Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Advance Online Publication
    • Archive
  • About Us
    • About ISASS
    • About the Journal
    • Author Instructions
    • Editorial Board
    • Reviewer Guidelines & Publication Criteria
  • More
    • Advertise
    • Subscribe
    • Alerts
    • Feedback
  • Join Us
  • Reprints & Permissions
  • Sponsored Content
  • Other Publications
    • ijss

User menu

  • My alerts

Search

  • Advanced search
International Journal of Spine Surgery
  • My alerts
International Journal of Spine Surgery

Advanced Search

  • Home
  • Content
    • Current Issue
    • Advance Online Publication
    • Archive
  • About Us
    • About ISASS
    • About the Journal
    • Author Instructions
    • Editorial Board
    • Reviewer Guidelines & Publication Criteria
  • More
    • Advertise
    • Subscribe
    • Alerts
    • Feedback
  • Join Us
  • Reprints & Permissions
  • Sponsored Content
  • Follow ijss on Twitter
  • Visit ijss on Facebook
Research ArticleComplications

Operative Field Debris Often Rises to the Level of the Surgeon's Face Shield During Spine Surgery: Are Orthopedic Space Suits a Reasonable Solution?

CHRISTOPHER R. COOK, TARA GASTON, BARRETT WOODS, FABIO OROZCO, ALVIN ONG and KRIS RADCLIFF
International Journal of Spine Surgery December 2019, 13 (6) 501-506; DOI: https://doi.org/10.14444/6067
CHRISTOPHER R. COOK
1Orthopedic Spine Surgery Fellow, Kaiser Permanente Oakland Medical Center, Berkeley, California
DO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
TARA GASTON
2Orthopedic Surgery Resident, Rowan SOM
DO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
BARRETT WOODS
3Rothman Institute, Philadelphia, Pennsylvania
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
FABIO OROZCO
3Rothman Institute, Philadelphia, Pennsylvania
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
ALVIN ONG
3Rothman Institute, Philadelphia, Pennsylvania
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
KRIS RADCLIFF
3Rothman Institute, Philadelphia, Pennsylvania
MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

ABSTRACT

Background: The present study intended to identify debris in the spine surgical field that frequently rises to the level of the surgeon's face during several different elective spine procedures. Unlike other areas of orthopedic surgery where infection risk is of high concern, in spine surgery the surgical team usually uses a nonsterile face mask instead of a protective space suit with a sterile face shield. It is possible that blood or bone burr particles striking the surgeon's face mask represent a potential source of infection if they ricochet back into the operative field.

Methods: We reviewed 46 consecutive, elective spine surgeries between May 2015 and August 2015 from a single-surgeon practice. For each surgery, every member of the surgical team wore sterile (space suit) personal protective equipment. After each procedure, the face shield was carefully inspected by 2 members of the surgical team to identify patient blood, tissue, or bone burr dust present on the face shield.

Results: The rate of surgeon face shield debris inspected for each case overall was 38/46 (83%). The rate of first assistant face shield debris inspected per case was 16/46 (35%). The scrub technician had a 0% rate of face mask debris on inspection. The highest debris exposure rates occurred with transforaminal lumbar interbody fusions (100%), open laminectomy and fusions (100%), and anterior cervical discectomy and fusions 43/46 (93%).

Conclusions: There is a high rate of blood and tissue debris contact that occurs during spine surgery, and it is procedure dependent. Spine surgeons may consider using sterile shields particularly in high-risk cases to protect themselves and their patients.

Level of Evidence: 4.

  • space suit
  • surgical site infection
  • face shield
  • eye protection
  • contamination
  • sterility
  • debris

INTRODUCTION

Surgical protective equipment, including scrubs, gloves, and face masks have a dual purpose. The equipment protects patients from wound contamination, as well as serves to protect the surgical team from exposure to patient-specific pathogens. Blood or tissue debris from the surgical field can and frequently does land on the protective equipment, including nonsterile surgical loupes and facemasks, exposing the surgical team to these pathogens. Additionally, some of this material may ricochet off the unsterile protective equipment and reflect onto the operative field, leading to legitimate contamination. Such contamination is particularly likely to occur in spine surgery as surgeons often lean into and over the surgical wounds to access deeper structures.

