Introduction

Anterior cervical discectomy and fusion (ACDF) is a common treatment for a cervical radicular syndrome producing persistent arm pain with or without neck pain. The choices for anterior cervical fusion are many, and a recent literature review has described the lack of clarity on the best procedure options for ACDF [1]. To maintain or enlarge the disc space height and maintain lordosis a block of autograft is frequently inserted into the disc space [2, 3]. However, graft harvest for cervical interbody fusion can be associated with pain at the iliac crest harvest site [1].

Interbody fusion cages made of metal, plastic and most recently ceramic materials have been shown to have advantages over autograft bone blocks: (1) using a cage provides strength to support a larger axial load than bone; (2) the cage can be filled with locally harvested autograft (from osteophytes) or bone graft substitutes, eliminating the need for harvest from the iliac crest, and finally, (3) using a cage saves time in the procedure, reduces blood loss and reduces post-operative pain compared with obtaining graft from the iliac crest.

Despite a paucity of data supporting choice of cage materials [4], plastic cages made from polyetheretherketone (PEEK) have become a popular method for stabilizing the disc space after ACDF [58]. PEEK as a biomaterial has some attractive properties and some liabilities [9]. It has a modulus of elasticity similar to bone. PEEK is hydrophobic and develops a mild fibrous tissue reaction around implants. While it is radiolucent and causes no distortion of X-ray, CT or MR images, the lucency makes it difficult to evaluate cage position and fusion. This problem is partially overcome by inserting radiopaque metal markers into PEEK cages.

In order to address the deficiencies of autograft blocks, implant manufacturers have evaluated additional materials including ceramics. Ceramic materials are attractive because they are generally biocompatible and have desirable imaging properties. The toughest and most stable ceramic is silicon nitride (Si3N4). Silicon nitride cages have been tested extensively in cadavers, demonstrating desirable imaging characteristics [10], and in animals demonstrating biocompatibility and bacteriostatic properties [11, 12]. Amedica Corporation (Salt Lake City, UT, USA) has designed spacers made from an outer shell of dense silicon nitride and a center filled with a microporous form of the same material (Valeo CCsC silicon nitride spacers) (Fig. 1). In a sheep model, these spacers demonstrated robust bone ingrowth resulting in fusion [13].

Fig. 1
figure 1

Valeo CCsC silicon nitride cervical interbody fusion device used in the CASCADE trial with radiographic characteristics

Because PEEK cages have become the gold standard for cervical interbody fusion, the CAncellous Structure Ceramic Arthrodesis DEvice (CASCADE) trial was designed to compare stand-alone silicon nitride spacers filled with microporous silicon nitride to PEEK cages filled with autograft harvested from osteophytes. This article reports the clinical and radiological outcome of patients treated with silicon nitride versus PEEK and is the first paper of human outcomes using silicon nitride cages.

Materials and methods

The study protocol has been published in detail previously [14] and a summary is available on the clinicaltrials.gov website (ClinicalTrials.gov Identifier: NCT01511445). The trial is also registered in the Netherlands (NL 36013.098.11). Briefly, the study was designed as a prospective, single-blind randomized controlled comparison of single-level ACDF using Valeo CCsC silicon nitride spacers versus PEEK cages. Initial analysis was performed when all patients reached 1 year follow-up, and final analysis was conducted when all patients had 2 years follow-up. The study was approved by the Medical Ethics Committee of Southwest Holland. Informed consent was obtained from all individual participants included in the study. The patients were treated by two neurosurgeons of Haaglanden Medical Center, The Hague, Netherlands (MA and JW).

The inclusion and exclusion criteria are similar to other ACDF randomized trials using PEEK cages as control groups [15, 16] (Table 1). Patients were included if they presented with radicular symptoms in one or both arms indicating a single nerve root involvement with or without medullary symptoms and with or without neck pain. The diagnosis of a herniation with or without osteophytes at a single level was confirmed radiographically. Exclusion criteria included previous cervical surgery, severe kyphosis at the involved level, neck pain only without radicular or medullary symptoms, metabolic disease, neoplasms, cervical trauma, spinal anomalies, severe mental or psychiatric disease, and inadequate Dutch language.

