Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Advance Online Publication
    • Archive
  • About Us
    • About ISASS
    • About the Journal
    • Author Instructions
    • Editorial Board
    • Reviewer Guidelines & Publication Criteria
  • More
    • Advertise
    • Subscribe
    • Alerts
    • Feedback
  • Join Us
  • Reprints & Permissions
  • Sponsored Content
  • Other Publications
    • ijss

User menu

  • My alerts

Search

  • Advanced search
International Journal of Spine Surgery
  • My alerts
International Journal of Spine Surgery

Advanced Search

  • Home
  • Content
    • Current Issue
    • Advance Online Publication
    • Archive
  • About Us
    • About ISASS
    • About the Journal
    • Author Instructions
    • Editorial Board
    • Reviewer Guidelines & Publication Criteria
  • More
    • Advertise
    • Subscribe
    • Alerts
    • Feedback
  • Join Us
  • Reprints & Permissions
  • Sponsored Content
  • Follow ijss on Twitter
  • Visit ijss on Facebook
Research ArticleNew Technology

Minimally Invasive Lumbar Interbody Fusion With an Expandable Meshed Allograft Containment Device: Analysis of Subsidence With 12-Month Minimum Follow-Up

John Paul G. Kolcun, George M. Ghobrial, Kenneth M. Crandall, Ken Hsuan-Kan Chang, Giacomo Pacchiorotti and Michael Y. Wang
International Journal of Spine Surgery August 2019, 6044; DOI: https://doi.org/10.14444/6044
John Paul G. Kolcun
1Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, Florida
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
George M. Ghobrial
1Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, Florida
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kenneth M. Crandall
1Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, Florida
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ken Hsuan-Kan Chang
2Department of Neurological Surgery, National Yang-Ming University School of Medicine, Taipei, Taiwan
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Giacomo Pacchiorotti
3Institute of Neurosurgery, University of Rome “La Sapienza,” Rome, Italy
MS
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Y. Wang
1Department of Neurological Surgery, University of Miami Miller School of Medicine, Miami, Florida
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

ABSTRACT

Study design Retrospective case series

Objective Describe subsidence in lumbar interbody fusion using an expandable meshed allograft containment device with 12-month minimum radiographic follow-up.

Background We have previously reported the use of a minimally invasive allograft-filled expandable meshed-bag containment system in the lumbar spine. Subsidence has not been reported with this device.

Methods Consecutive adult patients that underwent 1- or 2-level interbody fusion with at least 1 year of follow-up were included in this study. Preoperative, postoperative, and final follow-up lumbar radiographs were analyzed to measure disc height at the anterior and posterior margins of the disc space, as well as the neuroforaminal height.

Results Forty-one patients were identified, with a mean age of 63.4 years (± 11.8). A total of 61 levels were treated, with successful fusion observed in 54 levels (88.5%). The mean radiographic follow-up was 24.3 months (± 11.2). The mean disc height pre- and postoperatively was 6.9 mm (± 3.2) and 10.1 mm (± 2.9, P < .001), respectively. The mean disc height at final follow-up was 8.3 mm (± 2.4). Average disc height subsidence was 1.8 mm (± 1.7, P < .001). Overall, average disc height increased by a net 1.3 mm (± 2.5, P < .001). The mean neuroforaminal height pre- and postoperatively was 18.0 mm (± 3.3) and 20.7 mm (± 3.6, P < .001), respectively. The mean neuroforaminal height at final follow-up was 19.2 mm (± 3.4). Average neuroforaminal height subsidence was 1.3 mm (± 3.4, P = .012). Overall, average neuroforaminal height increased by a net 1.7 mm (± 2.8, P = .004). No significant difference in subsidence was observed between 1- and 2-level surgeries.

Conclusion An expandable allograft containment system is a feasible alternative for lumbar interbody fusion. Due to its biologic and mechanical nature, the surgeon using such constructs should account for an anticipated average of 18% loss of interbody height due to subsidence during the bony remodeling/fusion process.

  • lumbar interbody fusion
  • transforaminal lumbar interbody fusion
  • minimally invasive surgery
  • interbody device
  • subside

Footnotes

  • Disclosures and COI: The senior author (M.Y.W.) serves as a consultant for Depuy Spine, Aesculap Spine, JoiMax, and K2M; receives royalties from Children's Hospital of Los Angeles, Depuy Spine, Springer Publishing, and Quality Medical Publishing; holds stocks in Innovative Surgical Devices and Spinicity; and has grants from the Department of Defense. There are no other potential conflicts of interest to report. The authors have no personal, financial, or institutional interest in any of the drugs, materials, or devices described in this article. No funding was received for this research.

  • The device that is the subject of this manuscript is being evaluated as part of an ongoing FDA-approved investigational protocol (IDE) or corresponding national protocol for lumbar interbody fusion. This device is currently FDA-approved for human use in vertebroplasty.

  • All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. For this type of study, formal consent is not required. This article does not contain any studies with animals performed by any of the authors.

  • ©International Society for the Advancement of Spine Surgery
Next
Back to top

In this issue

International Journal of Spine Surgery: 19 (S2)
International Journal of Spine Surgery
Vol. 19, Issue S2
1 Apr 2025
  • Table of Contents
  • Index by author

Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on International Journal of Spine Surgery.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Minimally Invasive Lumbar Interbody Fusion With an Expandable Meshed Allograft Containment Device: Analysis of Subsidence With 12-Month Minimum Follow-Up
(Your Name) has sent you a message from International Journal of Spine Surgery
(Your Name) thought you would like to see the International Journal of Spine Surgery web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Minimally Invasive Lumbar Interbody Fusion With an Expandable Meshed Allograft Containment Device: Analysis of Subsidence With 12-Month Minimum Follow-Up
John Paul G. Kolcun, George M. Ghobrial, Kenneth M. Crandall, Ken Hsuan-Kan Chang, Giacomo Pacchiorotti, Michael Y. Wang
International Journal of Spine Surgery Aug 2019, 6044; DOI: 10.14444/6044

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Minimally Invasive Lumbar Interbody Fusion With an Expandable Meshed Allograft Containment Device: Analysis of Subsidence With 12-Month Minimum Follow-Up
John Paul G. Kolcun, George M. Ghobrial, Kenneth M. Crandall, Ken Hsuan-Kan Chang, Giacomo Pacchiorotti, Michael Y. Wang
International Journal of Spine Surgery Aug 2019, 6044; DOI: 10.14444/6044
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • High Uptake Detection for Spinal Degenerative Changes: A Comparison Between Bone Scintigraphy and Single Photon Emission Computed Tomography Combined With High-Resolution Computed Tomography
  • Accuracy of Pedicle Screw Placement Using the ExcelsiusGPS Robotic Navigation Platform: An Analysis of 728 Screws
  • A Network Meta-Analysis Comparing the Efficacy and Safety of Pedicle Screw Placement Techniques Using Intraoperative Conventional, Navigation, Robot-Assisted, and Augmented Reality Guiding Systems
Show more New Technology

Similar Articles

Keywords

  • lumbar interbody fusion
  • transforaminal lumbar interbody fusion
  • minimally invasive surgery
  • interbody device
  • subside

Content

  • Current Issue
  • Latest Content
  • Archive

More Information

  • About IJSS
  • About ISASS
  • Privacy Policy

More

  • Subscribe
  • Alerts
  • Feedback

Other Services

  • Author Instructions
  • Join ISASS
  • Reprints & Permissions

© 2025 International Journal of Spine Surgery

International Journal of Spine Surgery Online ISSN: 2211-4599

Powered by HighWire