In other areas of surgery, particularly in joint arthroplasty, where aerosolization of blood, bone burr dust, and tissue debris are common, “space suits” have emerged to create a sterile surface across the surgeon's face and neck. Sir John Charnley designed the body exhaust system (BES) with the hope to isolate the surgical site from operating room personnel. The BES was designed as a negative-pressure system with intake and outtake tubing blowing air away from the surgical site, in hopes to keep any bacterial shedding that does occur away from the field. Routine use of the BES began after the publication of a large multicenter prospective randomized study by Lidwell et al1 in 1982. This study showed that, when combined with an ultraclean-air system, incidence of joint sepsis was approximately 25% of operations performed with conventional ventilation.1 The BES tubing was later replaced by the less cumbersome surgical helmet system (SHS), consisting of a portable helmet and hood. Today, this SHS, or what is commonly referred to as the orthopedic “space suit,” is used almost uniformly in orthopedic joint replacement surgery. These suits require specialized ventilated helmets and clear facial coverings. Traditionally, such space suits are not utilized in spine surgery due to difficulty with light illumination and potential reflection of light from the facial covering. Recently, a new helmet/space suit system was developed that is lightweight and features an integrated, adjustable headlight (Figures 1a–c). The integrated headlight offers a comparable illumination to the headlights commonly worn in spine surgery. The sterile face shield and attached hood covers the surgeon's face (including loupes), chin, and neck.

Figure 1
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1

Lateral (a), oblique (b), and axial (c) images of a space suit with integrated headlight. The face shield is far enough anterior that it does not contact or impede the loupes. The orientation of the headlight and relative posterior position of the light relative to the loupes prevent glare by the light from impeding the visualization of the loupes.

The purpose of this study was to evaluate the percentage of spine cases in which debris from the spine surgical field rises to the level of the surgeon's face. Such debris poses an immediate danger to the surgeon and other members of the operative team, and as described above, may reflect a potential source of wound contamination if it ricochets back into the surgical field off a nonsterile facial covering.

METHODS

A collection of 46 consecutive elective spine surgeries between May 2015 and August 2015 were included from a single-surgeon practice. Surgeries included 15 anterior cervical discectomy and fusions (ACDF), 8 posterior cervical discectomy and fusions (PCDF), 4 transforaminal lumbar interbody fusions (TLIF), 6 microdiscectomies, 6 lumbar laminectomies with fusion, and 5 lumbar laminectomies without fusion.

For each surgery, every member of the surgical team wore an orthopedic SHS and gown, with a sterile protective face shield. After each procedure, the face shields of the operative surgeon, first assistant, and scrub technician were carefully examined by 2 independent observers on the surgical team to identify blood, tissue, or burr dust present on the face shield (Figures 2a, 2b). Blood or tissue debris in the upper right corner of the hood (where the handle to adjust the headlight is located) was excluded as it may have been deliberately caused by the surgeon during the case. For the purposes of this study, the presence of tissue debris was considered to represent contamination to the sterile field, carrying with it the potential of becoming an infectious agent.

Figure 2
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2

Frontal view (a) of a face shield inspection following a transforaminal lumbar interbody fusion. There is abundant gross blood splatter visualized on the part of the gown underneath the face shield (covering the surgeon's neck). An oblique view (b) demonstrates that the blood splatter goes up to the top of the face shield corresponding to the surgeon's upper forehead and hairline.