Table 1 Inclusion and exclusion criteria

Randomization (1:1 ratio of silicon nitride spacers to PEEK cages) was carried out in the operating room after anesthesia was induced by opening sequentially numbered, sealed envelopes that were prepared by the data manager. The randomization order was determined using a random number generator to produce random blocks of four, six and eight numbers. Patients were blinded to the group allocation during the first year of follow-up.

Surgical procedure

A standard right-side approach was made after confirming the level on fluoroscopy. A standard anterior discectomy was performed with the aid of loupe magnification or operating microscope, depending on the preference of the surgeon. After complete decompression, the allocated spacer or cage was implanted. Silicon nitride spacers (Amedica Corporation, Salt Lake City, UT, USA) were wetted with patient blood from the operative field but had no other filler. PEEK cages (Medicrea Manta, Lyon, France) were filled with local autograft obtained from osteophytes at the operative level. No patients had autograft or any other substance placed outside the spacers or cages, and no patients had supplemental fixation such as plates and screws. The spacers and cage sizes were chosen to incorporate the largest possible footprint; the typical cage was 17 mm wide by 14 mm in depth. The silicon nitride implants had parallel superior and inferior surfaces, while the PEEK cages had 3° of lordosis. After surgery, all patients were mobilized as soon as possible without a collar.

Primary non-inferiority hypothesis

The primary effectiveness hypothesis, as stated in the Clinical Trial Protocol, is that there is no difference in Neck Disability Index (NDI) improvement between the two study arms. This hypothesis was formulated for testing clinical non-inferiority based on the Blackwelder approach [17]. In the Blackwelder approach, the null hypothesis is that the investigational device is clinically significantly worse than control by an amount (at least) equal to an a priori selected non-inferiority margin. The minimal clinically important difference (MCID) for the NDI is 7.5 points out of 50, or 15% when the scale is standardized to a range from 0 to 100 [18]. Therefore, the primary null hypothesis is that the mean improvement for the investigational device is smaller (i.e., less negative) than the mean improvement for the control device by an amount equal to or exceeding 15 out of the 100-point scale.

Sample size determination

The sample size was calculated with 90% power to detect a difference in NDI improvement equal to the MCID of 15%, the non-inferiority margin. The sample size calculation used the improvement amount and standard deviation observed in a previous study of carbon fiber-reinforced PEEK cages [19]. The calculated sample size was 46 patients in each group, and an additional 4 patients were added to each group to allow 8% for loss to follow-up.

Outcome measures

The primary outcome measure is improvement in the NDI which has been translated into Dutch and validated for the population of the Netherlands [20, 21]. Secondary outcome measures were the 100-mm visual analog scale (VAS) for arm pain and neck pain [22], the 7-point Likert self-rating scale for perceived recovery in which “complete recovery” and “almost complete recovery” are defined as good outcome [23], and the generic health survey on the Short Form-36 (SF-36) [24, 25]. Adverse events, reoperations, and surgical complications were also recorded.

Radiological assessment

At each follow-up time point, four plane films were collected (standing anterior–posterior, lateral, flexion and extension radiographs). A thin-slice CT scan was also collected at the 6 months follow-up. In addition, quantitative and qualitative motion analysis using Medical Metrics, Inc. (MMI, Houston, TX, USA) software [26] allowed measurement of rotation on flexion–extension films with an accuracy of ±1°. Images for each follow-up time point were provided on compact disks for analysis by MMI. Fusion for this study was defined as rotation ≤4° and ≤1.25 mm translation on flexion–extension films. The dynamic X-ray and CT at 6 months follow-up were also used to measure cage migration and subsidence. Radiologists quantified bone bridging around implants, bone bridging through the PEEK cage and lucencies around both types of implant.

Statistical analysis

The statistical analysis plan was modified from the published protocol to meet FDA recommendations for a prospective study prior to the completion of data collection. Pre-operative data were analyzed for all randomized patients. The Fisher’s exact test (two-sided) was used for categorical variables, while the Wilcoxon rank sum test was used for continuous variables. Missing values in the non-inferiority analysis were conservatively filled using the last value carried forward method.

Results

Between December 2011 and October 2013, 104 of 390 eligible patients were enrolled in the randomized trial. Four patients were censored because of protocol violations (surgery by non-investigators). All presented data are performed on the intention-to-treat analysis of 100 patients. The complete study patient accountability flowchart is presented in Fig. 2. Fifty-two patients were randomized for silicon nitride and 48 patients for PEEK. Baseline characteristics for both groups were similar (Table 2). The only statistical difference was seen in the level of treatment with significantly more patients in the silicone nitrate group having surgeries in the lower cervical spine C6C7 and C7T1. Over 40% of the study subjects were smokers. There were no crossovers or allocation errors. At 24 months follow-up, data from 96 patients were available.

