surgeons could minimize the risk of top-level facet joint violation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Aota Y, Kumano K, Hirabayashi S (1995) Postfusion instability at the adjacent segments after rigid pedicle screw fixation for degenerative lumbar spinal disorders. J Spinal Disord 8:464–473. doi:10.1097/00002517-199512000-00008

    Article  PubMed  CAS  Google Scholar 

  2. Davne SH, Myers DL (1992) Complications of lumbar spinal fusion with transpedicular instrumentation. Spine 17(suppl):184–189. doi:10.1097/00007632-199206001-00021

    Article  Google Scholar 

  3. Glaser J, Stanley M, Sayre H et al (2003) A 10-year follow-up evaluation of lumbar spine fusion with pedicle screw fixation. Spine 28:1390–1395. doi:10.1097/00007632-200307010-00008

    Article  PubMed  Google Scholar 

  4. Guigui P, Wodecki P, Bizot P et al (2000) Long term influence of associated arthrodesis on adjacent segments in the treatment of lumbar stenosis: a series of 127 cases with 9-year follow-up. Rev Chir Orthop Repar Appar Mot 86:546–557

    CAS  Google Scholar 

  5. Hambly MF, Wiltse LL, Raghavan N et al (1998) The transition zone above a lumbosacral fusion. Spine 23:1785–1792. doi:10.1097/00007632-199808150-00012

    Article  PubMed  CAS  Google Scholar 

  6. Krag MH (1991) Biomechanics of the thoracolumbar spinal fixation: a review. Spine 16:S84–S99. doi:10.1097/00007632-199103001-00014

    Article  PubMed  CAS  Google Scholar 

  7. Lonstein JE, Denis F, Perra JH et al (1999) Complications associated with pedicle screws. J Bone Joint Surg Am 81:1519–1528

    PubMed  CAS  Google Scholar 

  8. Lorenz M, Patwardhan A, Vanderby R (1983) Load-bearing characteristics of lumbar facets in normal and surgically altered spinal segments. Spine 8:122–130. doi:10.1097/00007632-198303000-00002

    Article  PubMed  CAS  Google Scholar 

  9. Miyakoshi N, Abe E, Shimada Y et al (2000) Outcome of one-level posterior lumbar interbody fusion for spondylolisthesis and postoperative intervertebral disc degeneration adjacent to the fusion. Spine 25:1837–1842. doi:10.1097/00007632-200007150-00016

    Article  PubMed  CAS  Google Scholar 

  10. Moshirfar A, Jenis LG, Spector LR et al (2006) Computed tomography evaluation of superior-segment facet-joint violation after pedicle instrumentation of the lumbar spine with a midline surgical approach. Spine 31:2624–2629. doi:10.1097/01.brs.0000240691.35707.e8

    Article  PubMed  Google Scholar 

  11. Roy-Camille R, Saillant G, Mazel C (1986) Internal fixation of the lumbar spine with pedicle screw plating. Clin Orthop Relat Res 203:7–17

    PubMed  Google Scholar 

  12. Roy-Camille R, Saillant G, Mazel C (1986) Plating of thoracic, thoracolumbar, and lumbar injuries with pedicle screw plates. Orthop Clin North Am 17:147–159

    PubMed  CAS  Google Scholar 

  13. Shah RR, Mohammed S, Saifuddin A et al (2003) Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine. Spine 28:272–275. doi:10.1097/00007632-200302010-00013

    Article  PubMed  Google Scholar 

  14. Weinstein JN, Spratt KF, Spengler D et al (1988) Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement. Spine 13:1012–1018. doi:10.1097/00007632-198809000-00008

    Article  PubMed  CAS  Google Scholar 

  15. Wiltse LL, Radecki SE, Biel HM et al (1999) Comparative study of the incidence and severity of degenerative change in the transition zones after instrumented versus noninstrumented fusions of the lumbar spine. J Spinal Disord 12:27–33. doi:10.1097/000002517-199902000-00004

    Article  PubMed  CAS  Google Scholar 

  16. Yahiro MA (1994) Comprehensive literature review: pedicle screw fixation devices. Spine 19(suppl):2274–2278

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jie Zhao.

Additional information

No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this manuscript.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chen, Z., Zhao, J., Xu, H. et al. Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine. Eur Spine J 17, 1476–1480 (2008). https://doi.org/10.1007/s00586-008-0776-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-008-0776-9

Keywords

Navigation