RESULTS

The orthopedic space suits were successfully used in all 46 cases (ie, there were no cases requiring removal of the helmet for completion). There were no complications specific to the helmet that were identified (eg, fogging, discomfort, unavailability, or the inability to accommodate the loupes beneath them). The overall rate of blood and/or tissue debris on the operative surgeon's face shield was 38/46 (83%). The overall rate of blood and/or tissue debris on the first assistant's face shield was 16/46 (35%). The face shield of the scrub technician was not found to have blood or tissue debris in any of the cases (0%).

There were differences in the rate of tissue debris on the face shields between specific procedures. The highest rates occurred with TLIF (100%), open lumbar laminectomy and fusion (100%), and ACDF 43/46 (93%). Of all the cases in which debris was identified, 16 included blood and 14 had bone burr dust, and most cases had dual presence of both. Debris was noted most often in cases that involved the use of a burr, osteotome, or an interbody cage.

DISCUSSION

There is a great deal of biological debris that reaches the level of the surgeon's face during spine surgery. The likelihood of facial debris reflecting from the operative field and onto the surgeon's face is procedure-dependent. Procedures that rely upon a high rate of high speed burr utilization, osteotome bone resection, or interbody cage impaction tend to have the highest rate of face shield debris. Theoretically, in surgeries in which space suits are not used, some of the debris may ricochet from the surgeon's mask and/or loupes, and back into the operative field, introducing a contaminant. Based upon the results in this study, we recommend that spine surgeons consider using these suits, particularly in high-risk cases for the protection of both patient and surgical team.

Intraoperative contamination has been shown to be a serious, inevitable problem that is specific to spine surgery. There is a time-dependent, procedure-independent rate of contamination of the surgical field in most spine surgeries.2,3 Surgical implants and instruments have also been demonstrated to become contaminated in a progressive, time-dependent manner in spine surgery.4,5 The posterior elements themselves (spinous processes, lamina, facets) have even been demonstrated to become contaminated in a time-dependent manner.6–8 Contamination can occur after both simple and complex spinal surgery,9 and has been demonstrated to occur more frequently at the surgical field than at a control location in the operating room, such as at an air conditioner vent or near the doorway.10 Although there has been a substantial amount of research on the treatment of intrawound contamination to prevent infection,11–13 including the use of irrigation14–17 and topical antibiotics,18,19 there has been much less research examining the causes and prevention of intraoperative contamination. Previous studies have also demonstrated that specific tools frequently utilized in spine surgery create aerosolized particles and material that can spread and potentially contaminate the entire room. One such tool, the high-speed burr, creates a cloud of blood, irrigation fluid, and bone/tissue debris that travels through the air above the surgical field.20,21 It is our opinion that the use of surgical space suits may mitigate the effects of contamination from these instruments, thereby lowering the overall infection rate.

Weiner and Kilgore22 examined contamination rates of headlamps/loupes and operative microscopes in 70 lumbar microdiscectomies. Contamination was determined by bacterial growth on blood agar plates placed in the center of the surgical field through a 2-stage air sample/settle technique. It was found that both the headlamp/loupe interface and microscope grew out statistically significant more bacteria than a control group (most common organism being coagulase negative Staphylococcus). Our results may shed some light on the mechanism of eyewear and microscope contamination, as there was a high rate of splash contamination at the level of surgeons' eyewear. Another study by Butt et al23 examined bacterial contamination of samples from the nose pad and earpieces of eyeglasses worn by orthopedic surgeons during surgery. The investigators reported contamination by both Staphylococcus epidermidis and Staphylococcus aureus. They attributed contamination to saline irrigation splash, as well as eyewear accidentally falling into the surgical field.23

Davies et al24 investigated the rate of splash contamination on a surgeon's mask and wrap-around protective eyewear in a single-surgeon prospective study over a 1-year period. Recorded blood and body fluid splash contamination rates were found to be 45% on the surgeon's eyewear, and 24% on the surgeon's mask.24 In comparison to the study in 2007 by Davies et al,24 it would appear that splash contamination rates in this current study are twice that of those reported in the Davies et al24 study. However, the surgeries examined in the Davies et al24 study were various vascular surgeries, which by their nature do not involve work with a bur, osteotome, or the more aggressive instruments used in orthopedic spine surgery. The operations in the 2007 study that most closely compare with the operations performed in this current study were below-knee and above-knee amputations, which did incur a 100% rate of splash contamination on either the glasses or mask worn during the surgery. When looking at these types of procedures specifically, it would appear that the data from this current study match the results found in the Davies et al24 study.

