Biomechanical analysis of cervical stabilization systems: an assessment of transpedicular screw fixation in the cervical spine

Y Kotani, BW Cunningham, K Abumi, PC McAfee - Spine, 1994 - journals.lww.com
Study Design The biomechanical stability of seven cervical reconstruction methods including
the transpedicular screw fixation was evaluated under four instability patterns. These four …

Adjacent level intradiscal pressure and segmental kinematics following A cervical total disc arthroplasty: an: in vitro: human cadaveric model

AE Dmitriev, BW Cunningham, N Hu, G Sell, F Vigna… - Spine, 2005 - journals.lww.com
Study Design. In vitro investigation of cervical adjacent level intradiscal pressures (IDPs)
following a total disc replacement arthroplasty. Objectives. The current in vitro study was …

Classification of heterotopic ossification (HO) in artificial disk replacement

PC McAfee, BW Cunningham, J Devine, E Williams… - Spine, 2003 - journals.lww.com
There is currently no structured classification system to quantitate heterotopic bone formation
after artificial disk replacement procedures. The purpose of this work was to develop a …

Stability of posterior spinal instrumentation and its effects on adjacent motion segments in the lumbosacral spine

…, K Kaneda, K Abumi, PC McAfee, BW Cunningham - Spine, 1998 - journals.lww.com
Study Design. An in vitro biomechanical analysis of three anterior instability patterns was
performed using calf lumbosacral spines. Stiffness of the constructs was compared, and …

Biomechanical analysis of lumbosacral fixation

DH McCord, BW Cunningham, Y Shono… - Lumbar Fusion and …, 1992 - Springer
The lumbosacral junction is perhaps the most difficult portion of the spine in which to obtain
a solid fusion [1–11]. This is particularly true following reductions of spondylolisthesis [12]. …

The Effect of Spinal Destabilization and Instrumentation on Lumbar Intradiscal Pressure: An: In Vitro: Biomechanical Analysis

BW Cunningham, Y Kotani, PS McNulty, A Cappuccino… - Spine, 1997 - journals.lww.com
Study Design. In vitro biomechanical testing was performed in human cadaveric lumbar
spines, using pressure needle transducers to analyze the effects of spinal destabilization and …

1989 Volvo Award in basic science: Device-related osteoporosis with spinal instrumentation

…, KR GURR, KE WARDEN, BW CUNNINGHAM - Spine, 1989 - journals.lww.com
An animal model of anterior and posterior column Instability was developed to allow in vivo
observation of bone remodeling and arthrodesis after spinal instrumentation. After an initial …

Biomechanical evaluation of total disc replacement arthroplasty: an in vitro human cadaveric model

BW Cunningham, JD Gordon, AE Dmitriev, N Hu… - Spine, 2003 - journals.lww.com
Study Design. This in vitro biomechanical study was undertaken to quantify the multidirectional
intervertebral kinematics following total disc replacement arthroplasty compared to …

The effect of spinal implant rigidity on vertebral bone density a canine mode

…, KR GURR, KE WARDEN, BW CUNNINGHAM - Spine, 1991 - journals.lww.com
An animal model of anterior and posterior cojumn instability was developed to allow in vivo
observation of bone remodeling and arthrodesis following spinal instrumentation. After an …

The indications for interbody fusion cages in the treatment of spondylolisthesis: analysis of 120 cases

…, CD Chaput, BG Prybis, IL Fedder, BW Cunningham… - Spine, 2005 - journals.lww.com
Study Design. This study retrospectively examines outcomes of unilateral transforaminal
lumbar interbody fusion (TLIF) with posterior fixation using anterior carbon fiber cages and 360 …