Fig. 2
figure 2

Neck and Disability Index scores during follow-up of 24 months. At 3 and 12 months there were small significant differences in favor of PEEK, although not clinically relevant

Table 2 Baseline demographics of 100 analyzed patients (4 were excluded because of protocol violation)

Clinical outcome

Primary outcome measure

Patients in both study arms showed large improvements in NDI scores during the 24-month follow-up. Patients treated with PEEK had significantly better improvement at 3 months and 12 months, although these differences were less than the MCID for the NDI of 7.5 points. There was no significant difference in NDI score at 2 years (Fig. 2).

Other outcome measures

VAS arm pain and VAS neck pain improved in both groups, although there was a significant difference in arm pain at 12 months and neck pain at 3 months, both favoring PEEK. These differences did not reach the MCID of 20 mm and were therefore not clinically relevant. Of all SF-36 domains, only Bodily Pain at 3 months follow-up had a statistically significant difference, favoring PEEK patients. The patients’ reported perceived recovery improved during the follow-up moments; 78% of the silicon nitride patients and 88% of the PEEK patients reported good outcome at 24 months (p > 0.05). All secondary outcome measures are illustrated in Table 3.

Table 3 Treatment effect of primary and secondary outcome during follow-up period

Complications and re-operations

The surgical procedures and hospital stay were uneventful for almost all patients (Table 4). There was no difference in operative time, estimated blood loss, or length of stay between the two groups. Two PEEK patients and one silicon nitride patient had incidental durotomies which were repaired intra-operatively and had no permanent sequelae. Nine silicon nitride and eight PEEK patients had transient dysphagia, with or without hoarseness. One patient in each group had recurrent symptomatic nerve root compression at the index level because of substantial subsidence. In both cases, the device was replaced by an allograft block and the patient had supplemental fixation with a plate and screws. One silicon nitride patient had a deep wound infection requiring debridement without spacer removal and the patient was treated with antibiotics. During the follow-up period of 2 years, nine patients had revision surgery at the adjacent level whereby disc herniations or osteophytes were removed; six in the silicon nitride group and three patients in the PEEK group. The average time from the index surgery to the secondary adjacent level surgery was 12.6 months for silicon nitride patients and 11.3 months for PEEK cage patients.

Table 4 Operative characteristics with complications

Fusion and subsidence

Based on the MMI analysis of flexion/extension motion ≤4°, there was no significant difference in fusion rate between silicon nitride and PEEK. In both groups the fusion rate increased over time and improved from 66% at 3 months follow-up, to 90% at 24 months follow-up for both groups (Fig. 3). At 6 months follow-up, 26 patients treated with silicon nitride and 27 patients treated with PEEK showed some degree of subsidence at flexion/extension images and CT. The mean subsidence was 1.48 mm for silicon nitride and 1.59 mm for PEEK, and the difference was not statistically significantly different (Table 5).

Fig. 3
figure 3

Fusion rate defined as rotation ≤4° and ≤1.25 mm translation on flexion–extension films on dynamic X-ray. In both groups the fusion rate increased over time and there was no significant difference between both groups

Table 5 Subsidence measured on CT and X-ray at 6 months follow-up

Discussion

The CASCADE trial was designed to compare microporous silicon nitride as a spacer material versus the gold standard of PEEK filled with autograft. It was modeled after ongoing trials comparing anterior discectomy with ACDF and decompression plus cervical artificial discs [15, 16]. In those trials, the ACDF procedure used PEEK cages filled with a beta tricalcium phosphate synthetic graft material. The use of local autograft in the CASCADE trial raises the threshold for non-inferiority because autograft produces have a higher fusion rate [27]. Based on the CASCADE trial, patients treated with silicon nitride and patients treated with PEEK cages reported similar recovery rates and improvement in NDI during follow-up with similar fusion rates. However, some intermediate results were in favor of PEEK, but these differences did not reach the level of the minimal clinically important difference and therefore had no clinical relevance.