Even in situations in which the surgeon's mask and loupes are clean, debris from the surgical field can become contaminated due to contact with sweat on the surgeon's face.25 Mills et al26 looked at contamination of the surgical site from sweat on the surgeons' face. Normal skin flora was grown out in the sweating phase, demonstrating that exposed regions of the surgeon's face and mask can contribute to contamination of the sterile field.26 Other studies using fluorescent particles have demonstrated a reduction in the exposure of surgeon-fomites onto the surgical field with the use of surgical space suits.27 The sterile face shields on these space suits likely help to prevent contaminants from the surgeon's face (eg, sweat and hair) from reaching the level of the sterile field.

There is a dual advantage of utilizing surgical space suits in spine surgery with regards to preventing surgical team contact with a patient's blood and/or tissue debris. Previous studies have demonstrated that standard surgical eyewear, including loupes, do not confer 100% protection from contamination of surgeon conjunctive during simulated femoral osteotomy.28 The face shields used in this study would presumably confer 100% splash protection from patient biomaterial reaching the surgical team's face and eyes. The surgical team reported no instances of direct contamination of the face or eyes during data collection.

A potential problem with surgical space suits is contamination of the surgical field from a positive pressure outflow of material from the surgeon via unsealed areas in the suit. Young et al29 investigated the potential of contamination via protective suits. Investigators found that contamination, as measured by migration of fluorescent powder applied to the surgeon's hands prior to gown and gloving, was increased with the use of body protective suits compared with standard sterile gowns. Migration of fluorescent powder was greatest at the flexor surfaces of the surgeon's arms and at the level of the sleeve cuff and glove interval, with the dominant hand having a greater amount.29,30 Of note, there was no obvious contamination in the gown-glove interface seen in study.

Limitations to this study include a smaller number of cases performed, and the lack of direct quantification of infection as cultures of any face shield contaminant were not collected. Although tissue debris collected on or near the face mask poses an immediate danger to the surgical team, the real area of interest clinically is the theoretical chance of wound contamination, and ultimately a surgical site infection. The authors recognize that not all cases of wound contamination cause surgical site infection, as well as the fact that adjuvant methods, such as irrigation and topical antibiotics, reduce the rate of surgical site infection. Contamination as well is not necessarily associated with a biological state of infection, as this implies the presence of a microorganism causing damage to body tissue. The authors understand that surgical site infection is a multifactorial process that does not always occur due to bacterial inoculation of the surgical site during surgery. However, the results of this study provide compelling, intuitive evidence of a simple, modifiable risk factor. Although only gross, macroscopic contamination of the face shields was assessed, it is not unreasonable to suspect that contamination of face shields on a microscopic level was just as prevalent in the collected cases. The addition of space suits in this study were not found to severely impact the overall cost of the procedure itself, nor did it limit the operating surgeon during the surgery with the sole exception that it was impossible to use an operating microscope. The senior surgeon uses loupe magnification exclusively. Surgical loupes (3.5×) were worn under the space suits in all cases in this study, and there was no impingement of the loupes on the face shield. At our institution, the average cost of a space suit is approximately $65 US currency (disposable). Additional costs include the helmet and reusable batteries that are reused between cases. However, the reusable helmets are used often in orthopedic surgery so, in our case, there was not a specific expenditure for a helmet purchase. We acknowledge, however, that these results are applicable for open surgeries only without the use of an operating microscope. We suspect that an operating microscope would significantly reduce the surgeon's face shield contamination and ricochet of material back into the operative field. Additionally, we suspect that minimally invasive, tubular surgeries may reduce the exposure to the surgeon's face. We hypothesize that the ergonomics of the surgeon's head position contribute to the lower infection rate observed in minimally invasive spine surgery compared with open surgery.

With the advent of newer, more minimally invasive procedures (ie, tubular spine surgeries), this may also significantly decrease the need for sterile protective shields as these procedures are more contained in their general field of view. Follow-up studies are needed to comment more regarding this question.

In conclusion, wearing a protective, sterile space suit may be efficacious in at least some spinal surgeries to reduce exposure of the surgical team to tissue debris. It is probable that these suits also reduce contamination of the operative field; however, additional controlled, randomized studies are needed to expound upon this. Furthermore, relevant clinical outcomes, such as postoperative surgical site infections and revision surgeries are an important focus for future research endeavors.

Footnotes

  • Disclosures and COI: The authors have no financial conflict with regards to the manufacturers of the orthopedic body suits utilized. No funds were received in support of this work.

  • ©International Society for the Advancement of Spine Surgery
  • This manuscript is generously published free of charge by ISASS, the International Society for the Advancement of Spine Surgery. Copyright © 2019 ISASS.

REFERENCES

  1. 1 .↵
    1. Lidwell OM,
    2. Lowbury EJ,
    3. Whyte W, et al.
    Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. Br Med J (Clin Res Ed). 1982;285:10–14.
    OpenUrlAbstract/FREE Full Text
  2. 2 .↵
    1. Hosseini P,
    2. Mundis GM Jr.,
    3. Eastlack R, et al.
    Do longer surgical procedures result in greater contamination of surgeons' hands? Clin Orthop Relat Res. 2016;474(7):1707–1713.
    OpenUrlCrossRefPubMed
  3. 3 .↵
    1. Shiono Y,
    2. Watanabe K,
    3. Hosogane N, et al.
    Sterility of posterior elements of the spine in posterior correction surgery. Spine (Phila Pa 1976). 2012;37(6):523–526.
    OpenUrl
  4. 4 .↵
    1. Meneske G,
    2. Kuscu, F,
    3. Suntur BM, et al.
    Evaluation of the time-dependent contamination of spinal implants: prospective randomized trial. Spine (Phila Pa 1976). 2015;40(16):1247–1251.
    OpenUrl
  5. 5 .↵
    1. Bible JE,
    2. O'Neill KR,
    3. Crosby CG, et al.
    Implant contamination during spine surgery. Spine J. 2013;13(6):637–640.
    OpenUrl
  6. 6 .↵
    1. Ahn DK,
    2. Park HS,
    3. Kim TW, et al.
    The degree of bacterial contamination while performing spine surgery. Asian Spine J. 2013;7(1):8–13.
    OpenUrl
  7. 7 .
    1. Pumberger M,
    2. Bürger J,
    3. Strube P, et al.
    Unexpected positive cultures in presumed aseptic revision spine surgery using sonication. Bone Joint J. 2019;101-B(5):621–624.
    OpenUrl
  8. 8 .↵
    1. Nandyala SV,
    2. Schwend RM.
    Prevalence of intraoperative tissue bacterial contamination in posterior pediatric spinal deformity surgery. Spine (Phila Pa 1976). 2013;38(8):E482–E486.
    OpenUrl
  9. 9 .↵
    1. Gelalis ID,
    2. Arnaoutoglou CM,
    3. Politis AN, et al.
    Bacterial wound contamination during simple and complex spinal procedures. A prospective clinical study. Spine J. 2011;11(11):1042–1048.
    OpenUrlCrossRefPubMed
  10. 10 .↵
    1. Cook TM,
    2. Piatt CJ,
    3. Barnes S, et al.
    The impact of supplemental intraoperative air decontamination on the outcome of total joint arthroplasty: a pilot analysis. J Arthroplasty. 2019;34(3):549–553.
    OpenUrl
  11. 11 .↵
    1. Anderson PA,
    2. Savage JW,
    3. Radcliff K, et al.
    Prevention of surgical site infection in spine surgery. Neurosurgery. 2017;80(3S):S114–S123.
    OpenUrl
  12. 12 .
    1. Radcliff K,
    2. Morrison WB,
    3. Kepler C, et al.
    Distinguishing pseudomeningocele, epidural hematoma, and postoperative infection on postoperative MRI. Clin Spine Surg. 2016;29(9):E471–E474.
    OpenUrl
  13. 13 .↵
    1. Radcliff KE,
    2. Neusner AD,