The main source of pain relief in the procedure of anterior cervical discectomy is decompression of the nerve root by removing the herniated disc and/or osteophytes. Numerous studies on ACDF have demonstrated satisfactory clinical and radiological results in the majority of patients [1, 8, 2830]. Even in the older population ACDF surgery will result in a significant gain in health-state utility [31]. Adding an interbody implant to the anterior discectomy procedure is primarily to stabilize the height and angulation of the disc space. Loss of height could lead to recurrent stenosis of the foramen and recurrence of radicular pain. Even empty cages are associated with improvement in pain and disability and remarkable high fusion rates are documented [29, 32].

A recently published randomized controlled trial on acrylic cages versus PEEK cages documented significant clinical and radiological improvement in favor of acrylic cages [28]. The study suggests more cost effectiveness of acrylic implants compared to PEEK, although it is limited by small patient numbers and short-term follow-up. Therefore, in our opinion, the development of new implant technologies is better understood as long as the ultimate and optimal implant has not been defined yet.

In our trial, patients reported similar recovery rates during follow-up regardless of the type of implant. With composite clinical success defined as at least 15-point improvement of NDI (out of 100), fusion determined on dynamic X-rays, and no revision surgery at the index level, 62% of silicon nitride and 69% of PEEK achieved composite clinical success at 2 years (p = 0.64). At 2 years follow-up, there was no difference in revision surgery of the index level between silicon nitride and PEEK. However, patient treated with silicon nitride were operated more frequently at the adjacent level (N = 6) than patients who had implanted PEEK (N = 3). The complaints of these patients at follow-up visits and their perceived recovery scores were most likely influenced by the development of adjacent segment symptoms. In all cases, these patients had evidence of degeneration at the adjacent level, but no related symptoms at the time of the index procedure. Possibly, the initial clinical presentation was already based on symptomatology of both levels which could also explain difference in intermediate outcome measures. In addition, the silicon nitride cages were parallel in design while the PEEK cages had 3° of lordosis. It has been hypothesized that the parallel cages might present a theoretical disturbance of the sagittal balance which could explain the early presentation of adjacent level disease in the silicon nitride patients.

Microporous materials to fill cages are an attractive concept since no autograft harvest or additional expense for cage filler materials is needed. Trabecular metal made from porous tantalum has received extensive testing, but has not fared well as a stand-alone cage material because it lacks strength (leading to fragmentation) and its high radio-opacity and metallic distortion interferes with imaging [33]. Silicon nitride spacers, however, did not suffer from these problems. There were no device integrity issues and imaging was not affected by the silicon nitride product.

Animal studies [11] of silicon nitride implants have shown that there is no foreign body encapsulation as is noted with PEEK cages [9]. This attribute apparently makes the material more bacteriostatic. In our study, one infection of a silicon nitride spacer was successfully debrided without spacer removal, resulting in a successful clinical outcome and fusion. While infections are rare and therefore difficult to study, the bacteriostatic properties of silicon nitride implants may allow patients to recover from inadvertent wound contamination without implant removal. This possibility will only be proven by collection of a large amount of patient data through a registry or meta-analysis.

The design of the CASCADE trial had several limitations. The moderate sample size restricted the amount of subgroup analysis that could be performed. The selection of PEEK cages with autograft harvested from osteophytes as a control group is not the most widely used control in ACDF studies; many US studies incorporate allograft blocks with supplemental fixation as the control group. However, the CASCADE clinical trial represents the worst-case scenario because autograft results in higher fusion rates than allograft. Finally, the study was supported financially by the company Amedica that is the manufacturer of silicon nitride. Every effort was made to eliminate bias in the study design, protocol, and management of the study. Independent Clinical Research Organization (CRO) managed the study together with the principal investigator’s institution, the radiographic measurements were also performed by an independent organization employing their radiologists and yet another independent unit was used to perform statistical analysis. With those precautions, the authors have implemented reasonable procedure to minimize bias.

In conclusion, patients with symptomatic herniated disc or spondylosis treated with anterior cervical discectomy and interbody fusion using silicon nitride or PEEK reported similar recovery rates. There was no significant difference in clinical outcome at 24 months, although some intermediate outcome measures were in favor of PEEK but did not reach the level of clinical relevance. Fusion rates of both implants improve over time and no significant difference was seen regarding fusion and subsidence. The primary hypothesis of similarity in NDI improvement between silicon nitride and PEEK has been proven.