    3. Milhouse PW, et al.
    What is new in the diagnosis and prevention of spine surgical site infections. Spine J. 2015;15(2):336–347.
    OpenUrlCrossRefPubMed
  14. 14 .↵
    1. Ahn DK,
    2. Lee S,
    3. Moon SH, et al.
    Bulb syringe and pulsed irrigation: which is more effective to remove bacteria in spine surgeries? Clin Spine Surg. 2016;29(1):34–37.
    OpenUrl
  15. 15 .
    1. Chang FY,
    2. Chang MC,
    3. Wang ST, et al.
    Can povidone-iodine solution be used safely in a spinal surgery? Eur Spine J. 2006;15(6):1005–1014.
    OpenUrlPubMed
  16. 16 .
    1. Tomov M,
    2. Mitsunaga L,
    3. Durbin-Johnson B, et al.
    Reducing surgical site infection in spinal surgery with betadine irrigation and intrawound vancomycin powder. Spine (Phila Pa 1976). 2015;40(7):491–499.
    OpenUrl
  17. 17 .↵
    1. Savage JW,
    2. Anderson PA.
    An update on modifiable factors to reduce the risk of surgical site infections. Spine J. 2013;13(9):1017–1029.
    OpenUrl
  18. 18 .↵
    1. Sweet FA,
    2. Roh M,
    3. Sliva C.
    Intrawound application of vancomycin for prophylaxis in instrumented thoracolumbar fusions: efficacy, drug levels, and patient outcomes. Spine (Phila Pa 1976). 2011;36(24):2084–2088.
    OpenUrl
  19. 19 .↵
    1. Devin CJ,
    2. Chotai S,
    3. McGirt MJ, et al.
    Intrawound vancomycin decreases the risk of surgical site infection after posterior spine surgery-a multicenter analysis. Spine (Phila Pa 1976). 2018;43(1):65–71.
    OpenUrl
  20. 20 .↵
    1. Nogler M,
    2. Lass-Flörl C,
    3. Ogon M, et al.
    Environmental and body contamination through aerosols produced by high-speed cutters in lumbar spine surgery. Spine (Phila Pa 1976). 2001;26(19):2156–2159.
    OpenUrl
  21. 21 .↵
    1. Nogler M,
    2. Lass-Flörl C,
    3. Wimmer C, et al.
    Aerosols produced by high-speed cutters in cervical spine surgery: extent of environmental contamination. Eur Spine J. 2001;10(4):274–277.
    OpenUrlCrossRefPubMed
  22. 22 .↵
    1. Weiner BK,
    2. Kilgore WB.
    Bacterial shedding in common spine surgical procedures: headlamp/loupes and the operative microscope. Spine (Phila Pa 1976). 2007;32(8):918–920.
    OpenUrl
  23. 23 .↵
    1. Butt U,
    2. Saleem U,
    3. Yousuf K, et al.
    Infection risk from surgeons' eyeglasses. J Orthop Surg (Hong Kong). 2012;20(1):75–77.
    OpenUrlCrossRef
  24. 24 .↵
    1. Davies CG,
    2. Khan MN,
    3. Ghauri AS, et al.
    Blood and body fluid splashes during surgery – the need for eye protection and masks. Ann R Coll Surg Engl. 2007;89(8):770–772.
    OpenUrlCrossRefPubMed
  25. 25 .↵
    1. Wright AD.
    Trapping the surgeon's sweat. Br Med J. 1952;1:1197.
    OpenUrlFREE Full Text
  26. 26 .↵
    1. Mills SJ,
    2. Holland DJ,
    3. Hardy AE.
    Operative field contamination by the sweating surgeon. Aust N Z J Surg. 2000;70(12):837–839.
    OpenUrlCrossRefPubMed
  27. 27 .↵
    1. McGovern PD,
    2. Albrecht M,
    3. Khan SK, et al.
    The influence of surgical hoods and togas on airborne particle concentration at the surgical site: an experimental study. J Orthop Sci. 2013;18(6):1027–1030.
    OpenUrl
  28. 28 .↵
    1. Mansour AA,
    2. Even JL,
    3. Phillips S, et al.
    Eye protection in orthopaedic surgery. An in vitro study of various forms of eye protection and their effectiveness. J Bone Joint Surg Am. 2009;91(5):1050–1054.
    OpenUrlAbstract/FREE Full Text
  29. 29 .↵
    1. Young SW,
    2. Chisholm C,
    3. Zhu M.
    Intraoperative contamination and space suits: a potential mechanism. Eur J Orthop Surg Traumatol. 2014;24(3):409–413.
    OpenUrl
  30. 30 .↵
    1. Fraser JF,
    2. Young SW,
    3. Valentine KA, et al.
    The gown-glove interface is a source of contamination: a comparative study. Clin Orthop Relat Res. 2015;473:2291–2297.
    OpenUrl
PreviousNext
Back to top

In this issue

International Journal of Spine Surgery
Vol. 13, Issue 6
1 Dec 2019
  • Table of Contents
  • Index by author

Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on International Journal of Spine Surgery.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Operative Field Debris Often Rises to the Level of the Surgeon's Face Shield During Spine Surgery: Are Orthopedic Space Suits a Reasonable Solution?
(Your Name) has sent you a message from International Journal of Spine Surgery
(Your Name) thought you would like to see the International Journal of Spine Surgery web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Operative Field Debris Often Rises to the Level of the Surgeon's Face Shield During Spine Surgery: Are Orthopedic Space Suits a Reasonable Solution?
CHRISTOPHER R. COOK, TARA GASTON, BARRETT WOODS, FABIO OROZCO, ALVIN ONG, KRIS RADCLIFF
International Journal of Spine Surgery Dec 2019, 13 (6) 501-506; DOI: 10.14444/6067

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Operative Field Debris Often Rises to the Level of the Surgeon's Face Shield During Spine Surgery: Are Orthopedic Space Suits a Reasonable Solution?
CHRISTOPHER R. COOK, TARA GASTON, BARRETT WOODS, FABIO OROZCO, ALVIN ONG, KRIS RADCLIFF
International Journal of Spine Surgery Dec 2019, 13 (6) 501-506; DOI: 10.14444/6067
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • ABSTRACT
    • INTRODUCTION
    • METHODS
    • RESULTS
    • DISCUSSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Postmyelography Acute Paraplegia in Patients With Spinal Cord Stimulators: Case Series and Review of Literature
  • Spinopelvic Fixation Using an Osseointegrative Implant: Analysis of Postmarket Surveillance to Determine the Failure Rate
  • Association of Elevated Perioperative Blood Glucose With Complications and Postoperative Outcomes Following Traumatic Spine Surgery
Show more Complications

Similar Articles

Keywords

  • space suit
  • surgical site infection
  • face shield
  • eye protection
  • contamination
  • sterility
  • debris

Content

  • Current Issue
  • Latest Content
  • Archive

More Information

  • About IJSS
  • About ISASS
  • Privacy Policy

More

  • Subscribe
  • Alerts
  • Feedback

Other Services

  • Author Instructions
  • Join ISASS
  • Reprints & Permissions

© 2025 International Journal of Spine Surgery

International Journal of Spine Surgery Online ISSN: 2211-4599

Powered by HighWire